| Plan Review Stops For Permit 11030438 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-04-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-04-21 |
Time |
09:29 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-04-21 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-03-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-03-31 |
Time |
12:10 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2011-03-29 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2011-03-31 12:14:37 | BUILDING PROVISO: | | | EXERCISE BATHROOM & SHOWER: | | | 1) TOILET TO COMPLY WITH HEIGHT REQUIREMENT 11-4.16.3 | | | 17" TO 19" MEASURED FROM THE TOP OF THE SEAT. | | | | | | 2) GRAB RAILS TO COMPLY WITH 11-4.16.4. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-04-05 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-04-05 |
Time |
15:04 |
Rev Time |
2.00 |
| Received By |
rlecky |
Date |
2011-04-05 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-04-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2011-04-19 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2011-04-19 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-04-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2011-04-04 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2011-04-04 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2011-04-04 15:38:41 | 777 SOUTH FLAGLER DRIVE, 12TH FLOOR | | | PERMIT NUMBER 11030438 | | | | | | 1. DEMOLITION, RENOVATION, AND CONSTRUCTION TO COMPLY | | | WITH NFPA 241. | | | | | | 2. DUSTPROOF WALLS SHALL NOT BE CONSTRUCTED OF | | | MATERIALS THAT ARE FLAMMABLE OR COMBUSTIBLE. | | | | | | 3. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM SYSTEMS REMODELING. | | | | | | 4. EXISTING HORIZONTAL AND VERTICAL FIRE SEPARATIONS | | | ARE TO BE MAINTAINED. | | | | | | 5. PLEASE PROVIDE FLAMESPREAD DETAILS FOR FABRIC | | | CEILING PANELS DISPLAYED ON SHEET A5.2. | | | | | | 6. THE INSTALLATION OF CARD READERS SHALL NOT INTERFERE | | | WITH ANY EXITING. | | | | | | 7. PLEASE PROVIDE FLAMESPREAD DETAILS FOR WOOD VENEER | | | WALL PANELS. | | | | | | 8. THE INSTALLATION OF SOFFITS SHALL NOT INTERFERE WITH | | | THE OPERATION OF ANY FIRE SPRINKLER HEADS. | | | | | | 9. ALL NEW FIRE DAMPERS ARE TO BE DROP TESTED TO ENSURE | | | PROPER OPERATION. | | | | | | 10. CLOSET AND OFFICE NEAR RECEPTION DESK APPEARS TO BE | | | ABSENT OF FIRE SPRINKLER HEADS ON SHEET FS2. | | | | | | | | | DENIED | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-04-28 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-04-12 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2011-04-07 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2011-03-15 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-04-28 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-04-28 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-04-07 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-04-07 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-04-07 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2011-04-07 12:55:08 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. IF EXHAUST FIRE DAMPER IS NEW, A FIRE AND SMOKE | | | DAMPER IS REQUIRED AT THE EXHAUST SHAFT PENETRATION PER | | | FBC-M 607.5.5. | | | | | | 2. FIRE DAMPER AND FIRE/SMOKE DAMPER SYMBOLS ON THIS | | | PAGE DO NOT CORRESPOND WITH THOSE USED IN THE SYMBOL | | | LEGEND ON PAGE M1. PLEASE CORRECT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-04-19 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-04-19 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-04-19 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-03-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-03-30 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-03-30 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2011-03-30 09:51:12 | FBC 2007 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET P-2 & P-3 SHOW A SINK INSIDE THE WET VENT FOR | | | THE WATER CLOSET. PLEASE SHOW THE SINK DOWNSTREAM OF | | | THE WET VENT. | | | 909.1 HORIZONTAL WET VENT PERMITTED. ANY COMBINATION OF | | | FIXTURES WITHIN TWO BATHROOM GROUPS LOCATED ON THE SAME | | | FLOOR LEVEL IS PERMITTED TO BE VENTED BY A HORIZONTAL | | | WET VENT. THE WET VENT SHALL BE CONSIDERED THE VENT FOR | | | THE FIXTURES AND SHALL EXTEND FROM THE CONNECTION OF | | | THE DRY VENT ALONG THE DIRECTION OF THE FLOW IN THE | | | DRAIN PIPE TO THE MOST DOWNSTREAM FIXTURE DRAIN | | | CONNECTION TO THE HORIZONTAL BRANCH DRAIN. ONLY THE | | | FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO | | | THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2011-05-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-05-09 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-05-09 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|