| 2011-02-22 09:41:33 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | |
| | 1. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R |
| | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS |
| | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE |
| | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM |
| | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF). |
| | |
| | REVISE THE INSTALLATION SCHEDULE SUBMITTED AS FOLLOWS: |
| | |
| | A. NOT CLEAR HOW WIND DESIGN PRESSURES HAVE BEEN |
| | DETERMINED, PLEASE CLARIFY. |
| | B. SHUTTER MOUNTING CONNECTION TYPE IS TO SPECIFY |
| | SPECIFIC DETAIL FOR MOUNTING, SEE SHEET 2. |
| | C. NOT CLEAR HOW 7" SHUTTER GLASS SEPARATION WILL BE |
| | ACCOMPLISHED. |
| | D. NOT CLEAR HOW SPAN HAS BEEN DETERMINED. |
| | E. NOT CLEAR HOW EDGE DISTANCE HAS BEEN DETERMINED. |
| | F. ANCHOR SPACING TO COMPLY WITH PRODUCT APPROVAL, |
| | INCOMPLETE (EITHER BLANK OR N/A) OR DOES NOT COMPLY |
| | WITH CHART ON SHEET 3 OF PRODUCT APPROVAL. |
| | |
| | 2-3. ADDRESSED. |
| | |
| | 4. PROVIDE A STRUCTURAL DETAIL FOR THE WALL FRAMING TO |
| | SHOW HOW THIS PROPOSED IMPROVEMENT WILL RESIST WIND |
| | LOADS, FBC R 301. STATE WIND DESIGN CRITERIA ON THE |
| | PLAN (140 MPH EXPOSURE C). DESIGN IS TO BE IN |
| | ACCORDANCE WITH THE METHODS LISTED IN FBC R 301.1 AND A |
| | DESIGNER LICENSED FOR THIS SCOPE OF WORK IS TO SIGN THE |
| | PLAN, FS 471, 481, 489. |
| | |
| | NOT ADDRESSED. PLEASE ADDRESS COMMENTS AND HAVE A |
| | DESIGNER LICENSED TO DESIGN THIS SCOPE OF WORK TO SIGN |
| | AND SEAL THE PLAN. PLANS TO BE ARCHITECTURAL QUALITY, |
| | TO SCALE, MINIMUM 1/8". |
| | |
| | 5. REVISE APPLICATION TO REFLECT CORRECT VALUE (VALUE |
| | OF MATERIAL AND LABOR) AND CORRECT SCOPE OF WORK |
| | (ENCLOSE PORCH). |
| | |
| | NOT ADDRESSED. PROVIDE A VALUE WHICH INCLUDES VALUE OF |
| | MATERIALS AND LABOR. |
| | |
| | 6. DUE TO INSUFFICIENT INFORMATION PROVIDED FOR REVIEW, |
| | PLEASE BE AWARE THAT IT IS POSSIBLE THAT THE REVISED |
| | PLAN MAY HAVE COMMENTS. |