| Plan Review Stops For Permit 10120637 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-02-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-10 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-02-10 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2011-02-10 17:39:16 | ***PROVISO*** | | | ***REVISION REQUIRED*** | | | | | | THE CENTER PANEL OF THE ARCHED FIXED WINDOW, FAMILY | | | ROOM, EXCEEDS THE PRODUCT APPROVAL LIMITATION. EITHER | | | SUBMIT NEW PRODUCT APPROVAL, REVISE THE WINDOW PANEL | | | SIZE, OR SUBMIT SITE SPECIFIC ENGINEERING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-04 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-04 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2011-01-04 16:58:58 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SITE PLAN AND MECHANICAL PLAN SHOW THE MECHANICAL | | | EQUIPMENT AND SLAB ENCROACHING THE PROPERTY LINE. OTHER | | | SHEETS SHOW THE MECHANICAL EQUIPMENT IN ANOTHER | | | LOCATION. PLEASE CORRELATE. | | | | | | 2. PROVIDE OVERALL AND UNIT SIZE FOR THE ARCHED FIXED | | | WINDOW, FAMILY ROOM. THE HEIGHT IS PROVIDED, NO WIDTH | | | SHOWN FOR EITHER THE OVERALL OPENING OR FOR THE UNITS | | | SEPARATED BY MULLIONS. FBC301. | | | | | | 3. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR | | | THE ANCHORS SPECIFIED FOR THE MECHANICAL UNITS, | | | FAC9B72. WIND RESISTANCE TO SLIDING AND OVERTURNING TO | | | BE SHOWN AS WELL AS UPLIFT. | | | | | | 4. 1" AND 2" MULLION PRODUCT APPROVALS WERE SUBMITTED. | | | PLEASE SPECIFY PROPOSED LOCATIONS. | | | | | | 5. SEE FBC R 1104.A.2, WALLS CONSIDERED CEILINGS. | | | COFFERED CEILINGS NOT SHOWN ON CEILING SQUARE FOOT AREA | | | ON ENERGY CALCS. | | | | | | 7. ENERGY CALC SHOWS TWO DIFFERENT TYPES OF FRAME WOOD | | | ADJACENT WALLS (R11 AND R4.1), PLEASE SPECIFY ON PLAN. | | | | | | 8. PLEASE CHECK ALL ENERGY CALC ITEMS FOR CONSISTENCY | | | WITH THE PLAN SUBMITTED. FOR INSTANCE, ROOF ON ENERGY | | | CALC IS SHINGLE, PLAN SHOWS TILE. GARAGE CEILING HEIGHT | | | ON PLAN IS 10', ENERGY CALC SHOWS 8'. ENERGY CALC SHOWS | | | TWO EXTERIOR DOORS, EAST ORIENTATION. PLAN SHOWS ONE | | | DOOR, WEST ORIENTATION. | | | | | | 9. SEE PREVIOUS COMMENT, AND ALSO NOTE THAT GARAGE | | | FRAME WALL FACES WEST, ENERGY CALC SHOWS EAST | | | ORIENTATION. PLEASE NOTE THAT ALTHOUGH THE SITE PLAN | | | SHOWS "NORTH" ORIENTED TOWARDS THE TOP OF THE PAGE, | | | ARCHITECTURAL SHEETS ARE REVERSED. NO "NORTH" | | | DESIGNATION PROVIDED ON A SHEETS, BUT BASED ON THE SITE | | | PLAN, "NORTH" WOULD BE THE BOTTOM OF THE PLAN. PLEASE | | | CONFIRM ORIENTATION OF ALL ITEMS AND REVISE AS | | | NECESSARY. | | | | | | | | | | | | PLAN SHOWS GARAGE FRAME WALL FACING WEST, ENERGY CALC | | | SHOWS EAST. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-02-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-02-07 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-02-07 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-01-05 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-01-05 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-01-05 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2011-01-05 15:01:37 | PROVIDE A BONDING BAR AT THE SERVICE. NEC 250-94 | | | NOTE ON THE PLAN THE REQUIREMENT FOR TAMPER RESISTANT | | | RECEPTACLES. NEC 406.11 | | | THE SMOKE DETECTORS MUST BE INTERCONNECTED. FBC R313.2 | | | GFCI PROTECTED RECEPTACLE REQUIRED AT THE MECHANICAL | | | EQUIPMENT. NEC 210.63 | | | | | | ROBERT LECKY, ELECTRICAL PLANS REVIEW, 561-805-6718 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2011-02-23 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-02-23 |
Time |
16:23 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2011-02-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2011-02-23 09:40:04 | PASSED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2011-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-24 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-24 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2011-01-24 13:56:06 | PASSED UNDER 10120639 | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
P |
Date |
2011-02-23 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2011-02-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2011-02-23 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2011-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-02-08 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-02-08 |
Time |
07:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2011-01-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-07 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2011-01-07 10:50:12 | GAS REVIEW IS DENIED | | | | | | 1) SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EDH NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE AND SECTION OF PIPE. | | | | | | 2) INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2007 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | THE REQUIREMENTS FOR GAS PERMITS CAN BE FOUND AT THIS | | | LINK. HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/GAS%20P | | | ERMIT%20APPLICATION%20REQUIREMENTS.PDF | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-02-24 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-02-07 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2011-02-07 08:06:11 | R8 "EXPEDITED" 2ND RUN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-24 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-28 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2010-12-28 15:50:23 | R--12 | | | ****************EXPEDITED****************** |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2011-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-04 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-04 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2011-01-04 11:40:09 | RECEIPT # MU-2010-017829-0000 | | | 4168 SF | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
N |
Date |
2011-02-17 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2011-02-17 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2011-02-17 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2011-02-17 09:30:17 | ***LANDSCAPE REVIEW NOT REQUIRED*** | | | | | | PLEASE REFER TO PERMIT # 10120635 FOR THE LANDSCAPE | | | PERMIT AND PLANS.--RAK |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-30 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-12-30 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-12-30 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2010-12-30 16:30:53 | ***LANDSCAPE REVIEW NOT REQUIRED*** | | | | | | PLEASE REFER TO PERMIT #10120635 FOR LANDSCAPE PERMIT | | | AND PLANS---RAK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-02-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-11 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-02-11 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2011-02-11 16:14:51 | OK PER HM | | | | | | PROVISO - PROVIDE LEGIBLE ENGINEERING FOR A/C TIE DOWN | | | AT INSPECTION | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-01-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-01-04 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-01-04 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2011-01-04 11:28:14 | ****CORRECTIONS**** | | | HAROLD MOSER, MECHANICAL PLANS EXAMINER | | | 561-805-6732 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. FS489.105, FS471, THE INDIVIDUAL RESPONSIBLE FOR THE | | | MECHANICAL DESIGN (DONALD O'BRYON) IS NOT THE PERSON | | | LISTED ON THE DBPR WEBSITE FOR THE LICENSE NUMBER ON | | | THE PLAN, CAC032382. PLEASE ADDRESS. | | | | | | 2. THE SITE PLAN S1 AND MECHANICAL PLAN SUBMITTED SHOW | | | THE EQUIPMENT ENCROACHING THE PROPERTY LINE (OUTISDE OF | | | THE GARAGE). THE SITE PLAN PREPARED BY THE SURVEYOR AND | | | ARCHITECTURAL SHEETS SHOW THE MECHANICAL EQUIPMENT | | | OUTSIDE THE KITCHEN. PLEASE ADDRESS. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-02-08 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-02-08 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-01-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-07 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-07 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-02-17 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-02-16 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2011-02-15 |
Time |
10:52 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-01-13 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-01-13 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2011-01-11 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2011-01-11 17:02:58 | PLANNING AND ZONING: *** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | | | | 2. PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED | | | OFF-STREET PARKING SPACES FOR LESS THAN FOUR | | | RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE | | | PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED | | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | | YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN | | | THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH, | | | NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION | | | 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO | | | PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE. | | | | | | PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE | | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | | BUILDING FACADE). | | | SHOW ALL INFORMATION ON THE SURVEY AND PLANS. | | | | | | 3. THE SETBACKS WITHIN THIS PROPERTY SHALL BE A MINIMUM | | | OF THE FOLLOWING: | | | | | | 3'-1" ONE SIDE AND 4'-11" THE OTHER SIDE. A MINIMUM OF | | | 8' SHALL BE MAINTAINED BETWEEN HOUSES. THE APPLICANT | | | SHALL PROVIDE THE LOCATION AND DIMENSION OF THE HOME(S) | | | ADJACENT TO THE SUBJECT PROPERTY. SHOW DIMENSIONS IN | | | FEET AND INCHES (I.E. 3'-6"). SINCE PROPERTY IS | | | SOMEWHAT ANGLED, SHOW DIMENSIONS WITHIN THE FRONT, MID | | | AND REAR OF THE LOT AREAS THAT COMPLY WITH THE SETBACK | | | REQUIREMENTS ABOVE. THIS COMMENT IS FOR THE SURVEY. THE | | | SITE PLAN SHOWS THE CORRECT DIMENSIONS. | | | | | | 4, INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO SECTION | | | 94-305(B)(4) OF THE ZLDR: MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | THERE ARE DISCREPANCIES BETWEEN THE SURVEY AND THE SITE | | | PLAN. THE PLANS SHOW THE EQUIPMENT ENCROACHING INTO THE | | | ADJACENT PROPERTY AND IN A DIFFERENT LOCATION THAN THE | | | SURVEY. | | | | | | 5. REVISE DISCREPANCIES FOR THE LOCATION OF THE HOME | | | REGARDING THE FRONT SETBACK. THE SITE PLAN SHOWS THE | | | BUILDING'S GARAGE AT 20'11" AND THE SURVEY SHOWS THE | | | BUILDING'S FRONTAGE AT 24.3'. THE DIMENSION OF THE | | | STRUCTURE SHALL BE FROM THE CLOSEST STRUCTURE INCLUDING | | | THE ARCHITECTURAL FEATURES BY THE GARAGE'S SIDE FACADE | | | AS SHOWN ON THE SITE PLAN. | | | | | | 6. PROVIDE THE TOTAL HEIGHT OF THE BUILDING'S HEIGHT ON | | | SHEET A05. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|