| Plan Review Stops For Permit 10110685 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-03-14 |
Time |
09:54 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2011-03-14 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2011-03-14 10:08:47 | BUILDING PLAN REVIEW | | | PERMIT:10110685 | | | ADD: 410 EVERNIA ST | | | CONT:BESSENROTH BUILDERS INC/ CBC1255316 | | | TEL: (561)324-4871 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | BUILDING PROVISO: | | | THE CURRENT CONTRACTOR BESSENROTH BUILDERS/ CBC1255316 | | | WILL ONLY BE LIMITED TO CUTTING THE FIRST FLOOR SLAB, | | | NO SAW CUTTING OR REMOVAL OF MEZZANINE SLAB WITH A CBC | | | LICENSE, OTHERWISE IT WOULD BE WORKING BEYOND THEIR | | | SCOPE OF LICENSURE. FL S 489.105(B) BUILDING | | | CONTRACTOR. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-01-28 |
Time |
10:18 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2011-03-14 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2011-01-28 10:41:46 | BUILDING PLAN REVIEW | | | PERMIT:10110685 | | | ADD: 410 EVERNIA ST | | | CONT:BESSENROTH BUILDERS INC/ CBC1255316 | | | TEL: (561)324-4871 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) THERE ARE NO ARCHITECTURAL PLANS SUBMITTED | | | INDICATING SLAB CUT AND REPAIR FOR PLUMBING WASTE PIPES | | | NOR HOW VENT LINES TO BE INSTALLED. | | | | | | 2) THE PLANS FAIL TO PROVIDE VERTICAL ACCESSIBILITY TO | | | THE MEZZANINE LEVEL, THIS BUILDING WAS ORIGINALLY | | | DESIGNED AS RESIDENTIAL NOT REQUIRING | | | VERTICAL ACCESSIBILITY. 11-4.1.6(1)(K)(III). | | | | | | 3) THE CURERNT CONTRACTOR BESSENROTH BUILDERS/ | | | CBC1255316 WILL BE WORKING BEYOND THEIR SCOPE OF | | | LICENSURE. FL S 489.105(B) | | | BUILDING CONTRACTOR??? MEANS A CONTRACTOR WHOSE | | | SERVICES ARE LIMITED TO CONSTRUCTION OF COMMERCIAL | | | BUILDINGS AND SINGLE-DWELLING OR MULTIPLE-DWELLING | | | RESIDENTIAL BUILDINGS, WHICH COMMERCIAL OR RESIDENTIAL | | | BUILDINGS DO NOT EXCEED THREE STORIES IN HEIGHT, AND | | | ACCESSORY USE STRUCTURES IN CONNECTION THEREWITH OR A | | | CONTRACTOR WHOSE SERVICES ARE LIMITED TO REMODELING, | | | REPAIR, OR IMPROVEMENT OF ANY SIZE BUILDING IF THE | | | SERVICES "DO NOT AFFECT THE STRUCTURAL MEMBERS OF THE | | | BUILDING." WE BELIEVE THAT CUTTING THE FIRST FLOOR SLAB | | | AND CORE BORING THE MEZZANINE FLOOR SLAB WOULD BE | | | AFFECTING STRUCTURAL MEMBERS. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-12-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-12-13 |
Time |
14:58 |
Rev Time |
0.56 |
| Received By |
jwitmer |
Date |
2010-12-13 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2010-12-13 15:03:14 | BUILDING PLAN REVIEW | | | PERMIT:10110685 | | | ADD: 410 EVERNIA ST | | | CONT: DELCO CONSTRUCTION | | | TEL: (561)436-4106 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) THERE ARE NO ARCHITECTURAL PLANS SUBMITTED | | | INDICATING SLAB CUT AND REPAIR FOR PLUMBING WASTE PIPES | | | NOR HOW VENT LINES TO BE INSTALLED. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-03-15 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-03-15 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-03-15 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-12-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-12-06 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-12-06 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2010-12-06 10:19:40 | SEE NOTES ON PLAN FOR EMERGENCY CIRCUITS , LIGHTING | | | SPACE CONTROL, AND RESIDENTIAL LOAD CALCULATION | | | | | | JAKE LEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-02-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-02-03 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-02-03 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2011-02-03 12:22:34 | 410 EVERNIA STREET, SUITE #117 | | | PERMIT #10110685 | | | REVIEW COMMENTS - FIRE | | | | | | NOTE: DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY | | | THE FIRE DEPARTMENT AFTER ALL PLAN REVIEWER COMMENTS | | | HAVE BEEN SATISFIED. | | | | | | PROVIDE SEPARATE PLANS AND PERMITS FOR ANY FIRE ALARM | | | AND FIRE SPRINKLER INSTALLATION OR MODIFICATIONS. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-12-16 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-12-16 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2010-12-16 16:53:30 | 410 EVERNIA STREET SUITE#117 | | | PERMIT #10110685 | | | REVIEW COMMENTS - FIRE | | | | | | PERMIT APPLICATION SHOWS SUITE NUMBER 117; SUBMITTED | | | PLANS REFER TO LOFT NUMBER 5. PLEASE CLARIFY THE | | | CORRECT SUITE OR LOFT ASSOCIATED WITH THIS PROJECT. | | | | | | IS THIS A CHANGE OF USE OR OCCUPANCY FOR THIS SUITE? | | | FLOOR PLANS DO NOT LABEL THE NAMES OR USE OF EACH ROOM. | | | NO ARCHITECTURAL PLANS PROVIDED. | | | | | | THE EXISTING RESIDENTIAL FIRE SPRINKLERS NEED TO BE | | | REPLACED WITH COMMERCIAL STYLE FIRE SPRINKLERS. | | | SEPARATE PLANS AND PERMIT REQUIRED FOR FIRE SPRINKLER | | | WORK. | | | | | | PROVIDE COMMERCIALLY TAGGED/CERTIFIED PORTABLE FIRE | | | EXTINGUISHERS (2A:10BC MIIMUM). | | | | | | EXITING THROUGH A KITCHEN IS NOT PERMITTED BY THE | | | FLORIDA FIRE PREVENTION CODE (NFPA 101 - LIFE SAFETY | | | CODE). | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-03-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-03-18 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-09 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-01-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-01-19 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-01-19 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-22 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-30 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2010-12-22 16:39:50 | ON MISC 3 | | 2010-12-09 14:45:44 | B24 | | | | | 2010-11-30 11:12:56 | INCOMING SENT TO PLUMBING <$5,000.00 JW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-03-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-03-18 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-18 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2011-03-18 09:41:20 | SEE #10110685 FOR HAROLD'S APPROVAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-02-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-02-15 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-02-15 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2011-02-15 11:26:02 | NO MECHANICAL PLANS SUBMITTED . NEED PLANS FOR NAIL | | | STATIONS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2011-03-14 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-03-14 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-03-14 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2011-03-14 10:19:27 | REVISION REQUIRED | | | | | | 1. THIS AREA OF PLUMBING HAS A MIXTURE OF WASTE STACK | | | VENTING AND SOVENT PIPING. | | | SOVENT IS AN ENGINEERED SYSTEM. CONNECTIONS DOWNSTREAM | | | OF THE DEAERATOR VENT MAY BE MADE WITHOUT | | | RE-ENGINEERING THE SYSTEM. CONNECTING INTO THE BUILDING | | | DRAIN OR BUILDING DRAIN BRANCHES WOULD ALSO BE | | | PERMISSIBLE. | | | | | | 2. IF STUDOR VENTS ARE USED, THEN A RELIEF VENT WILL BE | | | REQUIRED. | | | 917.3.2 | | 2011-03-14 10:18:26 | REVISION REQUIRED | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2011-01-31 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-01-31 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-01-31 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2011-01-31 10:39:10 | FBC PLUMBING 2007 REVIEW #2 | | | DENIED: | | | | | | 1. STUDOR VENTS ARE SHOWN ON PLAN. THE DRAINAGE SYSTEM | | | FOR THIS BUILDING IS OVER 4 BRANCH INTERVALS ABOVE. | | | 917.3.2 A RELIEF VENT WOULD BE REQUIRED. | | | | | | 2. THE RISER DIAGRAM DOES NOT SHOW WHERE THE SANITARY | | | PIPEING IS BEING CONNECTED. THIS AREA OF PLUMBING HAS A | | | MIXTURE OF WASTE STACK VENTING AND SOVENT PIPING. | | | SOVENT IS AN ENGINEERED SYSTEM. CONNECTIONS DOWNSTREAM | | | OF THE DEAERATOR VENT MAY BE MADE WITHOUT | | | RE-ENGINEERING THE SYSTEM. CONNECTING INTO THE BUILDING | | | DRAIN OR BUILDING DRAIN BRANCHES WOULD ALSO BE | | | PERMISSIBLE. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-12-06 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-12-06 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-12-06 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2010-12-06 08:19:15 | PBC PLUMBING 2007 REVIEW #1 | | | DENIED: | | | | | | 1. PLUMBING 403.1 MINIMUM PLUMBING FIXTURES: 1 DRINKING | | | FOUNTAIN WILL BE REQUIRED. | | | | | | 2. RESTROOM IS REQUIRED TO MEET FBC BUILDING 2007 | | | CHAPTER 11 - FLORIDA ACCESSIBILITY CODE FOR BUILDING | | | CONSTRUCTION. | | | | | | 3. BUILDING CHAPTER 106.3.5 MINIMUM PLAN REVIEW | | | CRITERIA FOR BUILDINGS- 13. PLUMBING RISER DIAGRAM | | | REQUIRED( SANITARY AND DOMESTIC WATER). | | | | | | 4. PLUMBING FLAT DRAWING SHOWS DRAINAGE FOR 2 SHAMPOO | | | CHAIRS WITH NO VENT. PLUMBING CHAPTER 901.2.1 VENTING | | | REQUIRED. EVERY TRAP AND TRAPPED FIXTURE SHALL BE | | | VENTED IN ACCORDANCE WITH ONE OF THE VENTING METHODS | | | SPECIFIED IN THIS CHAPTER. | | | | | | NOTE: NO ARCHITECTURAL PLANS WERE SUBMITTED WITH THIS | | | SET | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2010-12-22 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2010-12-22 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2010-12-22 10:20:54 | PUT IN ZONING BOX TO MAKE ROOM ON BUILD OUT SPREAD | | | SHEET |
|
|