Plan Review Details - Permit 10120201
| Plan Review Stops For Permit 10120201 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-13 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-13 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2011-01-13 11:18:10 | POOL FENCE AND ALARMS SHALL COMPLY WITH FBC R4101.17 | | | RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-16 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-16 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2010-12-16 11:05:30 | DENIED BY BUILDING | | | | | | 1) SHOW COMPLIANCE WITH FBC R4101.17 RESIDENTIAL POOL | | | BARRIER REQUIREMENT. IN ADDITION TO THE EXIT ALARM | | | COMPLYING WITH UL 2017 (2000 EDITION) REQUIRED BY | | | R4101.17.1.9 WHERE THE WALL OF A DWELLING SERVES AS | | | PART OF THE BARRIER, THE POOL IS REQUIRED TO BE | | | ENCLOSED BY A FENCE ON THE REMAINING SIDES. | | | | | | 2) PROVIDE A CROSS SECTION OF THE PROPOSED POOL SHOWING | | | THE DEPTHS AND BOTTOM CONTOUR. | | | | | | 3) PROVIDE A DETAIL ON THE PLANS SPECIFYING HOW THE | | | POOL EQUIPMENT WILL BE ANCHORED TO RESIST THE 140 MPH 3 | | | SECOND GUST WIND SPEED. FBC R301.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-16 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-16 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2010-12-16 14:14:05 | PROVISO | | | | | | A GFCI PROTECTED GENERAL PURPOSE RECEPTACLE IS REQUIRED | | | BETWEEN 6 FT AND 20 FT OF THE INSIDE WALL OF THE POOL. | | | NEC 680.22 (A)(3) |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-16 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-16 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2010-12-16 09:42:57 | NO GAS DRAWINGS SHOWN ON PLANS. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-12-08 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2010-12-08 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2010-12-08 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-16 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-09 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2010-12-09 16:48:10 | IN SWIMMING POOL BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-13 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-13 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-16 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-16 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2010-12-16 13:48:13 | DENIED BY PLUMBING | | | | | | 2004 FBC W/2009 REVISIONS | | | RESIDENTIAL POOL | | | | | | DENIED BY PLUMBING | | | | | | 1) THE SIMPLIFIED TDH CALCULATIONS SPECIFY A 3/4 HP | | | PENTAIR POOL PUMP AND THE LANDSCAPE AND POOL PLAN | | | SPECIFIES A 1 HP PENTAIR PUMP. SUBMIT 2 COPIES OF THE | | | SPECIFICATIONS FOR THE POOL PUMP INCLUDING THE PUMP | | | CURVE FOR THE PUMP THAT WILL BE INSTALLED. IF A | | | VARIABLE SPEED OR TWO SPEED PUMP IS USED USE THE MAX. | | | PUMP FLOW IN CALCULATIONS. | | | | | | 2) THE PENTAIR SUPERFLO SERIES 3/4 HP PUMP AT HIGH | | | SPEED HAS A FLOW RATE OF ABOUT 65 GPM WITH A TDH OF | | | 21.3. AT 65 GPM IN 1-1/2" PIPE THE WATER VELOCITY IS | | | 10.23 FPS. WHICH EXCEEDS THE 6 FPS ALLOWED IN MAIN | | | DRAIN BRANCH PIPING. EVEN AT THE 33 GPM SPECIFIED ON | | | THE PLANS THE VELOCITY IS 13 GPM IN 1" PIPE, WHICH | | | EXCEEDS THE 8 FPS ALLOWED IN THE SUCTION LINE AND THE | | | 10 FPS ALLOWED IN THE RETURN LINES. PLEASE CORRECT. | | | | | | 3) PROVIDE TWO SETS OF A POOL PLAN THAT INDICATES THE | | | LOCATIONS OF THE MAIN DRAINS, THE RETURNS, SKIMMER, | | | POOL LIGHT, ETC. | | | | | | 4) IF A POOL HEATER WILL BE INSTALLED, SUBMIT TWO SETS | | | OF MANUFACTURER'S SPECIFICATIONS FOR THE HEATER | | | INDICATING THE ELECTRICAL OR GAS REQUIREMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-12-08 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2010-12-08 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2010-12-08 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
|