Plan Review Details - Permit 11030300
Plan Review Stops For Permit 11030300
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-04-11 Cont ID  
Sent By jwitmer Date 2011-04-11 Time 13:10 Rev Time 1.50
Received By jwitmer Date 2011-04-11 Time 10:30 Sent To  
Notes
2011-04-11 12:54:06BUILDING PLAN REVIEW
 PERMIT: 11030300
 ADD: 2201 45TH ST- MAIN HOSPITAL
 CONT: M. J. HARRIS, INC
 TEL: (615)499-0183
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) SHEET A2.01D NEW WORK ITEM # 74 DRESSING ROOM
 PLANS ARE UNCLEAR AS TO THE USAGE OF THE DRESSING ROOM,
 IS IT FOR PATIENTS OR FOR WORKERS WITHIN THE HOSPITAL?
 PLEASE IDENTIFY IF THIS DRESSING ROOM IS TO BE FOR
 PATIENTS OR FOR HOSPITAL PERSONAL.
  
 11-4.1.1(3) AREAS USED ONLY BY EMPLOYEES AS WORK AREAS.
 AREAS THAT ARE USED ONLY AS WORK AREAS SHALL BE
 DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH
 DISABILITIES CAN APPROACH, ENTER, AND EXIT THE AREAS.
 THIS CODE DOES NOT REQUIRE THAT ANY AREAS USED ONLY AS
 WORK AREAS BE CONSTRUCTED TO PERMIT MANEUVERING WITHIN
 THE WORK AREA OR BE CONSTRUCTED OR EQUIPPED (I.E., WITH
 RACKS OR SHELVES) TO BE ACCESSIBLE.
  
 1A) DOOR LOCATION (H) BY WALL BEING CUT BACK AND
 LEAVING A 6 INCH PROJECTION.THE DOOR DOES NOT HAVE 18
 INCHES CLEARENCE ON THE LATCH SIDE OF THE DOOR.
 11-4.13.6. PLEASE ALSO REVIEW A4.02 DOOR TYPE (H) IS
 LABELED EITHER A SLIDING OR FOLDING DOOR.
  
 1B) IF THE DRESSING ROOM IN QUESTION IS TO BE FOR
 PATIENT USE THEN THE REQUIREMENTS FOR DRESSING ROOMS
 WILL NEED TO BE REVIEWED 11-4.35 (1-5).
  
 1C) THE PLANS DO NOT INDICATE ANY WORK TO BE COMPLETED
 WITHIN THE LOCKER AREA IF THE LOCKERS ARE TO BE FOR
 PATIENT USAGE THEN REACH RANGES MAY BE A CONCERN,
 REVIEW 11-4.2.5 FOR FORWARD REACH AND 11-4.2.6 FOR SIDE
 REACH.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-04-19 Cont ID  
Sent By rlecky Date 2011-04-19 Time 07:36 Rev Time 0.00
Received By rlecky Date 2011-04-19 Time 07:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-04-12 Cont ID  
Sent By wjolin Date 2011-04-12 Time 13:05 Rev Time 0.00
Received By wjolin Date 2011-04-12 Time 12:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-19 Cont ID  
Sent By jwitmer Date 2011-04-19 Time 15:14 Rev Time 0.00
Received By lmartine Date 2011-03-18 Time 15:14 Sent To  
Notes
2011-03-18 15:18:30INCOMING: PLANS FAILED INCOMING, PLANS DEEMED
 UNIDENTIFYABLE WORK AREAS (5) PROJECTS, ADDRESSES ON
 PLANS DOES NOT MATCH LAND FILE NOR DOES
 CORRESPONDANCE WWITH CONTRACTOR.
  
 CONTRACTOR JOBSITE SUPERINTENDANT BILL
 TEL: 205-718-3186
2011-03-17 10:15:37INCOMING SENT TO C30. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-04-14 Cont ID  
Sent By hmoser Date 2011-04-14 Time 13:13 Rev Time 0.00
Received By hmoser Date 2011-04-14 Time 12:28 Sent To  
Notes
2011-04-14 13:14:32MECHANICAL PLANS ON PLUMBING SHEETS
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-04-08 Cont ID  
Sent By lwagner Date 2011-04-08 Time 10:35 Rev Time 0.00
Received By lwagner Date 2011-04-05 Time 07:57 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2011-04-14 Cont ID  
Sent By eschneid Date 2011-04-14 Time 09:23 Rev Time 0.25
Received By eschneid Date 2011-04-14 Time 09:23 Sent To  
Notes
2011-04-14 09:25:56INTERIOR WORK ONLY. LESS THEN 50% VALUE PLUS CSPD HAS
 APPROVED LANDSCAPE PLAN.