Plan Review Details - Permit 11030180
| Plan Review Stops For Permit 11030180 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-04-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-04-05 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-04-05 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-23 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-23 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2011-03-23 16:32:26 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. ON THE DOOR PRODUCT APPROVAL, MARK THE OPTION | | | PROPOSED. PLEASE NOTE THAT MOST OF THE OPTIONS DO NOT | | | COMPLY WITH THE POSITIVE DESIGN PRESSURE REQUIREMENT. | | | | | | 2. ON THE SHUTTER INSTALLATION SCHEDULE, PLEASE REVISE | | | THE FOLLOWING: | | | | | | SHUTTER CONNECTION MOUNTING TYPE, THIS SHOULD CORRELATE | | | WITH THE ANCHOR CHARTS ON PAGES 10-11 (FOR INSTANCE, | | | WALL MOUNT 3 W/1" BO HEADER, OR FLOOR MOUNT 6, ETC.). | | | PLEASE NOTE THAT YOU HAVE SPECIFIED THE SUBSTRATE AS | | | CONCRETE BLOCK, BUT SOME REQUIRE A CONCRETE SUBSTRATE. | | | | | | 1 1/2" EDGE DISTANCE PROPOSED, SEE NOTE ON PAGE 11 OF | | | THE PRODUCT APPROVAL. EDGE DISTANCE LESS THAN 3 1/2" | | | REQUIRES A FACTOR TO BE APPLIED TO THE ANCHOR SPACING | | | IN THE CHARTS. | | | | | | NOTE THAT 12" SPACING FOR FLOOR MOUNT DOES NOT COMPLY | | | FOR THIS DESIGN PRESSURE, EVEN WITH 3 1/2" EDGE | | | DISTANCE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-14 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-14 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2011-03-14 15:56:38 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL | | | BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE | | | INSTALLATION SCHEDULE, ITEM 2 ABOVE. FBC R301, FBC1609, | | | FBC*106. | | | | | | 3. DESIGN PRESSURES FOR BUILDINGS OVER 60' ARE TO BE | | | DETERMINED BY AN ENGINEER, FS471, FBC1609. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-23 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-17 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-14 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-14 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
|