Plan Review Details - Permit 11030446
Plan Review Stops For Permit 11030446
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-03-29 Cont ID  
Sent By jwitmer Date 2011-03-29 Time 08:47 Rev Time 0.55
Received By jwitmer Date 2011-03-29 Time 08:47 Sent To  
Notes
2011-03-29 08:48:03BUILDING PROVISO:
 1406.2.2 ARCHITECTURAL TRIM. IN BUILDINGS
 OF TYPE I, II, III AND IV CONSTRUCTION THAT
 DO NOT EXCEED THREE STORIES OR 40 FEET
 (12 192 MM) IN HEIGHT ABOVE GRADE PLANE,
 EXTERIOR WALL COVERINGS SHALL BE PERMITTED
 TO BE CONSTRUCTED OF WOOD WHERE PERMITTED
 BY SECTION 1405.4 OR OTHER EQUIVALENT
 COMBUSTIBLE MATERIAL.
  
 1405.4 WOOD VENEERS. WOOD VENEERS ON
 EXTERIOR WALLS OF BUILDINGS OF TYPE I, II, III
 AND IV CONSTRUCTION SHALL BE NOT LESS THAN 1 INCH
 (25 MM) NOMINAL THICKNESS, 0.438-INCH
 (11.1 MM) EXTERIOR HARDBOARD SIDING OR
 0.375-INCH (9.5 MM) EXTERIOR-TYPE WOOD
 STRUCTURAL PANELS OR PARTICLEBOARD AND SHALL
 CONFORM TO THE FOLLOWING:
 TABLE 1405.2
 MINIMUM THICKNESS OF WEATHER
 COVERINGS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-03-22 Cont ID  
Sent By jwitmer Date 2011-03-22 Time 07:50 Rev Time 0.50
Received By jwitmer Date 2011-03-22 Time 07:30 Sent To  
Notes
2011-03-22 08:02:32BUILDING PROVISO:
 1406.2.2 ARCHITECTURAL TRIM. IN BUILDINGS
 OF TYPE I, II, III AND IV CONSTRUCTION THAT
 DO NOT EXCEED THREE STORIES OR 40 FEET
 (12 192 MM) IN HEIGHT ABOVE GRADE PLANE,
 EXTERIOR WALL COVERINGS SHALL BE PERMITTED
 TO BE CONSTRUCTED OF WOOD WHERE PERMITTED
 BY SECTION 1405.4 OR OTHER EQUIVALENT
 COMBUSTIBLE MATERIAL.
  
 1405.4 WOOD VENEERS. WOOD VENEERS ON
 EXTERIOR WALLS OF BUILDINGS OF TYPE I, II, III
 AND IV CONSTRUCTION SHALL BE NOT LESS THAN 1 INCH
 (25 MM) NOMINAL THICKNESS, 0.438-INCH
 (11.1 MM) EXTERIOR HARDBOARD SIDING OR
 0.375-INCH (9.5 MM) EXTERIOR-TYPE WOOD
 STRUCTURAL PANELS OR PARTICLEBOARD AND SHALL
 CONFORM TO THE FOLLOWING:
 TABLE 1405.2
 MINIMUM THICKNESS OF WEATHER
 COVERINGS
  
  
 FAILED: PLANS APPEAR TO BE CODE COMPLIANT WITH PROVISO,
 PLANS ARE STAMPED:
 WILL ENTER A PASSED ONCE CONTRACTOR LICENSURE IS
 VERIFIED.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-03-24 Cont ID  
Sent By lmartine Date 2011-03-24 Time 10:39 Rev Time 0.00
Received By lmartine Date 2011-03-15 Time 11:08 Sent To  
Notes
2011-03-17 10:51:04****************EXPEDITED*****************
 3/16/11
2011-03-16 11:08:37C22

Review Stop Z ZONING
Rev No 1 Status P Date 2011-03-23 Cont ID  
Sent By eschneid Date 2011-03-23 Time 15:28 Rev Time 0.25
Received By eschneid Date 2011-03-23 Time 15:28 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved