Plan Review Details - Permit 11030446
| Plan Review Stops For Permit 11030446 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-03-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-03-29 |
Time |
08:47 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-03-29 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2011-03-29 08:48:03 | BUILDING PROVISO: | | | 1406.2.2 ARCHITECTURAL TRIM. IN BUILDINGS | | | OF TYPE I, II, III AND IV CONSTRUCTION THAT | | | DO NOT EXCEED THREE STORIES OR 40 FEET | | | (12 192 MM) IN HEIGHT ABOVE GRADE PLANE, | | | EXTERIOR WALL COVERINGS SHALL BE PERMITTED | | | TO BE CONSTRUCTED OF WOOD WHERE PERMITTED | | | BY SECTION 1405.4 OR OTHER EQUIVALENT | | | COMBUSTIBLE MATERIAL. | | | | | | 1405.4 WOOD VENEERS. WOOD VENEERS ON | | | EXTERIOR WALLS OF BUILDINGS OF TYPE I, II, III | | | AND IV CONSTRUCTION SHALL BE NOT LESS THAN 1 INCH | | | (25 MM) NOMINAL THICKNESS, 0.438-INCH | | | (11.1 MM) EXTERIOR HARDBOARD SIDING OR | | | 0.375-INCH (9.5 MM) EXTERIOR-TYPE WOOD | | | STRUCTURAL PANELS OR PARTICLEBOARD AND SHALL | | | CONFORM TO THE FOLLOWING: | | | TABLE 1405.2 | | | MINIMUM THICKNESS OF WEATHER | | | COVERINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-03-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-03-22 |
Time |
07:50 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2011-03-22 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2011-03-22 08:02:32 | BUILDING PROVISO: | | | 1406.2.2 ARCHITECTURAL TRIM. IN BUILDINGS | | | OF TYPE I, II, III AND IV CONSTRUCTION THAT | | | DO NOT EXCEED THREE STORIES OR 40 FEET | | | (12 192 MM) IN HEIGHT ABOVE GRADE PLANE, | | | EXTERIOR WALL COVERINGS SHALL BE PERMITTED | | | TO BE CONSTRUCTED OF WOOD WHERE PERMITTED | | | BY SECTION 1405.4 OR OTHER EQUIVALENT | | | COMBUSTIBLE MATERIAL. | | | | | | 1405.4 WOOD VENEERS. WOOD VENEERS ON | | | EXTERIOR WALLS OF BUILDINGS OF TYPE I, II, III | | | AND IV CONSTRUCTION SHALL BE NOT LESS THAN 1 INCH | | | (25 MM) NOMINAL THICKNESS, 0.438-INCH | | | (11.1 MM) EXTERIOR HARDBOARD SIDING OR | | | 0.375-INCH (9.5 MM) EXTERIOR-TYPE WOOD | | | STRUCTURAL PANELS OR PARTICLEBOARD AND SHALL | | | CONFORM TO THE FOLLOWING: | | | TABLE 1405.2 | | | MINIMUM THICKNESS OF WEATHER | | | COVERINGS | | | | | | | | | FAILED: PLANS APPEAR TO BE CODE COMPLIANT WITH PROVISO, | | | PLANS ARE STAMPED: | | | WILL ENTER A PASSED ONCE CONTRACTOR LICENSURE IS | | | VERIFIED. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-03-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-03-24 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-15 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2011-03-17 10:51:04 | ****************EXPEDITED***************** | | | 3/16/11 | | 2011-03-16 11:08:37 | C22 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-03-23 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-03-23 |
Time |
15:28 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2011-03-23 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
|