| Plan Review Stops For Permit 11010629 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-22 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-21 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2011-03-21 17:41:08 | ****PROVISOS**** | | | ****REVISION REQUIRED**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. ELEVATION CERTIFICATE REQUIRED BEFORE CONCRETE POUR. | | | INCLUDE PROPOSED ELEVATION OF MECHANICAL EQUIPMENT | | | (9.5' PER PLAN). THIS INFORMATION IS REQUIRED TO ALSO | | | BE ON THE SIGNED AND SEALED ELEVATION CERTIFICATE PER | | | FEMA. | | | | | | 2. BOND BREAK REQUIRED FOR STUCCO OVER FRAME WALL FBC R | | | 703.6.3. | | | | | | 3. PROVIDE A DETAIL FOR STAIR AND GUARDRAIL. | | | DETAIL/SHOP DRAWINGS (REVIEWED BY DOR) TO COMPLY WITH | | | FBC R311, R312, R301.5. | | | | | | 4. ROOF NOA PROVIDED 07-0710.05 - FOAM ADHESIVE PRODUCT | | | APPROVAL REQUIRED FOR ROOF. THIS MAY BE SUBMITTED | | | EITHER WITH THE ROOF PERMIT APPLICATION OR WITH A | | | REVISION TO THE MASTER PERMIT. | | | | | | 5. THE TWO SETS OF PRODUCT APPROVAL FOR THE GARAGE DOOR | | | ARE NOT THE SAME. PLEASE DETERMINE WHICH DOOR WILL BE | | | INSTALLED AND SUBMIT PRODUCT APPROVAL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-03 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-02-03 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2011-02-03 17:28:07 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THIS PARCEL IS LOCATED IN A HIGH HAZARD FLOOD ZONE. | | | THE PROPOSED ELEVATION OF 9.15 ON THE SITE PLAN IS | | | NOTED. PLEASE INCLUDE ELEVATION OF MECHANICAL EQUIPMENT | | | AND GARAGE. PROVIDE AN ELEVATION CERTIFICATE, | | | CONSTRUCTION DRAWINGS. | | | | | | HTTP://WWW.FEMA.GOV/LIBRARY/VIEWRECORD.DO?ID=1383 | | | | | | 2. UNITY OF TITLE TO BE RECORDED PRIOR TO PERMIT | | | ISSUANCE, FBC302.1. | | | | | | 3. SEE SOILS REPORT. DESIGN SPECIFIC SOILS EXPLORATION | | | REQUIRED. FBC R 401.4. | | | | | | 4. THE ARCHITECT???S SEAL IS NOT LEGIBLE, AND | | | ARCHITECT???S INFORMATION (LICENSE NUMBER, PRINTED | | | NAME) ARE NOT ON THE PLAN. PLEASE ADDRESS. | | | | | | 5. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB. | | | | | | 6. PROVIDE INFORMATION REGARDING THE FIREPLACE. PROVIDE | | | A DETAIL AND LISTING INFORMATION IF APPLICABLE, FBC106. | | | | | | 7. FBC R 311.4.1, EXIT DOOR WITH A LEAF OF 36IN | | | REQUIRED. SEE ALSO THE FOLLOWING NON BINDING | | | INTERPRETATION. PLEASE FEEL FREE TO CONTACT ME TO | | | DISCUSS. | | | | | | HTTP://WWW.FLORIDABUILDING.ORG/UPLOAD/FBC/CODEID_6758_6 | | | 475.PDF | | | | | | 8. INSULATION ON THE FRAME WALL IS SHOWN AS PERMAFOIL | | | 4.1, PLEASE SEE REQUIREMENTS OF FBC R CHAPTER 11. | | | | | | 9. SPECIFY PLYWOOD FLOOR DIMENSION, FBC R 501.2. | | | | | | 10. PROVIDE INFORMATION REGARDING THE ATTIC STORAGE | | | (SPECIFY LOAD REQUIREMENT) FBC R 301.5. | | | | | | 11. NO VAPOR BARRIER, LATH, BOND BREAK, STUCCO | | | THICKNESS, SHOWN ON WALL DETAIL FBC R. SEE ITEM 8, | | | INCORRECT INSULATION TYPE AND NO PLYWOOD OR FASTENING | | | SPECIFIED. PLEASE REVISE. | | | | | | 12. PROVIDE A DETAIL FOR STAIR AND GUARDRAIL. | | | | | | 13. FOUNDATION PLAN DOES NOT PROVIDE ELEVATION CHANGES. | | | | | | 14. SPECIFY ROOF UPLIFT LOADS, FBC R 301. | | | | | | 15. PRIOR TO RESUBMITTAL, PLEASE CONFIRM THAT PLANS ARE | | | COMPLETE WITH ALL APPLICABLE DETAILS. | | | ENOUGH INFORMATION AND DETAIL IS TO BE PROVIDED TO | | | DETERMINE CODE COMPLIANCE AND TO PERFORM INSPECTIONS. A | | | COMPLETE REVIEW CANNOT BE DONE AT THIS TIME. | | | | | | 16. IMPACT FEES DUE TO PALM BEACH COUNTY, 561-233-5025. | | | PLANS ARE TO BE STAMPED AND RECEIPT PROVIDED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-03-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-03-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-03-17 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-02-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-02-03 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-02-02 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2011-02-03 15:07:50 | PROVIDE AN INTERSYSTEM BONDING STRIP AT THE SERVICE. | | | NEC 250.94 | | | PROVIDE THE INTERRUPTING (AIC) CURRENT RATING FOR THE | | | ELECTRICAL SERVICE. NEC 110.9 | | | NOTE ON THE PLAN THAT THE SMOKE DETECTORS ARE TO BE | | | INTERCONNECTED. FBC R313.2 | | | PROVIDE AN APPLIANCE RECEPTACLE OUTLET AT THE ISLAND | | | COUNTERTOP SPACE. NEC 210.50(C)(2). | | | PROVIDE A SUPPORTING CALCULATION FOR THE REDUCTION IN | | | SIZE OF THE GROUNDED CONDUCTOR (NEUTRAL) NEC 310.15 (A) | | | (6), 215.2 | | | PROVIDE A LIGHTING OUTLET AND A SWITCH FOR THE ATTIC | | | STORAGE AREA. NEC 210.70(3) | | | NOTE ON THE PLANS THE REQUIRED WORKING CLEARANCES FOR | | | THE AC COMPRESSOR DISCONNECTS. NEC 110.26 | | | NOTE THE SERVICE EQUIPMENT AND WIRE WAY MUST BE LISTED | | | FOR OUTDOOR USE. NEC 110.11 | | | LOCATE THE ELECTRIC SERVICE EQUIPMENT AND ELECTRIC | | | PANELS ON THE PLAN. COORDINATE THE LOCATION OF THE AC | | | UNITS, SEE SHEET E-1 AND M- 1. | | | ATTIC | | | | | | ROBERT LECKY, ELECTRIC PLAN REVIEW, 561-805-6718 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2011-03-25 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2011-03-25 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2011-03-25 |
Time |
|
Sent To |
|
|
| Notes |
| 2011-03-25 08:58:20 | PASSED WITH PROVISO | | | | | | IF USING PAVERS, DRIVEWAY AGREEMENT MUST BE SUPPLIED | | | BEFORE C.O. | | | I HAVE ATTACHED ONE TO THE PLANS FOR YOUR INFORMATION. | | | ANY QUESTIONS CONTACT ME AT YOUR CONVENIENCE. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2011-02-14 |
Time |
07:40 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2011-02-14 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2011-02-14 07:58:06 | RESPOND TO ALL COMMENTS IN WRITING: | | | | | | #1 PROVIDE PLAN SHOWING STREET R.O.W. AND REMOVAL OF | | | EXSITING CONCRETE APRONS. | | | YOU ARE ONLY ALLOWED (2) TEN FOOT WIDE APRONS. | | | SEPARATE DRIVEWAY PERMIT IS REQUIRED. THIS WOULD | | | INCLUDE DEMOLITION. | | | | | | #2 PROVIDE SITE CALCULATION AS FOLLOWS: | | | TOTAL PERVIOUS | | | TOTAL IMPERVIOUS | | | TOTAL SITE | | | IN S.F. AND IN AC. | | | | | | #3 MUNICIPAL CODE 94-482 - REQUIRED PARKING MAY BE | | | LOCATED IN A FRONT YARD; HOWEVER, THE LESSER OF 1,000 | | | SQUARE FEET OR 75 PERCENT OF THE FRONT YARD AREA MUST | | | BE LANDSCAPED. | | | PROVIDE CALCULATION BASED ON YOUR SETBACK AREA. | | | | | | #4 FOR NEW APRONS PLEASE USE CITY STANDARD APRONS: | | | HTTP://WWW.CITYOFWPB.COM/ENGINEERING/PDF/STANDARDS/GC-6 | | | .PDF | | | OR | | | HTTP://WWW.CITYOFWPB.COM/ENGINEERING/PDF/STANDARDS/GC-7 | | | .PDF | | | HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_STANDARDS.HTM | | | | | | THANK YOU FOR YOUR ATTENTION. FEEL FREE TO CALL IF ANY | | | QUESTIONS. | | | | | | MANUEL JULIAN GONZALEZ | | | CSD ENGINEERING REVIEW | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-03-30 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-03-24 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-11 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2011-03-11 16:44:47 | SENT TO R19. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-02-14 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-01-27 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2011-01-27 12:27:15 | ****************EXPEDITED**************** | | | R--11 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2011-03-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-21 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-21 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2011-03-21 17:16:25 | MU 2011 4279 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2011-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-03 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-02-03 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2011-02-03 17:29:06 | 233-5025 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-17 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-03-17 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2011-03-17 09:30:13 | MECHANICAL PROVISO | | | | | | 1) THE AIR HANDLERS LOCATED IN THE ATTIC SHALL BE | | | LOCATED WITHIN 6 FEET OF AN ACCESS OPENING AND COMPLY | | | WITH FBC M1305.1.3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-02-04 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-02-04 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2011-02-04 16:16:05 | DENIED BY MECHANICAL | | | | | | 1) ON SHEET M-1 THE WALL AT LAUNDRY ROOM #1 ON THE | | | FIRST FLOOR IS SHOWN IN A DIFFERENT LOCATION THAN ON | | | A-1 OF THE ARCHITECTURAL PLAN. IF THE WALL IS LOCATED | | | AS SHOWN ON A-1 THE RETURN LOCATED IN THE LAUNDRY ROOM | | | WILL VIOLATE CODE SECTION M1602.2(3) OF THE 2007 FBC | | | RESIDENTIAL CODE. PLEASE CORRECT. | | | | | | 2) SHOW COMPLIANCE WITH FBCR M1305.1.3 FOR ACCESS TO | | | THE AIR HANDLER UNITS LOCATED IN THE ATTIC. | | | | | | 3) ON SHEET M-1 THE TRANSFER DUCT FROM THE GUEST | | | BEDROOM IS TOO SMALL. FBCR M1602.4 REQUIRES THE | | | TRANSFER DUCT TO BE 1.5 TIMES THE CROSS SECTIONAL AREA | | | OF THE SUPPLY DUCTS ENTERING THE SPACE IT'S SERVING. | | | PLEASE CORRECT. | | | | | | 4) THE FLOOR PLAN FOR THE MASTER BATH ON SHEET M-2 DOES | | | NOT CORRESPOND WITH THE ONE ON A-2. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-03-17 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-03-17 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-02-04 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-02-04 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2011-02-04 11:54:10 | DENIED BY PLUMBING | | | | | | 1) THE WASHING MACHINE ON THE SECOND FLOOR IS NOT SHOWN | | | ON THE PLUMBING ISOMETRIC DRAWING ON SHEET E-3. PLEASE | | | SHOW ON DRAWINGS. | | | | | | 2) THE TWO WATER CLOSETS IN HIS AND HER BATH ARE NOT | | | VENTED ON THE ISOMETRIC DRAWING. PLEASE CORRECT PER FBC | | | R P3101.2.1. | | | | | | 3) THE WET VENT FOR THE FIRST FLOOR GUEST BATHROOM IS | | | DOWNSTREAM OF THE TWO FIXTURES IT IS VENTING. PLEASE | | | CORRECT PER FBC R P3108.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-03-22 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-03-22 |
Time |
13:29 |
Rev Time |
1.50 |
| Received By |
eschneid |
Date |
2011-03-22 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2011-03-22 12:04:10 | PASSED | | | | | | POOL, FENCES AND GATES REQUIRE SEPARATE PERMITS. | | | | | | PLEASE CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-02-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-02-07 |
Time |
10:32 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2011-02-07 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2011-02-07 12:10:57 | FAILED | | | | | | 1) PROVIDE A COPY OF THE RECORDED UNITY OF TITLE. | | | PLEASE NOTE THAT THE UNITY OF TITLE SHALL BE SUBMITTED | | | TO VINCE NOEL, CITY SURVEYOR, FOR REVIEW AND APPROVAL | | | PRIOR TO RECORDATION. | | | | | | 2) SUBMITTAL OF A LANDSCAPE PERMIT AND AN IRRIGATION | | | PERMIT ARE REQUIRED PRIOR TO ZONING APPROVAL OF THIS | | | PERMIT. | | | | | | 3) THE SURVEY AND THE SITE PLAN SHOW DIFFERENT SITE | | | LAYOUTS. IF THE SURVEY IS TO SHOW THE PROPOSED SITE | | | LAYOUT, THEN IT SHALL SHOW IT ACCURATELY. | | | | | | 4) TWO COPIES OF A SURVEY SHOWING EXISTING CONDITIONS, | | | INCLUDING THE CURRENT DRIVEWAY LOCATIONS, SHALL BE | | | PROVIDED. | | | | | | 5) THE A/C UNITS SHALL BE SHOWN ON THE SITE PLAN. | | | | | | 6) PROVIDE THE DIMENSIONS OF THE PROPOSED DRIVEWAY | | | CONNECTIONS TO FOREST HILL BLVD. PLEASE NOTE THAT | | | NEITHER CONNECTION MAY BE WIDER THAN 10 FEET (PLAN | | | SCALES AT 10 FEET) NOR MAY THERE BE MORE THAN 2 | | | CONNECTIONS. | | | | | | 7) PROVIDE THE MATERIAL OF THE DRIVEWAY. | | | | | | 8) PROVIDE THE FRONT YARD LANDSCAPE CALCULATIONS. THERE | | | SHALL BE AT LEAST 1,000 SQUARE FEET TO LANDSCAPE AREA | | | IN THE FRONT YARD. | | | | | | 9) PER SECTION 94-611 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, THE DEFINITION OF DWELLING | | | UNIT REQUIRES THAT ALL ROOMS BE ACCESSIBLE FROM THE | | | INTERIOR OF THE UNIT. THE MEDIA ROOM, SUMMER KITCHEN | | | AND CABANA BATH ARE NOT ACCESSIBLE FROM THE INTERIOR OF | | | THE HOUSE, BUT RATHER REQUIRE LEAVING THE HOUSE AND | | | CROSSING THE LOGGIA TO ENTER. | | | | | | 10) THE ELEVATIONS ARE MISLABELED AS 1/8" SCALE WHEN | | | THEY ARE ACTUALLY 1/4" SCALE. PLEASE REVISE. | | | | | | 11) PLEASE PROVIDE THE BUILDING HEIGHT AS DEFINED BY | | | THE CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS - BUILDING, HEIGHT OF, MEANS THE VERTICAL | | | DISTANCE FROM THE MEAN GRADE OF A LOT AT THE FRONTAGE | | | OF THE BUILDING TO THE HIGHEST POINT OF THE TOP OF THE | | | STRUCTURE OF A FLAT ROOF, OR TO THE DECK LINE OF A | | | MANSARD ROOF, OR TO THE MID-HEIGHT LEVEL BETWEEN EAVES | | | AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. THE | | | BUILDING HEIGHT DIMENSIONS THAT HAVE BEEN PROVIDED ARE | | | FROM THE FINISHED 1ST FLOOR NOT THE MEAN GRADE AS | | | REQUIRED, NOR DO THEY SHOW THE MID-HEIGHT LEVEL. PLEASE | | | NOTE THAT PER SECTION 94-72 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, THE HEIGHT ALLOWANCE IN THE | | | SINGLE FAMILY 7 ZONING DISTRICT IS 30 FEET. | | | | | | 12) THE TALLER CHIMNEYS EXCEED THE ALLOWED HEIGHT | | | WITHIN THE SINGLE FAMILY 7 ZONING DISTRICT. THE ALLOWED | | | BUILDING HEIGHT OF 30 FEET PLUS THE ADDITIONAL 10% | | | HEIGHT EXCEPTION ALLOWED BY SECTION 94-306 OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS PERMIT A | | | CHIMNEY TO MEASURE 33 FEET TO THE HIGHEST POINT. PLEASE | | | NOTE THAT THIS INCLUDES THE CHIMNEY CAP. THE ELEVATION | | | DRAWINGS DO NOT MEASURE THE HEIGHT OF THE CHIMNEYS | | | CORRECTLY. THE MEAN GRADE (SEE PREVIOUS COMMENT) SHALL | | | BE THE STARTING POINT AND THE CHIMNEY CAP SHALL BE THE | | | ENDING POINT. THE 35'10" DIMENSION, WHILE NOT MEASURED | | | CORRECTLY, EXCEEDS THE DISTRICT HEIGHT ALLOWANCE. | | | | | | 13) PLEASE NOTE THAT THE POOL, SPA, ANY NEW | | | FENCES/WALLS, AND GATES WILL REQUIRE SEPARATE PERMITS. | | | | | | PLEASE CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | |
|
|