Plan Review Details - Permit 10120405
| Plan Review Stops For Permit 10120405 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-01-19 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2011-01-19 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2011-01-19 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2011-01-19 13:43:11 | 1/19/11 PLANS REVIEWED BY CAPTAIN DANIELS | | | ALL COMMENTS ADDRESSED | | | PASSED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-12-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-12-17 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-12-17 |
Time |
12:07 |
Sent To |
M |
|
| Notes |
| 2010-12-17 14:15:55 | 1000--45TH STREET, BUILDING #1 | | | PERMIT #10120405 | | | REVIEW COMMENTS - FIRE | | | | | | | | | PROVIDE SIGNAGE AT THE FIRE DEPARTMENT CONNECTIONS | | | IDENTIFYING WHICH CONNECTIONS SUPPLY WHICH BUILDING. | | | | | | PROVIDE A LOCAL WATERFLOW ALARM. THIS ALARM SHALL ALSO | | | BE TIED INTO THE BUILDING FIRE ALARM SYSTEM PER SECTION | | | 6.6.8.1 OF NFPA 13R. | | | | | | PROVIDE SPRINKLER PROTECTION IN THE SPRINKLER RISER | | | ROOM. | | | | | | PAGE 5 OF THE HYDRAULIC CALCULATIONS IS MISSING. PAGE 5 | | | SHOWS THE CONNECTION OF THE NODES, FRICTION LOSS, ETC. | | | | | | NOTE: THE SPRINKLER SYSTEM HAS BEEN DESIGNED TO NFPA | | | 13R. THE SPRINKLER SYSTEM HYDRAULICS HAVE BEEN | | | CONSERVATIVELY DESIGNED TO NFPA 13 STANDARDS USING A | | | DESIGN DENSITY OF 0.10 GPM/SQ.FT. IN LIEU OF THE | | | SPECIFIC LISTED FLOW REQUIREMENTS (BASED UPON MAXIMUM | | | SPRINKLER COVERAGE) OF NFPA 13R. THE SPECIFIC FLOW FOR | | | 16 FT. X 16 FT. SPRINKLER COVERAGE IS SHOWN AS 13 GPM | | | IN THE PRODUCT DATA. A DESIGN DENSITY OF 0.10 | | | GPM/SQ.FT. FOR 16 FT. X 16 FT. RESULTS IN A COVERAGE | | | AREA OF 256 SQ.FT. EQUATING TO 25.6 GPM. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-01-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-01-18 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-01-18 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2011-01-18 14:46:31 | IN FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-12-28 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-12-15 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2010-12-15 16:48:40 | IN FIRE BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-12-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-12-28 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-12-28 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
|