Plan Review Details - Permit 11020330
| Plan Review Stops For Permit 11020330 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-02-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-22 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-22 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-02-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-16 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-16 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2011-02-16 09:48:28 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW SECOND | | | CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | | | | ENGINEERING CALCULATIONS SUBMITTED: | | | | | | 1- DESIGN PRESSURES SHOWN BY THE ENGINEER FOR ROOF | | | ZONES 1, 2 AND 3 DON'T CORRESPOND TO EXPOSURE "C". | | | REVISE AS REQUIRED. | | | | | | 2- PROVIDE ACTUAL RAS 117 CALCULATIONS TO VERIFY | | | COMPLIANCE WITH RAS 117. CALCULATIONS WERE NOT | | | SUBMITTED. | | | | | | 3- ENGINEER TO IDENTIFY WHICH SPECIFIC APPROVED | | | ASSEMBLY FROM NOA 08-0410.09 SUBMITTED IS GOING TO BE | | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES REQUIRED BY SEC. R301 OF 2007 FLORIDA | | | RESIDENTIAL CODE AND PROPOSED NAIL ENHANCING. | | | | | | 4- ENGINEER'S LETTER REFERS TO POLYGLASS NOA. NOA | | | SUBMITTED IS FOR CERTAIN TEED CORPORATION NOT | | | POLYGLASS. REVISE AS REQUIRED. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-14 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-14 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2011-02-14 13:42:37 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- SPECIFY WHICH APPROVED ASSEMBLY FROM NOA 08-0410.09 | | | SUBMITTED IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 2- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | SUBMITTED. | | | | | | ***NOTES: A)DESIGN PROFESSIONAL DOING THE RAS 117 | | | CALCULATIONS TO TAKE INTO CONSIDERATION THAT ACCORDING | | | TO 2009 REVISIONS SEC. R301.2.1.4.3 OF 2007 FLORIDA | | | RESIDENTIAL CODE THIS BUILDING IS LOCATED ON EXPOSURE | | | "C". | | | | | | B) ASSEMBLIES THAT ARE LIMITED BY GENERAL LIMITATION #9 | | | CAN'T BE USED IN THIS AREA BECAUSE THEY DON'T MEET THE | | | DESIGN PRESSURES AND NAIL ENHANCING IS NOT ALLOWED. SEE | | | GENERAL LIMITATION #9 ON LAST PAGE OF NOA. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-02-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-22 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-22 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-02-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-16 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-16 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-14 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-14 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |