| Plan Review Stops For Permit 10120466 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-12-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-12-29 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-12-29 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-12-22 |
Time |
11:54 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2010-12-22 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2010-12-22 11:56:38 | BUILDING PLAN APPEAR TO BE CODE COMPLIANT, EACH OF THE | | | TRADES NEED THE QUALIFIER TO SIGN AND APPLY THEIR | | | LICENSE NUMBER TO THE PLANS. JW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-12-29 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-29 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-12-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-20 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2010-12-20 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2010-12-20 09:14:33 | LOCATE SMOKE DETECTORS ON THE PLAN. INDICATE THEY ARE | | | TO BE INTERCONNECTED. FBC 907.2.10 | | | SHOW LOCATION OF EXISTING PANEL BOARD. PROVIDE SIZE AND | | | RATING OF THE NEW PANEL BOARD. SHOW EXISTING SERVICE | | | WIRE SIZE AND OVERCURRENT PROTECTION PROVIDED AT THE | | | MAIN SERVICE DISTRIBUTION. PROVIDE A PANEL SCHEDULE | | | SHOWING ALL CIRCUITS NEW AND EXISTING WITH CIRCUIT | | | BREAKERS AND WIRE SIZES. NEC 210.2, 230.3, 240.4 | | | | | | ROBERT LECKY, PLANS EXAMINER, 561-805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2010-12-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-12-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-12-29 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2010-12-29 14:40:47 | SMOKE ALARMS ARE TO BE TESTED TO ENSURE PROPER | | | OPERATION. THEY SHALL BE INSTALLED A MINIMUM OF AT | | | LEAST THREE FEET FROM AIR CONDITIONER DIFFUSERS. PLANS | | | INDICATE THEY WILL BE INTERCONNECTED. | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-01-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-06 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-20 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-10 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-10 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2011-01-10 08:07:14 | OK PER HM | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-01-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-01-06 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-01-06 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2011-01-06 08:58:16 | 1. THE NAME OF THE DESIGNER OF THE PLAN, DAVID | | | HUTCHISON, DOES NOT MATCH THE LICENSE NUMBER OF THE | | | PLAN (CAC1814987). PLANS ARE TO BE PREPARED BY AN | | | INDIVIDUAL LICENSED TO DESIGN THIS SCOPE OF WORK, | | | FLORIDA STATUTE 471, FS481, FS489. | | | | | | 2. COMBUSTIBLES NOT PERMITTED IN A RETURN AIR PLENUM, | | | FBC MECHANICAL 602.2.1. | | | | | | HAROLD MOSER, MECHANICAL PLANS EXAMINER | | | 561-805-6732 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-12-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-12-30 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-12-30 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2010-12-30 14:16:01 | ISO ADDED TO PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-12-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-12-27 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-12-27 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2010-12-27 10:21:35 | FBC PLUMBING 2007 REVIEW #1 | | | DENIED: | | | | | | PAGE 5 OF SCOPE INDICATES RUNNING A 3" WASTE LINE AND | | | WATER LINES. | | | FBC 106.3.5.1.3 MINIMUM CRITERIA PLUMBING RISER DIAGRAM | | | REQUIRED. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2010-12-20 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2010-12-20 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|