Plan Review Details - Permit 11020297
| Plan Review Stops For Permit 11020297 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-14 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-14 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2011-03-14 08:36:57 | ****PROVISO**** | | | ****REVISION REQUIRED**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | REVISE INSTALLATION SCHEDULE AS FOLLOWS: | | | | | | 1. (COMMENT FROM REVIEW #2) - THE ANCHOR SPACING DOES | | | NOT COMPLY WITH REQUIREMENTS OF THE PRODUCT APPROVAL. | | | FOR INSTANCE, SEE OPENING 1. C2 CONNECTION TYPE, BLOCK | | | SUBSTRATE, -70PSF REQUIRES 4" SPACING, SEE CHART ON | | | SHEET 10. THIS COMMENT APPLIES TO OTHER OPENINGS. | | | PLEASE CHECK ALL AND REVISE INSTALLATION SCHEDULE AS | | | REQUIRED. | | | | | | REVIEW #3 - COMMENT FROM REVIEW #2 PARTIALLY ADDRESSED | | | - SOME OPENINGS (SUCH AS OPENING 1) SPECIFY DIFFERENT | | | ANCHOR SPACING FOR TOP AND BOTTOM ALTHOUGH BOTH | | | CONNECTIONS HAVE THE SAME CONNECTION TYPE, WIND DESIGN | | | PRESSURE, AND SPAN. SEE OPENING 1, 12" SPACING DOES NOT | | | MEET THE REQUIREMENT OF THE PRODUCT APPROVAL FOR 34" | | | SPAN, 2.5" EDGE DISTANCE, BLOCK SUBSTRATE. | | | | | | PLEASE REVISE. PLEASE HAVE THE QUALIFIER VERIFY | | | ACCURACY OF INSTALLATION SCHEDULE PRIOR TO SUBMITTAL. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-03-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-01 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-01 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2011-03-01 14:44:08 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THE ANCHOR SPACING DOES NOT COMPLY WITH REQUIREMENTS | | | OF THE PRODUCT APPROVAL. FOR INSTANCE, SEE OPENING 1. | | | C2 CONNECTION TYPE, BLOCK SUBSTRATE, -70PSF REQUIRES 4" | | | SPACING, SEE CHART ON SHEET 10. THIS COMMENT APPLIES TO | | | OTHER OPENINGS. PLEASE CHECK ALL AND REVISE | | | INSTALLATION SCHEDULE AS REQUIRED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-15 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-02-15 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2011-02-15 14:35:53 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PLEASE PROVIDE MORE INFORMATION AS TO HOW YOU HAVE | | | DETERMINED THAT THE BOTTOM SUBSTRATE IS CONCRETE RATHER | | | THAN FILLED CMU. ALTERNATIVELY, PLEASE REVISE | | | INSTALLATION SCHEDULE FOR BLOCK ON THE BOTTOM. | | | | | | 2. PLEASE EXPLAIN SPANS; HOW CAN SPAN BE THE SAME SIZE | | | AS OPENING WITH A 2.5 INCH EDGE DISTANCE, WALL MOUNT? | | | PLEASE REVISE INSTALLATION SCHEDULE. | | | | | | 3. SEE OPENING 2, ANCHOR SPACING DOES NOT COMPLY WITH | | | CHART IN PRODUCT APPROVAL FOR THIS SPAN AND CONNECTION | | | TYPE. PLEASE REVISE AND CHECK ALL OPENINGS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-14 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-07 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2011-03-07 14:24:58 | SENT TO S. HILL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-02-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-28 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-28 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2011-02-28 11:49:20 | SENT TO S. HILL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-15 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-02-11 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2011-02-11 15:31:17 | TO MISC 1 BOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |