Plan Review Details - Permit 10120482
Plan Review Stops For Permit 10120482
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-05-10 Cont ID  
Sent By jwitmer Date 2011-05-10 Time 13:28 Rev Time 0.77
Received By jwitmer Date 2011-05-10 Time 13:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-04-14 Cont ID  
Sent By jwitmer Date 2011-04-14 Time 11:12 Rev Time 0.55
Received By jwitmer Date 2011-04-14 Time 11:12 Sent To  
Notes
2011-04-14 11:27:21BUILDING PLAN REVIEW
 PERMIT: 10120482
 ADD: 7620 S DIXIE HWY
 CONT: STRIKE CONSULTING INC.
 TEL: (561)644-1887
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 ACTION: DENIED
  
 1-2) COMPLIED.
  
 3) THE PLANS INDICATE THE INSTALATION OF NEW STORE
 FRONT SYSTEM, AND STEMWALL CONSTRUCTION:
 3A-C) COMPLIED
  
 3D) 2ND REQUEST, RESPONCE COMMENTS INDICATE THE PRODUCT
 APPROVALS THAT WERE TO BE SUBMITTED ARE TO BE LARGE
 MISSILE IMPACT. THE STOREFRONT DOOR AND AND STOREFRONT
 SYSTEM SUBMITTED (NOA 06-0818.02/ NOA 08-1024.07) BOTH
 ARE NON-IMPACT GLAZING.
  
 THE SECOND ISSUE WITH THE STOREFRONT SYSTEM CHART# 2
 THE DESIGN LOAD CAPACITY OF THE GLASS SIZE EXCEEDS THE
 TABLES.
  
 THE THIRD ISSUE IS THE MULLION CAPACITY HAS BEEN
 EXCEEDED FOR BOTH SPACING AND HEIGHT VERSES THE PLANS
 INDICATING THE FRONT STOREFRONT WINDOW UNITS TO BE 6
 FEET WIDE.
  
 THE FOURTH ISSUE WITH THE SUBMITTED PRODUCT APPROVALS,
 ONLY ONE SET OF APPROVALS WERE SUBMITTED FOR NOA
 09-23.09 & 11-0128.03.
 NOTE ON THE ORIGINAL REVIEW ONE SET OF NON-IMPACT
 PRODUCT APPROVALS WERE SUBMITTED FOR STOREFRONT GLAZING
 AND DOOR WITH TRANSOM NON-IMPACT, WITH THE FIRST
 RE-SUBMITTAL THE 2ND SET WERE SUBMITTED, NON-IMPACT
 GLAZING ALSO.
  
 FROM 1ST REVIEW, SHEET A100 ALSO INDICATE THE REUSE OF
 EXISTING SHUTTERS, THE CITY RECORDS DOESN'T INDICATE
 ANY PERMIT WAS EVER PULLED FOR THE INSTALLATION OF
 THESE SHUTTERS NOR CAN THE TESTING FOR LARGE MISSILE
 IMPACT TESTING. 1609.1.4 PROTECTION OF OPENINGS IN
 WIND-BORNE DEBRIS REGIONS, EXTERIOR GLAZING THAT
 RECEIVES POSITIVE PRESSURE IN THE LOWER 60 FEET (18.3
 M) IN BUILDINGS SHALL BE ASSUMED TO BE OPENINGS AND THE
 BALANCE OF GLAZED OPENINGS IN THE REST OF THE BUILDING
 SHALL BE ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT
 RECEIVES POSITIVE PRESSURE IS IMPACT RESISTANT OR
 PROTECTED WITH AN IMPACT RESISTANT COVERING MEETING THE
 REQUIREMENTS OF SSTD 12, ASTM E 1886 AND ASTM E 1996,
 OR MIAMI-DADE TAS 201, 202 AND 203 REFERENCED THEREIN
 AS FOLLOWS: 1. GLAZED OPENINGS LOCATED WITHIN 30 FEET
 (9.1 M) OF GRADE SHALL MEET THE REQUIREMENTS OF THE
 LARGE MISSILE .
  
 4-5) COMPLIED.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-01-05 Cont ID  
Sent By jwitmer Date 2011-01-05 Time 11:59 Rev Time 1.25
Received By jwitmer Date 2011-01-05 Time 10:45 Sent To  
Notes
2011-01-05 12:09:48BUILDING PLAN REVIEW
 PERMIT: 10120482
 ADD: 7620 S DIXIE HWY
 CONT: STRIKE CONSULTING INC.
 TEL: (561)644-1887
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS ARE INDICATED TO BE DESIGNED BY A FLORIDA
 REGISTERED ARCHITECT BUT THERE IS ALSO A YANG DESIGN
 GROUP, INC ON THE TITLE BLOCK WITH NO FLORIDA LICENSE
 NUMBER PLEASE REVIEW FL S S 481. 223 LICENSURE
 REQUIREMENTS FOR INTERIOR DESIGN.
  
 2) THE NEW STORE CONFIGURATION INDICATED ON SHEET A100
 INDICATES A SINGLE EXIT DESIGN FOR THE WHOLE BUILDING,
 PLEASE PROVIDE A LIFE SAFETY PLAN FOR EGRESS TRAVEL
 FROM THE MOST REMOTE POINT IN THE BUILDING, INCLUDE ANY
 KIOSK, STANDS THAT WILL IMPEDE EGRESS. THE
 SINGLE EXIT IS LIMITED IN MERCANTILE OCCUPANCY TO 30
 OCCUPANTS AND TRAVEL DISTANCE OF 75'-0". PLEASE PROVIDE
 THE OCCUPANT LOAD FOR THE TOTAL MERCANTILE SQ FOOTAGE,
 I BELIEVE YOU WILL SEE IT EXCEEDS 30 WHEN USING 30 SQ
 FT / OCCUPANT. SEE FBC-B TABLE 1019.2 &
 TABLE 1004.1.1 REQUIRING A MINIMUM OF TWO EXITS. PLEASE
 NOTE ALSO EGRESS DOORS ARE TO BE SIDE SWING DOORS, TTHE
 OVERHEAD DOORS WILL NOT MEET THE EXCEPTIONS FOR THIS
 OCCUPANCY CLASSIFICATION AND LOAD.
  
 3) THE PLANS INDICATE THE INSTALATION OF NEW STORE
 FRONT SYSTEM, AND STEMWALL CONSTRUCTION:
 3A) PLANS ARE DEFICIENT IN PROVIDING WIND DESIGN
 CRITERIA:1609.6.2 WIND DESIGN PROCEDURES
 1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME
 FROM ANY HORIZONTAL DIRECTION.
 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION1609.5.
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4. NOTE "C" EXPOSURE
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4)
 5) POSITIVE & NEGATIVE DESIGN PRESSURES FOR INTERIOR
 ZONES(4) AND END ZONES(5).
  
 3B) PLANS A100 ALSO INDICATE A NEW KNEE WALL, PLEASE
 PROVIDE DESIGN FOR PART OF THE MWFRS, INCLUDING STEEL
 IMBEDMENT, SIZE OF REBAR & SPACING. ALSO PROVIDE THE
 MINIMUM DESIGN MIX FOR CONCRETE OR GROUT MIX.
  
 3C) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 3D) SHEET A100 ALSO INDICATE THE REUSE OF EXISTING
 SHUTTERS, THE CITY RECORDS DOESN'T INDICATE ANY PERMIT
 WAS EVER PULLED FOR THE INSTALLATION OF THESE SHUTTERS
 NOR CAN THE TESTING FOR LARGE MISSILE IMPACT TESTING.
 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE
 PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS
 SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF
 GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE
 ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES
 POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH
 AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS
 OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE
 TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1.
 GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE
 SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE .
  
 4) SHEET A100 INDICATES A NEW DOOR OPENING CUT INTO A
 BLOCK WALL BUT NO INFORMATION IS PROVIDED ON COLUMNS
 AND EITHER BEAM OR LINTEL TO HOLD THE REMAINDER OF
 BLOCK WORK IN PLACE.
  
 5) SHEET A100 WITHIN THE NEWLY A/C SPACE THE PLANS
 INDICATE A NEWLY TILE FLOOR PLEASE PROVIDE DETAIL FOR
 THE NEW CHANGE IN ELEVATION FROM THE REMAINDER OF THE
 FLOOR. FBC-B 11-4.3.8.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-03-29 Cont ID  
Sent By rlecky Date 2011-03-29 Time 14:35 Rev Time 1.50
Received By rlecky Date 2011-03-29 Time 14:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-01-03 Cont ID  
Sent By rlecky Date 2011-01-03 Time 15:33 Rev Time 0.00
Received By rlecky Date 2011-01-03 Time 15:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-04-01 Cont ID  
Sent By wjolin Date 2011-04-01 Time 15:54 Rev Time 0.00
Received By wjolin Date 2011-04-01 Time 14:22 Sent To  
Notes
2011-04-01 15:37:217620 SOUTH DIXIE HIGHWAY
 PERMIT #10120482
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 TRAVEL DISTANCE TO PORTABLE FIRE EXTINGUISHER EXCEEDS
 75 FEET FROM NORTH STORAGE ROOM.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-12-29 Cont ID  
Sent By mcarsill Date 2010-12-29 Time 13:13 Rev Time 0.00
Received By mcarsill Date 2010-12-29 Time 13:06 Sent To  
Notes
2010-12-29 13:13:327620 SOUTH DIXIE HIGHWAY
 PERMIT NUMBER 10120482
 "REPLACE STOREFRONT, INSTALL HVAC UNIT, FIX BATHROOMS,
 MAKE ADA, INSTALL DOORS
  
  
 1) ADDITIONAL EXIT SIGNS ARE NEEDED; ONE NEAR THE
 DOUBLE DOORS LEADING FROM THE EXISTING RETAIL TO THE
 EXISTING ENVELOPE, AND FROM THE DRAWING TO DIRECT
 PERSONS FROM THE STORAGE AREA AS IT APPEARS THAT NO
 SEPARATION EXISTS.
  
 2. PLEASE PROVIDE A FIXTURE PLAN. IN CLASS C MERCANTILE
 OCCUPANCIES, A SINGLE MEANS OF EGRESS IS PERMITTED AS
 LONG AS THE TRAVEL DISTANCE DOES NOT EXCEED 75 FEET.
 PLEASE ILLUSTRATE FIXTURES AND TRAVEL DISTANCE TO THE
 SINGLE EXIT.
  
 3. PLEASE INDICATE INTERIOR FINISH CLASSIFICATIONS FOR
 WALLS AND CEILINGS.
  
 4. TACTILE SIGNAGE REQUIRED AT EXIT DOOR.
  
 5. THE PLANS DO NOT INDICATE THE LOCATIONS OF ANY
 EXISTING OR NEW PORTABLE FIRE EXTINGUISHERS.
  
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-05-26 Cont ID  
Sent By lmartine Date 2011-05-23 Time 13:55 Rev Time 0.00
Received By lmartine Date 2011-05-04 Time 16:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-04 Cont ID  
Sent By jwitmer Date 2011-04-20 Time 16:51 Rev Time 0.00
Received By jwitmer Date 2011-03-28 Time 15:56 Sent To  
Notes
2011-03-28 15:56:38SENT TO B1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-06 Cont ID  
Sent By hmoser Date 2011-01-06 Time 11:09 Rev Time 0.00
Received By hmoser Date 2010-12-21 Time 07:38 Sent To  
Notes
2010-12-21 07:44:43B21

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-04-05 Cont ID  
Sent By hmoser Date 2011-04-05 Time 12:02 Rev Time 0.00
Received By hmoser Date 2011-04-05 Time 11:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-01-06 Cont ID  
Sent By hmoser Date 2011-01-06 Time 11:08 Rev Time 0.00
Received By hmoser Date 2011-01-06 Time 08:38 Sent To  
Notes
2011-01-06 08:44:271. NOTES ON PLAN PROVIDED REFER TO MECHANICAL PLANS AND
 SPECIFICATIONS BY THE MECHANICAL ENGINEER. NO
 MECHANICAL PLANS PROVIDED. PROVIDE MECHANICAL PLANS
 SHOWING SCOPE OF WORK AND ALL INFORMATION REQUIRED TO
 SHOW CODE COMPLIANCE SUCH AS EQUIPMENT, EQUIPMENT
 LOCATION, WIND RESISTANCE, VENTILATION REQUIRED, ETC.
 REVISE OTHER SHEETS IF NECESSARY FOR CONSISTENCY.
  
 DENIED
  
 HAROLD MOSER, MECHANICAL PLANS EXAMINER
 561-805-6732
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2011-05-06 Cont ID  
Sent By lwagner Date 2011-05-06 Time 15:04 Rev Time 0.00
Received By lwagner Date 2011-05-06 Time 14:33 Sent To  
Notes
2011-05-06 15:04:04THE DRINKING FOUNTAIN HAS BEEN REMOVED PER EXISTING
 BUILDING 710.1

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-04-04 Cont ID  
Sent By lwagner Date 2011-04-04 Time 10:14 Rev Time 0.00
Received By lwagner Date 2011-04-04 Time 09:13 Sent To  
Notes
2011-04-04 10:16:30REVISION REQUIRED FOR LOCATION OF DRINKING FOUNTAIN AND
 ADDITION OF DRINKING FOUNTAIN TO SANITARY ISOMETRIC
 DRAWING.
 PLUMBING PERMIT REQUIRED
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2010-12-28 Cont ID  
Sent By lwagner Date 2010-12-28 Time 10:19 Rev Time 0.00
Received By lwagner Date 2010-12-28 Time 09:52 Sent To  
Notes
2010-12-28 10:22:17SEPERATE PLUMBING PERMIT, PLAN, AND APPLICATION
 REQUIRED

Review Stop Z ZONING
Rev No 3 Status P Date 2011-05-23 Cont ID  
Sent By astelly Date 2011-05-23 Time 11:10 Rev Time 0.00
Received By astelly Date 2011-05-23 Time 11:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2011-04-20 Cont ID  
Sent By astelly Date 2011-04-20 Time 13:33 Rev Time 0.00
Received By astelly Date 2011-04-20 Time 13:33 Sent To  
Notes
2011-04-20 15:57:24AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 REPEAT COMMENT
 PLEASE PROVIDE A SURVEY OF THE SITE.
  
 IN ACCORDANCE WITH SEC. 94-305:
 WINDOW AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN
 18 INCHES INTO A REQUIRED SIDE SETBACK. PLEASE NOTE THE
 DISTANCE THAT THE UNIT PROJECTS FROM THE WALL.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2011-01-13 Cont ID  
Sent By astelly Date 2011-01-13 Time 17:17 Rev Time 0.00
Received By astelly Date 2011-01-13 Time 17:17 Sent To  
Notes
2011-01-27 18:01:14AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PLEASE PROVIDE A SURVEY OF THE SITE. AERIAL PHOTOS
 INDICATE THAT THE MECHANICAL UNIT MAY BE ENCROACHING ON
 ANOTHER PARCEL.