| Plan Review Stops For Permit 10120485 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-05-06 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-05-06 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-27 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-27 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2011-04-27 12:31:24 | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | SINGLE HUNG WINDOW AS REQUIRED BY DCA RULE 9B-72. | | | | | | 2) SUBMIT PRODUCT APPROVALS FOR THE STORM PANELS, IF | | | THE NEW WINDOW IS NOT IMPACT RESISTANT. | | | | | | 3) PLEASE CLARIFY WHETHER OR NOT THE DOUBLE OUTSWING | | | ENTRY DOOR AND SIDELITES ARE BEING REPLACED. IF IT IS | | | BEING REPLACED, SUBMIT PRODUCT APPROVALS FOR IT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-10 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-10 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2011-01-10 10:18:02 | DENIED BY BUILDING | | | 2007 FBC W/2009 REVISIONS | | | | | | 1) AN IMPACT FEE PLAN REVIEW BY PALM BEACH COUNTY WILL | | | BE REQUIRED. THE PLANS WILL BE STAMPED BY THE COUNTY. | | | IF ANY FEES ARE DUE A COPY OF THE PAID RECEIPT ALONG | | | WITH THE STAMPED PLANS SHALL BE SUBMITTED TO THE CITY | | | OF WEST PALM CONSTRUCTION SERVICES DEPARTMENT. | | | | | | 2) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C AND | | | THE PLANS SPECIFY CATEGORY B. PLEASE REVISE AND | | | INCREASE THE COMPONENT AND CLADDING PRESSURES | | | ACCORDINGLY. SEE 2007 FBC RESIDENTIAL WITH 2009 | | | REVISIONS SECTION R301.2.1.4.3. | | | | | | 3) THE WALL SECTION ON SHEET 2 DOES NOT SHOW THE | | | FOUNDATION WEEP SCREED. ASTM C 1063 SECTION 7.11.5 | | | REQUIRES A FOUNDATION WEEP SCREED AT THE BOTTOM OF ALL | | | STUCCO COVERED FRAMED EXTERIOR WALLS BELOW THE FLOOR | | | LINE. FBC R703.6 | | | | | | 4) SUBMIT PRODUCT APPROVALS FOR THE NEW SINGLE HUNG | | | WINDOW IN THE FAMILY ROOM. DCA RULE 9B-72. | | | | | | 5) SUBMIT PRODUCT APPROVALS FOR THE HURRICANE PANELS | | | FOR THE NEW WINDOW (UNLESS IT IS A LARGE MISSILE IMPACT | | | WINDOW). DCA RULE 9B-72. | | | | | | 6) THE VALUE OF THE WORK APPEARS TO BE TOO LOW. THE | | | VALUE IS TO INCLUDE THE COSTS OF ALL LABOR, MATERIALS, | | | DESIGN COSTS, OVERHEAD AND PROFIT AS WOULD BE CHARGED | | | BY A CONTRACTOR. PLEASE PROVIDE A COST BREAK DOWN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-27 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-27 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-10 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-10 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2011-01-10 10:53:35 | DENIED BY ELECTRIC | | | 2008 NEC AND 2007 FBC W/2009 REVISIONS | | | | | | 1) UPDATE THE ELECTRICAL DESIGN CRITERIA ON SHEET 2 TO | | | REFERENCE THE 2007 FBC W/2009 REVISIONS AND THE 2008 | | | NEC. | | | | | | 2) THE CODE SECTION FOR SMOKE ALARMS IN THE 2007 FBC | | | RESIDENTIAL IS R313.2.1. PLEASE UPDATE THE CODE | | | REFERENCE ON SHEET 2. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-05-06 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-05-02 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2011-05-02 17:41:35 | TO RM DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-28 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-21 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2011-04-21 14:08:59 | GAVE TO ROBBIE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-10 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-10 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2011-01-10 10:55:03 | NEEDS PBC IMPACT FEE REVIEW. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-04-27 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-04-27 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2011-04-27 10:58:36 | MU-2011-003738-0000 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-04-28 |
Time |
09:11 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2011-04-28 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2011-04-28 09:11:24 | RESTAMP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-12-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-12-28 |
Time |
09:31 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2010-12-28 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2010-12-29 12:02:31 | NO EXPANSION OF FOOTPRINT. LESS THAN 50% VALUE OF | | | STRUCTURE. |
|
|