Plan Review Details - Permit 11030563
Plan Review Stops For Permit 11030563
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-04-19 Cont ID  
Sent By jwitmer Date 2011-04-19 Time 07:49 Rev Time 0.77
Received By jwitmer Date 2011-04-18 Time 15:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-04-01 Cont ID  
Sent By jwitmer Date 2011-04-01 Time 12:58 Rev Time 0.55
Received By jwitmer Date 2011-04-01 Time 12:35 Sent To  
Notes
2011-04-01 13:20:34BUILDING PLAN REVIEW
 PERMIT: 11030563
 ADD: 400 N FLAGLER # 1806
 CONT: A D SABA ENTERPRISES
 TEL: (561)307-5358
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET A-3 SLIDING GLASS DOOR # 8 UNIT SIZE 206'X93".
 IT APPEARS THIS IS A TRUE SLIDING DOOR. THE PLANS DO
 NOT INDICATE ANY TERRACE ON THE OPPOSITE SIDE OF THE
 OPENING, PLEASE INDICATE COMPLIANCE WITH 2007/2009
 FBC-B 2406.3(7) HAZARDOUS LOCATIONS.
  
 2) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING,
 PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING
 REPORTS ARE AS FOLLOWS:
 2A) SINGLE HUNG WINDOW
 2B) PICTURE WINDOW
 2C) SUBMITTED SLIDDING GLASS DOOR INTERNATIONAL IMPACT,
 TITAN 120 SERIES W/ REINFORCEMENT SMALL MISSILE NOA
 09-0127.15
 SHEET 1 OF 5 PANEL WIDTH GREATER THAN 42" AND HEIGHT OF
 96 INCHES CHART HIGHLIGHTED( GLASS OPTION# 1, INTERLOCK
 E3 EXCEEDS CHART PLEASE REVIEW OPTIONS.
 2D) SUBMITTED INNOVATIVE HORIZONTAL SLIDDER WINDOW NOA
 09-0707.03 SHEEET 1 OF 5 SERIES 2062 HIGHLIGHTED -100
 PSI DOES NOT MEET THE REQUIRED -105.8 WINDOW # 5.
  
 3) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 4) SHEET -3 THE ARCHITECT OF RECORD HAS THE WRONG
 EXPOSURE SHEET A-3 THE ENGINEER OF RECORD DOES HAVE THE
 RIGHT WIND CRITERIA.
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-03-29 Cont ID  
Sent By rlecky Date 2011-03-29 Time 11:53 Rev Time 0.00
Received By rlecky Date 2011-03-29 Time 07:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-03-31 Cont ID  
Sent By wjolin Date 2011-03-31 Time 11:13 Rev Time 0.00
Received By wjolin Date 2011-03-31 Time 10:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-04-19 Cont ID  
Sent By jwitmer Date 2011-04-19 Time 07:49 Rev Time 0.00
Received By jwitmer Date 2011-04-14 Time 14:36 Sent To  
Notes
2011-04-14 14:38:15GAVE TO HAROLD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-06 Cont ID  
Sent By lmartine Date 2011-04-05 Time 10:46 Rev Time 0.00
Received By lmartine Date 2011-03-22 Time 10:43 Sent To  
Notes
2011-03-22 10:43:42B18

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-04-18 Cont ID  
Sent By hmoser Date 2011-04-18 Time 14:09 Rev Time 0.00
Received By hmoser Date 2011-04-18 Time 13:42 Sent To  
Notes
2011-04-18 14:15:51PASS PROVISO
 REFER TO SECTION 601.4 BALANCED RETURN AIR.2007 FBC(M)
 REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEM FOR FAN
 SHUTDOWN.
 REFER TO SECTION 606.4.1 INSTALLATION OF DETECTORS.
 SHALL BE CONNECTED
 FIE ALARM SYSTEM 2007 FBC (M)
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-03-28 Cont ID  
Sent By hmoser Date 2011-03-28 Time 12:23 Rev Time 0.00
Received By hmoser Date 2011-03-28 Time 09:54 Sent To  
Notes
2011-03-28 12:40:57PLANS DENIED
 REFER TO SECTION 601.4 2007 FBC (M) BALANCED RETURN AIR
 .
 REFER TO SECTION 606.2.1 2007 FBC (M) SUPPLY SYSTEM. IF
 DUCT DETECTORS ARE NOT INSTALLED PROVIDE A LETTER FROM
 THE MANUFACTURE'S ENGINEER SAYING THAT IN NO SHAPE OR
 FORM WILL THE AIR HANDLER PRODUCE MORE THAN 2000 CFM.
 REFER TO SECTION 606.3 INSTALLATION 2007 FBC (M)
 REFER TO SECTION 602.2.1 MATERIALS EXPOSED WITH IN
 PLENUMS, MATERIALS WITH IN PLENUMS SHALL BE
 NONCOMBUSTIBLE. DOOR SCHEDULE SHOWS A WOOD DOOR.
 REFER TO SECTION 306 2007 FBC (M) ACCESS TO EQUIPMENT
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-04-01 Cont ID  
Sent By lwagner Date 2011-04-01 Time 14:19 Rev Time 0.00
Received By lwagner Date 2011-04-01 Time 14:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2011-04-05 Cont ID  
Sent By aaponte Date 2011-04-05 Time 09:04 Rev Time 0.15
Received By aaponte Date 2011-04-05 Time 09:04 Sent To  
Notes
2011-04-05 09:04:45INTERIOR WORK ONLY. COMPLETE RENOVATION OF A
 RESIDENTIAL UNIT.