Plan Review Details - Permit 11030010
Plan Review Stops For Permit 11030010
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-03-22 Cont ID  
Sent By rmcdouga Date 2011-03-22 Time 07:26 Rev Time 0.00
Received By rmcdouga Date 2011-03-22 Time 07:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-03-15 Cont ID  
Sent By rmcdouga Date 2011-03-15 Time 07:31 Rev Time 0.00
Received By rmcdouga Date 2011-03-15 Time 07:06 Sent To  
Notes
2011-03-15 09:48:432007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C PER
 FBC R301.2.1.4.3. PLEASE CORRECT.
  
 2) THE COMPONENT AND CLADDING PRESSURES FOR THE WINDOW
 AND DOOR ON SHEET A01 NEED TO BE INCREASED TO REFLECT
 EXPOSURE C.
  
 3) SHOW COMPLIANCE WITH FBC R703.6.3 WHICH REQUIRES A
 BOND BREAK BETWEEN THE EXTERIOR STUCCO AND THE REQUIRED
 WATER RESISTIVE BARRIER.
  
 4) SHOW COMPLIANCE WITH ASTM 1063 REQUIRES A WEEP
 SCREED AT THE BOTTOM OF ALL FRAMED EXTERIOR WALLS BELOW
 THE FLOOR LINE. FBC 703.6
  
 5) SHOW COMPLIANCE WITH FBC R704.1 FOR THE 6 INCH
 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL
 EARTH GRADE FOR INSPECTION FOR TERMITES.
  
 6) PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM BEACH
 COUNTY TO DETERMINE IF IMPACT FEES ARE DUE. THE PLANS
 THAT HAVE BEEN STAMPED BY THE COUNTY AND A COPY OF THE
 PAID RECEIPT ARE REQUIRED TO BE SUBMITTED BEFORE THE
 PERMIT IS ISSUED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-03-07 Cont ID  
Sent By rlecky Date 2011-03-07 Time 15:49 Rev Time 0.00
Received By rlecky Date 2011-03-07 Time 15:30 Sent To  
Notes
2011-03-07 15:50:23REDLINED

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2011-03-01 Cont ID  
Sent By fmittner Date 2011-03-01 Time 10:51 Rev Time 0.00
Received By fmittner Date 2011-03-01 Time 10:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-03-22 Cont ID  
Sent By rmcdouga Date 2011-03-22 Time 07:26 Rev Time 0.00
Received By rmcdouga Date 2011-03-17 Time 09:10 Sent To  
Notes
2011-03-17 09:11:16INCOMING SENT TO R MCD DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-03-15 Cont ID  
Sent By rmcdouga Date 2011-03-15 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2011-03-02 Time 08:13 Sent To  
Notes
2011-03-02 08:13:58R-5

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2011-03-23 Cont ID  
Sent By rmcdouga Date 2011-03-23 Time 11:16 Rev Time 0.00
Received By rmcdouga Date 2011-03-23 Time 11:16 Sent To  
Notes
2011-03-15 10:01:23REVIEW #MU2011-5041

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-03-22 Cont ID  
Sent By rmcdouga Date 2011-03-22 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2011-03-22 Time 07:16 Sent To  
Notes
2011-03-22 07:24:04A MECHANICAL REVISION IS REQUIRED. A DRAWING SHOWING
 THE SIZE OF THE DUCT, THE GRILL SIZE, THE CFM AT THE
 NEW DROP AND HOW IT IS ATTACHED TO THE EXISTING HVAC
 SYSTEM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-03-15 Cont ID  
Sent By rmcdouga Date 2011-03-15 Time 07:35 Rev Time 0.00
Received By rmcdouga Date 2011-03-15 Time 07:35 Sent To  
Notes
2011-03-15 07:41:232007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) SPECIFY THE DUCT SIZE, THE GRILL SIZE AND THE CUBIC
 FEET PER MINUTE OF SUPPLY AIR ON THE PLANS.
  
 2) INDICATE WHAT TYPE/SIZE EXISTING SUPPLY DUCT THE NEW
 WILL BE TIED INTO ON THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2011-03-01 Cont ID  
Sent By fmittner Date 2011-03-01 Time 10:50 Rev Time 0.00
Received By fmittner Date 2011-03-01 Time 10:50 Sent To  
Notes
***NONE***