Plan Review Details - Permit 10110434
Plan Review Stops For Permit 10110434
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-11-18 Cont ID  
Sent By jwitmer Date 2010-11-18 Time 14:22 Rev Time 0.66
Received By jwitmer Date 2010-11-18 Time 11:06 Sent To  
Notes
2010-11-18 14:22:49BUILDING PLAN REVIEW
 PERMIT: 10110434
 ADD: 507 N OLIVE SUITE# R507
 CONT: PHOENIX REALITY HOMES
 TEL: (561)307-6112
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) RECEPTION COUNTER NO DETAILS ON HEIGHT PROVIDED WILL
 NEED TO MEET 2007 FBC 11-7.2(2)
 AT TICKETING COUNTERS THAT MAY NOT HAVE A CASH REGISTER
 BUT AT WHICH GOODS OR SERVICES ARE SOLD OR DISTRIBUTED,
 EITHER:
 (I) A PORTION OF THE MAIN COUNTER WHICH IS A MINIMUM OF
 36 INCHES (915 MM) IN LENGTH SHALL BE PROVIDED WITH A
 MAXIMUM HEIGHT OF 36 INCHES (915 MM); OR
 (II) AN AUXILIARY COUNTER WITH A MAXIMUM HEIGHT OF 36
 IN (915 MM) IN CLOSE PROXIMITY TO THE MAIN COUNTER
 SHALL BE PROVIDED; OR
 (III) EQUIVALENT FACILITATION SHALL BE PROVIDED (E.G.,
 AT A HOTEL REGISTRATION COUNTER, EQUIVALENT
 FACILITATION MIGHT CONSIST OF:
 (1) PROVISION OF A FOLDING SHELF ATTACHED TO THE MAIN
 COUNTER ON WHICH AN INDIVIDUAL WITH DISABILITIES CAN
 WRITE, AND
 (2) USE OF THE SPACE ON THE SIDE OF THE COUNTER OR AT
 THE CONCIERGE DESK, FOR HANDING MATERIALS BACK AND
 FORTH).
  
 2) ROOM 106 STAFF BREAK ROOM SINK TO COMPLY WITH:
 11-4.24 SINKS.
 11-4.24.1 GENERAL. SINKS REQUIRED TO BE ACCESSIBLE BY
 SECTION 11-4.1 SHALL COMPLY WITH SECTION 11-4.24.
 11-4.24.2 HEIGHT. SINKS SHALL BE MOUNTED WITH THE
 COUNTER OR RIM NO HIGHER THAN 34 INCHES (865 MM) ABOVE
 THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE. KNEE CLEARANCE THAT IS AT
 LEAST 27 INCHES (685 MM) HIGH, 30 INCHES (760 MM) WIDE,
 AND 19 INCHES (485 MM) DEEP SHALL BE PROVIDED
 UNDERNEATH SINKS.
 11-4.24.4 DEPTH. EACH SINK SHALL BE A MAXIMUM OF 61/2
 INCHES (165 MM) DEEP.
 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT
 LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM)
 COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN
 FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR
 FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL
 EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE
 SINK (SEE FIGURE 32).
 11-4.24.6 EXPOSED PIPES AND SURFACES. HOT WATER AND
 DRAIN PIPES EXPOSED UNDER SINKS SHALL BE INSULATED OR
 OTHERWISE CONFIGURED SO AS TO PROTECT AGAINST CONTACT.
 THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER
 SINKS.
 11-4.24.7 FAUCETS. FAUCETS SHALL COMPLY WITH SECTION
 11-4.27.4. LEVER-OPERATED, PUSH-TYPE, TOUCH-TYPE, OR
 ELECTRONICALLY CONTROLLED MECHANISMS ARE ACCEPTABLE
 DESIGNS.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-11-18 Cont ID  
Sent By jdickins Date 2010-11-18 Time 17:33 Rev Time 0.00
Received By jdickins Date 2010-11-18 Time 17:33 Sent To  
Notes
2010-11-18 17:33:39OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER,LICENSE
 NUMBER PX3182

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2010-12-08 Cont ID  
Sent By wjolin Date 2010-12-08 Time 14:12 Rev Time 0.00
Received By wjolin Date 2010-12-08 Time 14:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-12-09 Cont ID  
Sent By lwagner Date 2010-12-09 Time 08:12 Rev Time 0.00
Received By lwagner Date 2010-11-16 Time 15:56 Sent To  
Notes
2010-11-16 15:57:27****************EXPEDITED****************
 B--17

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-12-03 Cont ID  
Sent By hmoser Date 2010-12-03 Time 13:19 Rev Time 0.00
Received By hmoser Date 2010-12-03 Time 10:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-12-09 Cont ID  
Sent By lwagner Date 2010-12-09 Time 08:11 Rev Time 0.00
Received By lwagner Date 2010-12-09 Time 08:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-11-19 Cont ID  
Sent By lwagner Date 2010-11-19 Time 07:51 Rev Time 0.00
Received By lwagner Date 2010-11-19 Time 07:26 Sent To  
Notes
2010-11-19 07:49:00FBC PLUMBING 2007 REVIEW #1
 DENIED:
  
 1. THE HUB DRAIN FOR THE WATER HEATER PAN DRAIN WILL
 REQUIRE A TRAP PRIMER.
 1002.4 TRAP SEALS. . . WHERE A TRAP SEAL IS SUBJECT TO
 LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE
 INSTALLED. A TRAP SEAL PRIMER VALVE SHALL CONFORM TO
 ASSE 1018 OR ASSE 1044.
  
 2. BUSINESS OCCUPANCIES REQUIRE A MINIMUM OF ONE
 DRINKING FOUNTAIN.
 403.1 MINIMUM NUMBER OF FIXTURES. DRINKING FOUNTAINS -
 BUSINESS: 1 PER 100
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2010-12-01 Cont ID  
Sent By aaponte Date 2010-12-01 Time 15:16 Rev Time 0.00
Received By aaponte Date 2010-12-01 Time 15:16 Sent To  
Notes
***NONE***