Plan Review Details - Permit 11030363
Plan Review Stops For Permit 11030363
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-04-29 Cont ID  
Sent By shill Date 2011-04-29 Time 17:18 Rev Time 0.00
Received By shill Date 2011-04-29 Time 17:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-03-16 Cont ID  
Sent By shill Date 2011-03-16 Time 16:03 Rev Time 0.00
Received By shill Date 2011-03-16 Time 16:03 Sent To  
Notes
2011-03-16 16:03:51****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PROVIDE DESIGN OCCUPANT LOAD FBC1004.1.
  
 2. INCLUDE THE FOLLOWING IN THE PROJECT INFORMATION:
 BUILDING TYPE, FBC CHAPTER
 SPRINKLERED OR NON SPRINKLERED BUILDING
  
 3. REVISE PLAN TO SHOW DISTANCE BETWEEN MASSAGE ROOM 5
 AND THE PROPOSED PARTITION (WHICH APPEARS TO BE A CHECK
 OUT COUNTER), FBC1014.4.1.
  
 4. IT APPEARS THAT AN EXTERIOR DOOR IS TO BE REPLACED
 WITH STOREFRONT. SPECIFY DESIGN PRESSURES FBC 1609 AND
 PROVIDE PRODUCT APPROVAL FOR THE STOREFRONT AND
 MULLIONS IF APPLICABLE.
  
 5. A BENCH IS SHOWN IN FRONT OF THE STOREFRONT. IS THE
 STOREFRONT FULL HEIGHT AS IT IS REPLACING A DOOR, WITH
 THE BENCH BLOCKING THE WINDOW, OR WILL THERE BE WALL
 INFILL? PROVIDE A DETAIL FBC1609.
  
 6. PROVIDE A DETAIL FOR THE STEAM ROOM AND SHOWER WALLS
 FBC2509. INCLUDE INSULATION FBC 13 101.4.1.1.
  
 7. SPECIFY DOOR TYPE FOR THE STEAM ROOM, FBC 13
 101.4.1.1.
  
 8. REVISE PLAN TO DESIGNATE W/C USE (SUCH AS UNISEX,
 PRIVATE, MENS, WOMENS, ETC.) FBC 11. ONE W/C IS BEING
 ALTERED BUT DOES NOT PROVIDE TURNING RADIUS. SEE FBC
 11-4.1.6(2).
  
 9. SHOW PULL SIDE CLEARANCE (MINIMUM 18INCHES) FOR
 RECEPTION INTERIOR DOOR, FBC FIGURE 11 25.
  
 10. THE STEAM ROOM DOOR OBSTRUCTS EXITING FROM THE
 SHOWER, FBC 1005.2 AND EGRESS THROUGH THE STEAM ROOM
 DOOR IS NOT ORIENTED TOWARDS THE EXIT.
  
 11. MECHANICAL VENTILATION IS REQUIRED IN THE STEAM
 ROOM FBC 1203.4.2.1.
  
 12. PROVIDE A DETAIL FOR WALL FRAMING FBC 106, FBC 6.
  
 13. PROVIDE INFORMATION REGARDING ACCESSIBLE ELEMENTS
 FBC 11-4.1.6(2).
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-05-02 Cont ID  
Sent By rlecky Date 2011-05-02 Time 11:04 Rev Time 0.00
Received By rlecky Date 2011-05-02 Time 10:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-03-14 Cont ID  
Sent By rlecky Date 2011-03-14 Time 14:17 Rev Time 0.00
Received By rlecky Date 2011-03-14 Time 12:28 Sent To  
Notes
2011-03-14 14:18:361. GFCI PROTECTION IS REQUIRED FOR GENERAL PURPOSE
 RECEPTACLES LOCATED IN THE LUNCH ROOM. NEC 210.8(B)
 2. SHOW THE LOCATION OF THE PANELBOARD. NEC 110.26,
 408.18
  
 ROBERT LECKY, ELECTRICAL PLANS REVIEW, 561-805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-04-28 Cont ID  
Sent By wjolin Date 2011-04-28 Time 16:03 Rev Time 0.00
Received By wjolin Date 2011-04-28 Time 15:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-03-24 Cont ID  
Sent By wjolin Date 2011-03-24 Time 14:46 Rev Time 0.00
Received By wjolin Date 2011-03-24 Time 14:15 Sent To  
Notes
2011-03-24 14:46:132260 PALM BEACH LAKES BOULEVARD, SUITE #215
 PERMIT #11030363
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE ADDRESS ON THE COVER SHEET AND THE ADDRESS IN THE
 TITLEBLOCK DO NOT MATCH.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS
 OF NFPA 241.
  
 THE RELEASING MECHANISM ON ALL DOORS SHALL OPEN THE
 DOOR WITH NOT MORE THAN ONE RELEASING OPERATION. THE
 RELEASING MECHANISM SHALL HAVE AN OBVIOUS METHOD OF
 OPERATION THAT IS READILY OPERATED UNDER ALL LIGHTING
 CONDITIONS. THE RELEASING DEVICE SHOULD BE CAPABLE OF
 BEING OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE
 TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST
 TO OPERATE PER SECTION 7.2.1.5.9 OF NFPA 101 FLORIDA
 EDITION 2007.
  
 IDENTIFY POINT OF COMPASS ON FLOOR PLANS.
  
 PROVIDE A ONE HOUR FIRE RATED TENANT SEPARATION WITH
 ADJACENT TENANT SPACE.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-05 Cont ID  
Sent By shill Date 2011-05-05 Time 10:51 Rev Time 0.00
Received By shill Date 2011-04-27 Time 16:46 Sent To  
Notes
2011-04-27 16:46:14B19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-03-30 Cont ID  
Sent By lmartine Date 2011-03-24 Time 16:19 Rev Time 0.00
Received By lmartine Date 2011-03-11 Time 16:30 Sent To  
Notes
2011-03-11 16:35:01*****************EXPEDITED*******************
 B--15

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2011-04-29 Cont ID  
Sent By shill Date 2011-04-29 Time 16:49 Rev Time 0.00
Received By shill Date 2011-04-29 Time 16:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2011-05-05 Cont ID  
Sent By shill Date 2011-05-05 Time 11:01 Rev Time 0.00
Received By shill Date 2011-05-05 Time 10:51 Sent To  
Notes
2011-05-05 10:52:29PROVIDE MECHANICAL PLANS SHOWING ALL PROPOSED WORK WITH
 MECHANICAL PERMIT APPLICATION
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-03-17 Cont ID  
Sent By shill Date 2011-03-17 Time 09:02 Rev Time 0.00
Received By hmoser Date 2011-03-17 Time 09:02 Sent To  
Notes
2011-03-17 09:02:19PLANS DENIED
  
 1. VENITLATION REQUIRED IN STEAM ROOM AND SHOWER, FBC M
 403. VENTILATION NOT SPECIFIED IN THE SHOWER AND NOT
 SPECIFIED OR SHOWN IN THE STEAM ROOM.
  
 2. VENTILATION NOT SHOWN OR SPECIFIED IN THE W/C ROOMS,
 FBC M 403.
  
 3. PLEASE REVIEW PLAN TO PROVIDE MORE INFORMATION
 REGARDING W/C ROOMS, A SMALL SYMBOL FOR SUPPLY IS SHOWN
 IN ONE BUT NOT IN THE NEW ALTERED W/C. PLEASE SHOW ALL
 EXISTING AND PROPOSED NEW SUPPLY FBC M 403.
  
 4. ELECTRIC PLAN SHOWS TWO WATER HEATERS, SHEET M2
 SHOWS ONE. PLEASE CORRELATE. ARE THEY GAS OR ELECTRIC
 WATER HEATERS? FBC M 1002.
  
 PLAN REVIEW BY HAROLD MOSER

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-05-05 Cont ID  
Sent By lwagner Date 2011-05-05 Time 09:05 Rev Time 0.00
Received By lwagner Date 2011-05-05 Time 07:52 Sent To  
Notes
2011-05-05 08:17:01*****PROVISO*****
  
 1. 1002.4 TRAP SEALS. ...WHERE A TRAP SEAL IS SUBJECT
 TO LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL
 BE INSTALLED.
  
 2. 905.4 VERTICAL RISE OF VENT. EVERY DRY VENT SHALL
 RISE VERTICALLY TO A MINIMUM OF 6 INCHES (152 MM) ABOVE
 THE FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED
 FIXTURE BEING VENTED.
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-03-23 Cont ID  
Sent By lwagner Date 2011-03-23 Time 11:21 Rev Time 0.00
Received By lwagner Date 2011-03-22 Time 13:59 Sent To  
Notes
2011-03-23 11:21:15FBC PLUMBING 2007 REVIEW #1
 DENIED:
  
 1. 1002.1 WASHING MACHINE AND FLOOR DRAIN ARE NOT SHOWN
 AS BEING TRAPPED. FLOOR DRAIN REQUIRES A TRAP
 PRIMER.1002.4
  
 2. FBC 106.3.5.1.3 PLEASE INCLUDE HOT AND COLD WATER
 DIAGRAM INCLUDING ALSO STEAM PIPEING.
  
 3. PLEASE SHOW THE LOCATION OF THE EXISTING BOTTLED
 WATER DISPENSER OR ADD THE REQUIRED DRINKING FOUNTAIN
 PER 403.1 MINIMUM FIXTURES.
  
 ****NOTE****
 PLEASE SEE NOTE 8 IN BUILDING REVIEW.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2011-03-31 Cont ID  
Sent By lmartine Date 2011-03-30 Time 16:19 Rev Time 0.00
Received By astelly Date 2011-03-31 Time 13:11 Sent To  
Notes
2011-03-31 13:17:49AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PASSED W/ PROVISO
  
  
 THE CONTRACTOR HAS AGREED TO INFORM THE BUSINESS OWNER
 OF THE FOLLOWING DETERMINATION:
  
 IF THE MASSAGE SERVICES INCLUDE THE MANIPULATION,
 RUBBING, STROKING, KNEADING AND/OR TAPPING OF ANOTHER
 PERSON'S SUPERFICIAL TISSUE ACCOMPANIED BY THE EXPOSURE
 OF SPECIFIED ANATOMICAL AREAS, IT WILL BE CLASSIFIED AS
 AN "ADULT ENTERTAINMENT ESTABLISHMENT" AS DEFINED BY
 PALM BEACH COUNTY'S ADULT ENTERTAINMENT CODE TO WHICH
 THE CITY DEFERS. ADULT ENTERTAINMENT ESTABLISHMENTS ARE
 NOT ALLOWED IN OUR GENERAL COMMERCIAL (GC) ZONING
 DISTRICTS, THE ZONING DISTRICT FOR THE AFOREMENTIONED
 PROJECT. IF IT IS DETERMINED THAT THE BUSINESS DOES
 ENGAGE IN ADULT ENTERTAINMENT ACTIVITIES, THE OWNER
 WILL BE REQUIRED TO CEASE AND DESIST AT THAT LOCATION
 AND MOVE THE BUSINESS TO AN INDUSTRIAL (I) ZONING
 DISTRICT WHERE ADULT ENTERTAINMENT USES ARE ALLOWED
 PROVIDED THAT THEY MEET THE EXTRA REQUIREMENTS (PXR)
 SPECIFIED IN SEC. 94-273(A)(1) OF THE CITY'S ZONING
 CODE.
  
 FURTHERMORE, ALL MASSEUSE AND MASSAGE THERAPISTS WHO
 PRACTICE IN THE BUSINESS WILL BE REQUIRED TO PROVIDE A
 COPY OF THEIR PROFESSIONAL LICENSES WHEN THEY APPLY FOR
 A BUSINESS TAX RECEIPT (AKA OCCUPATIONAL LICENSE).
  