Plan Review Details - Permit 10120502
| Plan Review Stops For Permit 10120502 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-14 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-14 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2011-03-14 09:54:24 | PROVISO - NO DOORS INCLUDED IN SCOPE | | | (ASSEMBLY OCCUPANCY PER CONTRACTOR, SOUP KITCHEN) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2011-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-02-15 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-02-15 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2011-02-15 09:50:00 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS REVIEWS: | | | | | | 1. REVISE PLAN TO SHOW TYPE OF OPENING (DOOR OR | | | WINDOW), FBC1003.6. IF YOU PROPOSE TO COVER REQUIRED | | | EXIT DOORS WITH SHUTTERS, PROVIDE A LIFE SAFETY PLAN | | | WHICH SHOWS THE FOLLOWING INFORMATION: | | | | | | OVERALL BUILDING DIMENSIONS | | | OCCUPANCY CLASSIFICATION FBC CHAPTER 3 | | | EXITING INFORMATION | | | | | | 3RD REVIEW, PLEASE PROVIDE REQUESTED INFORMATION. | | | OCCUPANCY CLASSIFICATION NOT PROVIDED, OVERALL | | | DIMENSIONS NOT PROVIDED, THEREFORE OCCUPANT LOAD CANNOT | | | BE DETERMINED. PLAN PROVIDED SHOWS TWO DOORS, ONE | | | OUTSWING DOOR COVERED BY PANELS, NO OTHER INFORMATION. | | | THIS DOES NOT APPEAR TO COMPLY WITH THE REQUIREMENTS OF | | | FBC CHAPTER 10. EITHER REVISE PLAN TO SHOW COMPLIANCE | | | WITH FBC CHAPTER 10 (MEANS OF EGRESS) OR REMOVE DOOR | | | FROM SCOPE OF WORK. | | | | | | 2. ADDRESSED. | | | | | | 3. PLEASE SEE INSTALLATION SCHEDULE SUBMITTED, OPENING | | | 4 AND SHEET 4 OF THE PRODUCT APPROVAL. SPACING PROPOSED | | | DOES NOT COMPLY FOR THIS PANEL SPAN. PLEASE REVISE AND | | | CHECK ALL. | | | | | | 4. ADDRESSED. | | | | | | | | | | | | FBC 1003.6, MEANS OF EGRESS CONTINUITY. THE PATH OF | | | EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE | | | INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS | | | OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER. | | | OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH | | | OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY | | | THIS CHAPTER. | | | | | | 1008.1.3.5 SECURITY GRILLS. IN GROUPS B, F, M, R AND S, | | | HORIZONTAL SLIDING OR VERTICAL SECURITY GRILLES ARE | | | PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM | | | THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL | | | KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS | | | OCCUPIED. THE GRILLES SHALL REMAIN SECURED IN THE | | | FULL-OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY | | | THE GENERAL PUBLIC. WHERE TWO OR MORE MEANS OF EGRESS | | | ARE REQUIRED, NOT MORE THAN ONE-HALF OF THE EXITS OR | | | EXIT ACCESS DOORWAYS SHALL BE EQUIPPED WITH HORIZONTAL | | | SLIDING OR VERTICAL SECURITY GRILLES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-01-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-31 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-31 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2011-01-31 09:14:49 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. REVISE PLAN TO SHOW TYPE OF OPENING (DOOR OR | | | WINDOW), FBC1003.6. IF YOU PROPOSE TO COVER REQUIRED | | | EXIT DOORS WITH SHUTTERS, PROVIDE A LIFE SAFETY PLAN | | | WHICH SHOWS THE FOLLOWING INFORMATION: | | | | | | OVERALL BUILDING DIMENSIONS | | | OCCUPANCY CLASSIFICATION FBC CHAPTER 3 | | | EXITING INFORMATION | | | | | | 2. ADDRESSED. | | | | | | 3. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 4. ADDRESSED. | | | | | | | | | | | | FBC 1003.6, MEANS OF EGRESS CONTINUITY. THE PATH OF | | | EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE | | | INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS | | | OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER. | | | OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH | | | OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY | | | THIS CHAPTER. | | | | | | 1008.1.3.5 SECURITY GRILLS. IN GROUPS B, F, M, R AND S, | | | HORIZONTAL SLIDING OR VERTICAL SECURITY GRILLES ARE | | | PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM | | | THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL | | | KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS | | | OCCUPIED. THE GRILLES SHALL REMAIN SECURED IN THE | | | FULL-OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY | | | THE GENERAL PUBLIC. WHERE TWO OR MORE MEANS OF EGRESS | | | ARE REQUIRED, NOT MORE THAN ONE-HALF OF THE EXITS OR | | | EXIT ACCESS DOORWAYS SHALL BE EQUIPPED WITH HORIZONTAL | | | SLIDING OR VERTICAL SECURITY GRILLES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-22 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-22 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2010-12-22 18:04:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. REVISE PLAN TO SHOW TYPE OF OPENING (DOOR OR | | | WINDOW), FBC1003.6. IF YOU PROPOSE TO COVER REQUIRED | | | EXIT DOORS WITH SHUTTERS, PROVIDE A LIFE SAFETY PLAN | | | WHICH SHOWS THE FOLLOWING INFORMATION: | | | | | | OVERALL BUILDING DIMENSIONS | | | OCCUPANCY CLASSIFICATION FBC CHAPTER 3 | | | EXITING INFORMATION | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQURIED, | | | FAC9B72. THE PRODUCT APPROVALS SUBMITTED ARE EXPIRED. | | | | | | 3. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 4. WHEN RESUBMITTING, PLEASE SUBMIT TWO COMPLETE SETS | | | OF PERMIT DOCUMENTS. | | | | | | | | | | | | FBC 1003.6, MEANS OF EGRESS CONTINUITY. THE PATH OF | | | EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE | | | INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS | | | OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER. | | | OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH | | | OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY | | | THIS CHAPTER. | | | | | | 1008.1.3.5 SECURITY GRILLS. IN GROUPS B, F, M, R AND S, | | | HORIZONTAL SLIDING OR VERTICAL SECURITY GRILLES ARE | | | PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM | | | THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL | | | KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS | | | OCCUPIED. THE GRILLES SHALL REMAIN SECURED IN THE | | | FULL-OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY | | | THE GENERAL PUBLIC. WHERE TWO OR MORE MEANS OF EGRESS | | | ARE REQUIRED, NOT MORE THAN ONE-HALF OF THE EXITS OR | | | EXIT ACCESS DOORWAYS SHALL BE EQUIPPED WITH HORIZONTAL | | | SLIDING OR VERTICAL SECURITY GRILLES. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-03-14 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-03-14 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2011-03-07 14:29:45 | SENT TO S. HILL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-02-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-02-08 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-02-08 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2011-02-08 11:51:07 | REVISIONS TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-01-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-01-19 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-01-19 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2011-01-19 10:26:33 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-22 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-22 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
|