Plan Review Details - Permit 11030499
| Plan Review Stops For Permit 11030499 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-14 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-14 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-07 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-07 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2011-04-11 17:01:05 | LINK TO SAMPLE INSTALLATION SCHEDULE: | | | | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | | | 2011-04-07 10:28:36 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE KEY PLAN INCORRECTLY LISTS ASCE 7-98 AND | | | EXPOSURE CATEGORY B. PLEASE CORRECT. | | | | | | 2) SUBMIT 2 COPIES OF AN INSTALLATION SCHEDULE FOR THE | | | ACCORDION SHUTTERS. SPECIFY THE OPENING PRESSURES, THE | | | MOUNTING METHOD, THE SPANS, GLASS SEPARATION, ANCHOR | | | TYPES, ANCHOR SPACING, ETC. THE FORM IS AVAILABLE ON | | | THE CONSTRUCTION SERVICES WEBSITE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-30 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-03-30 |
Time |
08:10 |
Sent To |
Z |
|
| Notes |
| 2011-03-30 09:13:09 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE COMPONENT AND CLADDING PRESSURE TABLES THAT WERE | | | SUBMITTED ARE NOT ACCEPTABLE. THE BUILDING IS LOCATED | | | IN EXPOSURE CATEGORY C NOT B. THE BUILDINGS HAS A MEAN | | | ROOF HEIGHT OF WELL ABOVE 60'. THE 2007 FLORIDA | | | BUILDING CODE AND ASCE 7-05 ARE THE EDITIONS IN EFFECT | | | AT THIS TIME. PLEASE PROVIDE CORRECT ENGINEERING. | | | | | | 2) THE KEY PLAN INCORRECTLY LISTS ASCE 7-98 AND | | | EXPOSURE CATEGORY B. PLEASE CORRECT. | | | | | | 3) SUBMIT 2 COPIES OF AN INSTALLATION SCHEDULE FOR THE | | | ACCORDION SHUTTERS. SPECIFY THE OPENING PRESSURES, THE | | | MOUNTING METHOD, THE SPANS, GLASS SEPARATION, ANCHOR | | | TYPES, ANCHOR SPACING, ETC. THE FORM IS AVAILABLE ON | | | THE CONSTRUCTION SERVICES WEBSITE. | | | | | | 4) ACCORDING TO THE MIAMI DADE WEBSITE THE PRODUCT | | | APPROVAL FOR THE TROPICAL DEPRESSION SHUTTER INDUSTRIES | | | ACCORDION SHUTTERS HAS A CLOSED FILE STATUS. PLEASE | | | SUBMIT A CURRENT PRODUCT APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-07 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-05 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2011-04-06 07:14:54 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-30 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-03-17 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2011-03-17 15:43:04 | MISC. 1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2011-04-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-30 |
Time |
10:30 |
Rev Time |
0.05 |
| Received By |
aaponte |
Date |
2011-03-31 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy