| Plan Review Stops For Permit 11020011 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-03-28 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-03-28 |
Time |
10:01 |
Sent To |
PC |
|
| Notes |
| 2011-03-28 11:29:08 | RESTAMPED PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-03-16 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-03-16 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-14 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-14 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2011-02-14 16:44:27 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) ROOF SHINGLES. | | | | | | B) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | | | C) ACCORDING TO MIAMI-DADE WEBSITE GARAGE DOOR NOA | | | 08-0718.01 WAS SUPERSEDED BY NOA 09-0604.03. PROVIDE | | | CURRENT NOA 09-0604.03. | | | | | | D) PROVIDE NOA FOR JELD WEN SWING DOOR FOR SIZE OF DOOR | | | SPECIFIED ON PLANS. NOA 07-0709.07 SUBMITTED IS FOR | | | 8'-0" HIGH DOORS. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 OF CITY AMENDMENTS TO FBC. | | | | | | 3- SPECIFY ATTIC ACCESS SIZE AND LOCATION ON PLANS AS | | | REQUIRED BY SEC. R807 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 4- CLARIFY HOW IS THE GARAGE GOING TO BE ACCESSED. SITE | | | PLAN DOESN'T SHOW ANY DRIVEWAY AND THE EXISTING | | | CARPORT/STORAGE IS BLOCKING THE ACCESS. | | | | | | 5- SHEET #1: | | | A) UPDATE GENERAL NOTE #1. REFER TO CURRENT CODE 2007 | | | FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | B) REVISE GENERAL NOTE #26. ROOF ZONE #3 ALSO REQUIRES | | | 8D RING SHANK NAILS @ 4"O.C.. SEE SEC. R803.2.3.1 OF | | | 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 6- SECTION "A" ON SHEET #3: | | | A) REVISE VERTICAL REINFORCEMENT SPACING TO MATCH | | | FOUNDATION PLAN. | | | | | | B) SPECIFY FINISH GRADE AS REQUIRED BY SEC. R404.1.6 OF | | | 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 7- TRUSS PACKAGE: | | | A) TRUSS ENGINEER TO PROVIDE ORIGINAL SIGNATURE IN ALL | | | SHEETS AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES. NO | | | RUBBER STAMP. | | | | | | B) ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | TRUSS PACKAGE BEFORE SUBMITTAL TO THIS OFFICE. | | | | | | 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. SEC. 108.3 CITY AMENDMENTS TO FBC. VALUATION TO | | | INCLUDE ALL LABOR, MATERIALS AND ENGINEERING SERVICES. | | | VALUATION WAS UPDATED TO $30,000. PERMIT FEE BALANCE IS | | | $632.70. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-03-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-03-17 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-03-17 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-02-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-02-17 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-02-17 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2011-02-17 13:42:25 | | | | THE SERVICE AS SHOWN WITH A 125 AMP MAIN BREAKER | | | REQUIRES A LARGER CONDUCTOR, GROUND AND CONDUIT. THE #6 | | | ELECTRICAL FEED TO THE 125 AMPERE GARAGE PANEL IS UNDER | | | SIZED. NEC 230.90, 310.16 | | | | | | ALL GENERAL PURPOSE RECEPTACLES WITHIN THE GARAGE | | | INCLUDING THE WORKSHOP AREA MUST BE GFCI PROTECTED. NEC | | | 210.8 | | | | | | ROBERT LECKY, ELECTRICAL PLAN REVIEW, 561-805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-03-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-23 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-03-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-23 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-03-09 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2011-03-09 13:48:27 | INCOMING SENT TO R-10. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-02-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-02-17 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-02-02 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2011-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-03-28 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-03-28 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2011-03-28 11:30:01 | RESTAMPED PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-03-16 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-03-16 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-02-14 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-02-14 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2011-02-14 14:07:08 | RESIDENTIAL (R3) ADDITION, PLUMBING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | | | | PLUMBING RISER DIAGRAM: | | | 1- WET VENTING IS ONLY ALLOWED FOR BATHROOM FIXTURES. | | | SEE SEC. P3108.1 OF THE 2007 FLORIDA RESIDENTIAL CODE | | | AND REVISE AS REQUIRED. | | | | | | 2- CLARIFY WHAT IS "COV" SHOWN ON THE 3" DRAIN. | | | | | | 3- RISER DIAGRAM SHOWS 3" DRAIN TO CONNECT "TO EXISTING | | | SEPTIC". SEPTIC TANKS ARE NOT ALLOWED IN THE CITY. | | | REVISE AS REQUIRED. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2011-03-25 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-03-25 |
Time |
13:39 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2011-03-25 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2011-03-22 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-03-22 |
Time |
10:36 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2011-03-22 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2011-03-22 10:40:12 | FAILED | | | | | | 1) THE SURVEY VERIFIES THAT THE REAR OF THE EXISTING | | | BUILDING (COVERED AREA) EXTENDS FURTHER SOUTH THAN THE | | | SITE PLAN SHOWS. THE PROPOSED ACCESSORY STRUCTURE IS | | | LOCATED WITHIN SIX (6) FEET OF THE PRIMARY STRUCTURE; | | | THEREFORE, THE ACCESSORY STRUCTURE SHALL MET THE | | | REQUIRED PRIMARY STRUCTURE SETBACKS OF TEN (10) FEET | | | FROM THE WEST (SIDE) PROPERTY LINE AND 11 FEET FROM THE | | | SOUTH (REAR) PROPERTY LINE. | | | | | | 2) THERE IS A DISCREPANCY BETWEEN THE SURVEY AND THE | | | AERIAL FOR THE PROPERTY. SURVEY DOES NOT SHOW THE | | | CARPORT/STORAGE ATTACHED TO THE HOUSE. THE APPLICANT | | | HAS ADDITIONALLY STATED THAT THESE STRUCTURES ARE | | | CONNECTED. A CORRECTED SURVEY IS REQUIRED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-02-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-02-16 |
Time |
13:17 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2011-02-16 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2011-02-16 13:34:38 | FAILED | | | | | | 1) PROVIDE TWO COPIES OF A RECENT SURVEY, LESS THAN ONE | | | YEAR OLD, AT THEIR ORIGINAL SCALE. | | | | | | 2) THE SURVEY WILL BE USED TO CLARIFY VISUAL | | | DISCREPANCIES BETWEEN THE SITE PLAN AND THE 2009 | | | AERIAL. | | | | | | 3) ARE THE AREAS SHOWN AS COVERED AND STORAGE ON THE | | | SITE PLAN ENCLOSED SPACE? IF THESE AREAS ARE ENCLOSED | | | AND NOT ATTACHED TO THE RESIDENCE, THEN THEY SHALL BE | | | COUNTED TOWARD THE ACCESSORY STRUCTURE SQUARE FOOTAGE. | | | NOTE A MAXIMUM OF 882 SQUARE FEET OF ACCESSORY | | | STRUCTURE IS ALLOWED ON THE SITE. THE PROPOSED GARAGE | | | IS 825 SQUARE FEET. | | | | | | 4) IS A/C BEING PROVIDED FOR THE PROPOSED GARAGE? IF | | | SO, PROVIDE THE LOCATIONS W/SETBACKS OF THE PROPOSED | | | A/C ON THE SITE PLAN. THE A/C UNIT SETBACKS ARE BASED | | | ON THE PRIMARY STRUCTURE SETBACK REQUIREMENTS. | | | | | | 5) HOW WILL THE GARAGE DOOR BE ACCESSED BY VEHICLES? | | | THERE IS NO ACCESS FROM THE DRIVEWAY TO THE GARAGE | | | DOOR. THIS CAN NOT BE CALLED A GARAGE IF IT CAN NOT BE | | | ACCESSED BY A VEHICLE VIA A DRIVEWAY. ADDITIONALLY, IT | | | MAY NOT HAVE A GARAGE DOOR. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|