Plan Review Details - Permit 11030468
Plan Review Stops For Permit 11030468
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-03-28 Cont ID  
Sent By kconrad Date 2011-03-28 Time 11:05 Rev Time 0.00
Received By kconrad Date 2011-03-28 Time 10:58 Sent To  
Notes
2011-03-28 11:12:11AN FIRE INVESTIGATION WAS PERFORMED PURSUANT TO THE
 WPBFRD'S REQUEST. OBSERVED THAT THE INTERIOR UNIT WILL
 BE REQUIRED TO BE COMPLETELY DEMOLISHED AND DRYWALL
 REPLACED. ADVISED THE CONTRACTOR TO OBTAIN MEP PERMITS
 AS WELL AND ADDITIONAL INFORMATION/DOCUMENTATION MAY BE
 REQUIRED DURING ROUTINE FIELD INSPECTIONS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-04-12 Cont ID  
Sent By rlecky Date 2011-04-12 Time 09:50 Rev Time 0.00
Received By rlecky Date 2011-04-12 Time 09:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-03-30 Cont ID  
Sent By rlecky Date 2011-03-30 Time 07:43 Rev Time 0.00
Received By rlecky Date 2011-03-30 Time 07:43 Sent To  
Notes
2011-03-30 07:43:40PROVIDE AN ELECTRIC PLAN WITH SCOPE OF WORK. PROVIDE
 TAMPER RESISTANT RECEPTACLES, GFCI PROTECTED
 RECEPTACLES, AFCI CIRCUIRTS, AND SMOKE DETECTORS,
 KITCHEN CIRCUITS ETC., IN ACCORDANCE WITH THE 2008 NEC.
  
  
 ROBERT LECKY, ELECTRICAL PLAN REVIEW. 561-805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-03-31 Cont ID  
Sent By wjolin Date 2011-03-31 Time 10:57 Rev Time 0.00
Received By wjolin Date 2011-03-31 Time 10:57 Sent To  
Notes
2011-03-31 10:57:181441 BRANDYWINE ROAD SUITE 200D
 PERMIT #11030468
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE SMOKE ALARMS PER EXISTING APARTMENT BUILDINGS
 AS REQUIRED IN CHAPTER 31 OF THE FLORIDA FIRE
 PREVENTION CODE NFPA 101.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-05-11 Cont ID  
Sent By hmoser Date 2011-05-11 Time 13:59 Rev Time 0.00
Received By hmoser Date 2011-05-11 Time 07:46 Sent To  
Notes
2011-05-11 07:47:04TO H. MOSER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-11 Cont ID  
Sent By rmcdouga Date 2011-05-11 Time 07:46 Rev Time 0.00
Received By rmcdouga Date 2011-04-04 Time 14:35 Sent To  
Notes
2011-04-04 14:35:52B--2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-04 Cont ID  
Sent By lmartine Date 2011-03-31 Time 14:28 Rev Time 0.00
Received By lmartine Date 2011-03-17 Time 13:47 Sent To  
Notes
2011-03-17 13:48:01INCOMING SENT TO B-2 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-05-11 Cont ID  
Sent By hmoser Date 2011-05-11 Time 13:59 Rev Time 0.00
Received By hmoser Date 2011-05-11 Time 12:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-03-29 Cont ID  
Sent By hmoser Date 2011-03-29 Time 13:24 Rev Time 0.00
Received By hmoser Date 2011-03-29 Time 13:07 Sent To  
Notes
2011-03-29 13:27:35NO MECHANICAL PLANS SUBMITTED CALLED CONTRACTOR THEY
 ARE GOING TO SUBMIT PLANS.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-04-12 Cont ID  
Sent By lwagner Date 2011-04-12 Time 11:02 Rev Time 0.00
Received By lwagner Date 2011-04-12 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-03-30 Cont ID  
Sent By lwagner Date 2011-03-30 Time 10:30 Rev Time 0.00
Received By lwagner Date 2011-03-30 Time 10:29 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2011-03-28 Cont ID  
Sent By eschneid Date 2011-03-28 Time 13:53 Rev Time 0.50
Received By eschneid Date 2011-03-28 Time 13:53 Sent To  
Notes
2011-03-28 13:54:01PASSED W/PROVISO
  
 1) ALL EXTERIOR AND PATIO RECONSTRUCTION SHALL MATCH
 ORIGINAL.
  
  


Account Summary | Usage Policy | Privacy Policy