| Plan Review Stops For Permit 10120447 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-01-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-01-05 |
Time |
08:43 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2011-01-04 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2011-01-05 08:51:48 | BUILDING PLAN REVIEW | | | PERMIT: 10120447 | | | ADD: 10130 NORTHLAKE BLVD SUITE 100& 102 | | | CONT: S.W.KAPER | | | TEL: (561)847-6648 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | 1008.1.9 PANIC AND FIRE EXIT HARDWARE. WHERE PANIC AND | | | FIRE EXIT HARDWARE IS INSTALLED, IT SHALL COMPLY WITH | | | THE FOLLOWING: | | | 1. THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL | | | EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. | | | 2. THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 | | | POUNDS (67 N). | | | EACH DOOR IN A MEANS OF EGRESS FROM A GROUP A OR E | | | OCCUPANCY HAVING AN OCCUPANT LOAD OF 50 OR MORE AND ANY | | | GROUP H OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR | | | LOCK UNLESS IT IS PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-01-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-01-03 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-01-03 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-01-10 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2011-01-10 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2011-01-10 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2011-01-10 14:08:59 | 1/10/11 PLANS REVIEWED BY CAPTAIN DANIELS PASSED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-12-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-12-21 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-12-21 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2010-12-21 15:08:57 | MIJAS TEX MEX RESTAURANT | | | 10130 NORTHLAKE BOULEVARD, SUITE 102 | | | PERMIT NUMBER 10120447 | | | | | | | | | 1. ALL CONSTRUCTION, DEMOLITION, AND RENOVATION TO | | | COMPLY WITH NFPA 241. | | | | | | 2. SEPARATE PLANS AND PERMITS REQUIRED FOR NEW HOOD, | | | DUCT, AND FIRE SUPPRESSION SYSTEM. | | | | | | 3. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS. | | | | | | 4. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER SYSTEM REMODEL. PLEASE ENSURE FIRE SPRINKLER | | | PROTECTION IN EXISTING WALK-IN COOLER. | | | | | | 5. NEW GAS LINE TO BE INSTALLED IN ACCORDANCE WITH | | | APPLICABLE STANDARDS AND IN A SAFE RELIABLE MANNER. | | | | | | 6. PLEASE ENSURE THAT ALL EXIT SIGNS AND EMERGENCY | | | LIGHTS ARE IN GOOD WORKING ORDER. | | | | | | 7. ON SEVERAL SHEETS THE BACKS OF THE SEATS APPEAR TOO | | | CLOSE TOGETHER IN EXISTING DINING AREA 103. | | | | | | 8. ALL EXIT DOORS SUBJECT TO AN OCCUPANCY LOAD OF 100 | | | OR MORE PERSONS SHALL BE EQUIPPED WITH PANIC HARDWARE. | | | | | | 9. IS THE EXISTING OUTDOOR DINING AREA 104 HAVE A ROOF | | | OR IS IT OPEN TO THE SKY? | | | | | | | | | DENIED | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2010-12-28 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-12-28 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-12-27 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2010-12-27 14:22:22 | *****PROVISO***** | | | | | | 404.11 PIPING UNDERGROUND BENEATH BUILDINGS. | | | PIPING INSTALLED UNDERGROUND BENEATH BUILDINGS | | | IS PROHIBITED EXCEPT WHERE THE PIPING IS | | | ENCASED IN A CONDUIT OF WROUGHT IRON, PLASTIC | | | PIPE, OR STEEL PIPE DESIGNED TO WITHSTAND THE | | | SUPERIMPOSED LOADS. SUCH CONDUIT SHALL EXTEND | | | INTO AN OCCUPIABLE PORTION OF THE BUILDING AND, | | | AT THE POINT WHERE THE CONDUIT TERMINATES IN | | | THE BUILDING, THE SPACE BETWEEN THE CONDUIT | | | AND THE GAS PIPING SHALL BE SEALED TO PREVENT | | | THE POSSIBLE ENTRANCE OF ANY GAS LEAKAGE. | | | WHERE THE END SEALING IS CAPABLE OF | | | WITHSTANDING THE FULL PRESSURE OF THE GAS PIPE, | | | THE CONDUIT SHALL BE DESIGNED FOR THE SAME | | | PRESSURE AS THE PIPE. SUCH CONDUIT SHALL EXTEND | | | NOT LESS THAN 4 INCHES (102 MM) OUTSIDE THE | | | BUILDING, SHALL BE VENTED ABOVE GRADE TO THE | | | OUTDOORS, AND SHALL BE INSTALLED SO AS TO PREVENT | | | THE ENTRANCE OF WATER AND INSECTS. THE CONDUIT | | | SHALL BE PROTECTED FROM CORROSION IN ACCORDANCE | | | WITH SECTION 404.8. | | | | | | PLUMBING PERMIT REQUIRED | | | GAS PERMIT REQUIRED | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-01-10 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2011-01-10 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2011-01-07 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2011-01-07 15:22:27 | INCOMING SENT SUBMITTAL AND PLANS TO FIRE BOX. JW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-01-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-01-06 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-12-16 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-01-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-01-06 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-01-06 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-12-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-12-27 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-12-27 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-12-30 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-12-30 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-12-30 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2010-12-30 11:40:59 | PLANNING AND ZONING: **** ZONING REVIEW NOT REQUIRED: | | | INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES | | | NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** |
|
|