| Plan Review Stops For Permit 11030458 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-06-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-29 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-29 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2011-06-29 11:20:08 | 2007 FBC W/2009 REVISIONS | | | 2ND REVIEW | | | DENIED BY BUILDING | | | | | | 1) THE VALUE FOR THE WORK STATED ON THE APPLICATION IS | | | TOO LOW. FBC 108.3 CITY AMENDMENTS STATES THAT FOR | | | PERMITTING PURPOSES THE VALUATION INCLUDES THE | | | STRUCTURAL, ELECTRICAL, INTERIOR FINISH, DESIGN FEES, | | | LABOR AND MATERIAL COSTS, OVERHEAD AND PROFIT AS A | | | CONTRACTOR WOULD CHARGE. PLEASE CORRECT THE VALUE. | | | | | | 2) THE COMPONENT AND CLADDING PRESSURES FOR THE WINDOWS | | | AND DOORS WILL NEED TO BE INCREASED TO COMPLY WITH | | | EXPOSURE CATEGORY C. THE PRESSURES ON THE REVISED PLANS | | | ARE INCORRECT. | | | | | | 3) SUBMIT TWO COPIES OF ENERGY CODE COMPLIANCE FORMS | | | FOR THE ADDITION. THE FORMS ARE REQUIRED TO BE SIGNED | | | AND DATED BY THE PREPARER AND THE OWNER/AGENT. | | | | | | 4) THE PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM | | | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-28 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-03-28 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2011-03-28 15:53:47 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE VALUE FOR THE WORK STATED ON THE APPLICATION IS | | | TOO LOW. FBC 108.3 CITY AMENDMENTS STATES THAT FOR | | | PERMITTING PURPOSES THE VALUATION INCLUDES THE | | | STRUCTURAL, ELECTRICAL, INTERIOR FINISH, DESIGN FEES, | | | LABOR AND MATERIAL COSTS, OVERHEAD AND PROFIT AS A | | | CONTRACTOR WOULD CHARGE. PLEASE CORRECT THE VALUE. | | | | | | 2) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C PER | | | FBC R301.2.1.4.3. PLEASE CORRECT. | | | | | | 3) THE COMPONENT AND CLADDING PRESSURES FOR THE WINDOWS | | | AND DOORS WILL NEED TO BE INCREASED TO COMPLY WITH | | | EXPOSURE CATEGORY C. | | | | | | 4) SUBMIT TWO COPIES OF ENERGY CODE COMPLIANCE FORMS. | | | THE FORMS ARE REQUIRED TO BE SIGNED AND DATED BY THE | | | PREPARER AND THE OWNER/AGENT. | | | | | | 5) SHOW COMPLIANCE WITH FBC R703.6.3 WHICH REQUIRES A | | | BOND BREAK BETWEEN THE REQUIRED WATER RESISTIVE BARRIER | | | AND THE STUCCO ON THE EXTERIOR WALLS. | | | | | | 6) SHOW COMPLIANCE WITH ASTM C 1063 SECTION 7.11.5 | | | WHICH REQUIRES A FOUNDATION WEEP SCREED AT THE BOTTOM | | | OF ALL FRAMED EXTERIOR STUCCO WALLS. | | | | | | 7) THE PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM | | | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-07-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-07-07 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-07-07 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-03-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-03-17 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-03-17 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2011-03-17 12:49:46 | ADDITIONAL RECEPTACLES ARE REQUIRED. THEY SHALL BE | | | SPACED SO THAT AT NO POINT ALONG THE FLOOR IN ANY WALL | | | IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. NEC | | | 210.52 (A)(2). | | | ALL NEW RECEPTACLES WITHIN THE DWELLING SHALL BE | | | PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER. | | | NEC 210-12 (B) | | | ALL NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC | | | 406.11 | | | AN ELECTRICAL PERMIT IS REQUIRED FOR THIS WORK. | | | | | | ROBERT LECKY, ELECTRICAL PLANS REVIEW, 561-805-6718 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-07-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-07-07 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-06-27 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2011-06-27 17:42:20 | SENT TO SHELF R1 FOR BUILDING AND ELECTRICAL REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-04-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-04-01 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-17 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2011-03-17 08:13:21 | INCOMING SENT TO R-1 BOX. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2011-06-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-29 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-29 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2011-03-25 15:47:58 | NEEDS IMPACT FEE REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-04-01 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-04-01 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2011-04-01 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|