Plan Review Details - Permit 11010294
Plan Review Stops For Permit 11010294
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-03-01 Cont ID  
Sent By jgomez Date 2011-03-01 Time 14:55 Rev Time 0.00
Received By jgomez Date 2011-03-01 Time 14:55 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-01-18 Cont ID  
Sent By jgomez Date 2011-01-18 Time 10:27 Rev Time 0.00
Received By jgomez Date 2011-01-18 Time 09:38 Sent To  
Notes
2011-01-18 10:34:23RESIDENTIAL (R3) GARAGE CONVERSION BUILDING REVIEW
 CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- PLANS PROVIDED NEED TO PROVIDE COMPLIANCE WITH THE
 EMERGENCY EGRESS REQUIREMENTS OF SEC. R310.1 OF 2007
 FLORIDA RESIDENTIAL CODE.
  
 2- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 VALUE NEED TO INCLUDE ALL LABOR AND MATERIALS TO BUILD
 THE BEDROOM, THE BATHROOM AND THE CLOSET. SEC. 108.3
 CITY AMENDMENTS TO FBC.
  
 3- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 4- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT
 IF FEES ARE DUE.
  
 5- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 N1100.0 OF CHAPTER 11 OF 2007 FLORIDA RESIDENTIAL CODE.
 ***NOTE: MAKE SURE CORRECT UPDATED FORM IS PROVIDED.
 COMPLETE ALL THE INFORMATION ON THE FORM. AND, MAKE
 SURE ALL SIGNATURES ARE PROVIDED AT THE BOTTOM OF THE
 FORM USED.
  
 6- SPECIFY ON PLANS INSULATION ON EXTERIOR WALLS AND
 CEILING. CHANGING USE FROM GARAGE TO BEDROOM. THEREFORE
 EXISTING WALLS AND CEILING MAY NEED TO ADD THE REQUIRED
 INSULATION.
  
 7- SPECIFY SAFETY GLASS IN SHOWER AREA AS REQUIRED BY
 SEC. R308.4 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 8- SPECIFY TWO LAYERS OF VAPOR BARRIER AS REQUIRED BY
 SEC. R703.6.3 2007 FLORIDA RESIDENTIAL CODE.
  
 9- SPECIFY STUCCO THICKNESS AS REQUIRED BY TABLE
 R702.1(1) 2007 FLORIDA RESIDENTIAL CODE. 5/8" MIN.
 REQUIRED.
  
 10- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) NEW WINDOWS. COORDINATE WITH ITEM #1 ABOVE.
  
 B) SHUTTERS. IF WINDOWS DON'T HAVE IMPACT GLASS. AND
 PROVIDE SHUTTERS COMPLETE INSTALLATION SCHEDULE.
 SPECIFY ON SHUTTERS DRAWINGS SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING TO BE USED.
  
 11- SPECIFY ON PLANS THE VENTILATION AND LIGHT REQUIRED
 FOR THE BATHROOM BY SEC. R303.3 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-01-31 Cont ID  
Sent By rlecky Date 2011-01-31 Time 08:44 Rev Time 0.00
Received By rlecky Date 2011-01-31 Time 08:42 Sent To  
Notes
2011-01-31 08:44:13PROVISO:
 REQUIRES HARD WIRED AND INTERCONNECTED SMOKE DETECTORS
 INSIDE AND OUTSIDE THE BEDROOM. FBC R313.2
  
 ROBERT LECKY, ELECTRIC PLAN REVIEW, 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-02-22 Cont ID  
Sent By jgomez Date 2011-02-22 Time 09:45 Rev Time 0.00
Received By jgomez Date 2011-02-22 Time 09:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-13 Cont ID  
Sent By jwitmer Date 2011-01-13 Time 12:06 Rev Time 0.00
Received By jwitmer Date 2011-01-13 Time 12:03 Sent To  
Notes
2011-01-13 12:06:01INCOMING SENT TO R-7. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-02-22 Cont ID  
Sent By jgomez Date 2011-02-22 Time 09:44 Rev Time 0.00
Received By jgomez Date 2011-02-22 Time 09:44 Sent To  
Notes
2011-02-22 09:45:24NO FEES DUE. IMPACT FEE PLAN REVIEW MU2011-2839.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-01-18 Cont ID  
Sent By jgomez Date 2011-01-18 Time 09:34 Rev Time 0.00
Received By jgomez Date 2011-01-18 Time 09:34 Sent To  
Notes
2011-01-18 09:38:06BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-03-01 Cont ID  
Sent By jgomez Date 2011-03-01 Time 14:54 Rev Time 0.00
Received By jgomez Date 2011-03-01 Time 14:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-01-18 Cont ID  
Sent By jgomez Date 2011-01-18 Time 09:31 Rev Time 0.00
Received By jgomez Date 2011-01-18 Time 09:10 Sent To  
Notes
2011-01-18 09:34:29RESIDENTIAL (R3) PLUMBING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- LICENSED PLUMBER TO PROVIDE SANITARY ISOMETRIC RISER
 DIAGRAM AS REQUIRED BY SEC. 106.3.5.4(9) OF CITY
 AMENDMENTS TO FBC.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status P Date 2011-01-27 Cont ID  
Sent By astelly Date 2011-01-27 Time 18:21 Rev Time 0.00
Received By astelly Date 2011-01-27 Time 18:21 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved