Plan Review Details - Permit 11030091
Plan Review Stops For Permit 11030091
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-04-01 Cont ID  
Sent By jwitmer Date 2011-04-01 Time 15:19 Rev Time 0.00
Received By jwitmer Date 2011-04-01 Time 15:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-03-10 Cont ID  
Sent By jwitmer Date 2011-03-10 Time 11:59 Rev Time 0.77
Received By jwitmer Date 2011-03-10 Time 10:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-03-29 Cont ID  
Sent By rlecky Date 2011-03-29 Time 12:24 Rev Time 0.00
Received By rlecky Date 2011-03-29 Time 12:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-03-14 Cont ID  
Sent By rlecky Date 2011-03-14 Time 14:57 Rev Time 0.00
Received By rlecky Date 2011-03-14 Time 14:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-03-31 Cont ID  
Sent By wjolin Date 2011-03-31 Time 11:40 Rev Time 0.00
Received By wjolin Date 2011-03-31 Time 11:18 Sent To  
Notes
2011-03-31 11:39:342465 MERCER AVENUE SUITE #101
 PERMIT #11030091
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 EXITING THROUGH WORK ROOMS NOT PERMITTED. ADJUST EXIT
 SIGNS LOCATIONS ON SHEET A3 TO ROUTE TO BREAK ROOM
 EXIT.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-03-15 Cont ID  
Sent By wjolin Date 2011-03-15 Time 16:13 Rev Time 0.00
Received By wjolin Date 2011-03-15 Time 14:02 Sent To  
Notes
2011-03-15 16:13:372465 MERCER AVENUE #101
 PERMIT #11030091
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE/SMOKE BARRIER PROTECT ALL OPENINGS. CHARACTERS
 SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN
 WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15
 FEET ON CENTER. REFERENCE SECTION 8.3.2.4 NFPA 101
 FLORIDA EDITION 2007.
  
 INDICATE THE OCCUPANCY TYPE OF THE ADJACENT TENANT
 SPACE WEST OF THE NEW 1-HOUR FIRE RATED WALL. INDICATE
 HOW EXITING AND EXIT SIGNAGE IS AFFECTED BY THE NEW
 WALL.
  
 ACCESS TO AN EXIT SHALL NOT BE THROUGH A WORK ROOM PER
 SECTION 7.5.2.1 OF NFPA 101 FLORIDA EDITION 2007.
  
 DOORS IN THE MEANS OF EGRESS SHALL OPEN WITH NOT MORE
 THAN ONE RELEASING OPERATION.
  
 NO EMERGENCY LIGHTING HAS BEEN PROVIDED FOR THE WAITING
 ROOM EXIT OR THE TRAINING ROOM EXIT.
  
 PROVIDE FIRE ALARM INITIATION DEVICES AND NOTIFICATION
 APPLIANCES PER NFPA 72 FOR INTERIOR TENANT SPACE.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 INDICATE IF ANY DEMOLITION WORK IS TO BE PERFORMED. ALL
 DEMOLITION WORK TO COMPLY WITH THE REQUIREMENTS OF NFPA
 241.
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND FIRE ALARM SYSTEM.
  
 STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF
 DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-04-01 Cont ID  
Sent By jwitmer Date 2011-04-01 Time 15:18 Rev Time 0.00
Received By jwitmer Date 2011-03-28 Time 13:40 Sent To  
Notes
2011-03-28 13:40:15SENT TO B6.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-01 Cont ID  
Sent By jwitmer Date 2011-03-21 Time 15:18 Rev Time 0.00
Received By jwitmer Date 2011-03-08 Time 13:28 Sent To  
Notes
2011-03-08 13:32:02B--6

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-03-21 Cont ID  
Sent By hmoser Date 2011-03-21 Time 14:52 Rev Time 0.00
Received By hmoser Date 2011-03-21 Time 13:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-03-14 Cont ID  
Sent By lwagner Date 2011-03-14 Time 12:31 Rev Time 0.00
Received By lwagner Date 2011-03-14 Time 12:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2011-03-21 Cont ID  
Sent By lmartine Date 2011-03-21 Time 14:57 Rev Time 0.00
Received By lmartine Date 2011-03-10 Time 13:53 Sent To  
Notes
2011-03-21 14:57:49INTERIOR ONLY, NO CHANGE OF USE


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved