Plan Review Details - Permit 11010070
| Plan Review Stops For Permit 11010070 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-01-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-01-19 |
Time |
07:56 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-01-19 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2011-01-11 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-01-11 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-01-11 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-01-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-01-20 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-01-20 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-02-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-02-02 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-02-02 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2011-02-02 11:57:45 | UNDER 5 K PLUMBING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-01-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-01-26 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-01-10 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-02-04 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-02-04 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-02-04 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2011-02-04 10:37:12 | MED GAS PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-01-13 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-01-13 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-01-13 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2011-01-13 10:01:20 | FBC PLUMBING 2007 | | | NFPA 99C 2002 | | | REVISION REVIEW #1 | | | DENIED: | | | | | | 1. PLEASE SUBMIT VACUUM PUMP MANUFACTURERS | | | SPECIFICATIONS SHOWING THAT 3/4" MAIN AND 1/2" RISERS | | | ARE SUGGESTED OR REQUIRED. RAMVAC VACUUM PUMPS REQUIRE | | | 2" MAINS BELOW FLOOR SLOPED AT 1/4" PER FOOT. VACSTAR'S | | | SMALLEST PUMP VS 20 REQUIRES A MINIMUM OF 1" MAIN - | | | ETC. | | | | | | 2. SANITARY DRAWINGS APPEAR TO BE ELIMINATING THE | | | DRAINS FOR THE CHAIRS IN TREATMENT ROOMS 1 & 3. ARE | | | THESE CHAIRS EXISTING? | | | | | | 3. NFPA 99C 2002 5.3.3.6.3 VACUUM DRAINS ARE TO BE | | | DIRECTLY CONNECTED TO THE SANITARY, TRAPPED, AND | | | VENTED. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy