Plan Review Details - Permit 10110420
| Plan Review Stops For Permit 10110420 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-01-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-01-14 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-01-14 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2011-01-14 12:36:03 | LOW VOLTAGE SECURITY CAMERA SUBMITTAL STAMPED AND | | | RELEASED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-11-22 |
|
|
Cont ID |
|
| Sent By |
jdickins |
Date |
2010-11-22 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
jdickins |
Date |
2010-11-22 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2010-11-22 18:22:41 | OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE | | | NUMBER PX3182 | | | NOTE: | | | SEPERATE ELECTRICAL PERMIT REQUIRED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-12-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-12-14 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-12-14 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2010-12-14 15:18:15 | 1920 WEKIVA WAY | | | PERMIT #10110420 | | | REVIEW COMMENTS - FIRE | | | APPROVED PROVISO | | | | | | SECOND FLOOR ACCESS CONTROL: | | | | | | NO LOCKS (MAG LOCKS, KEYED LOCKS ETC.) PERMITTED ON | | | CORRIDOR DOORS #225A OR #247A. EGRESS SHALL BE FREE AT | | | ALL TIMES. | | | | | | SECTION 7.4.1.6 OF THE FLORIDA FIRE PREVENTION CODE | | | (NFPA 101 - 2006 EDITION WITH FLORIDA AMENDMENTS) | | | REQUIRES ELEVATOR LOBBIES TO HAVE UNRESTRICTED ACCESS | | | TO EXTIS. EXIT ACCESS SHALL NOT REQUIRE THE USE OF A | | | KEY, TOOL, SPECIAL KNOWLEDGE OR SPECIAL EFFORT. | | | | | | UNRESTRICTED ACCESS TO TWO EXITS SHALL BE AVAILABLE TO | | | ALL OCCUPANTS AT ALL TIMES. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-11-19 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-11-19 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-11-19 |
Time |
16:00 |
Sent To |
E |
|
| Notes |
| 2010-11-19 16:21:12 | 1920 WEKIVA WAY | | | PERMIT #10110420 | | | MASTER #10070788 | | | REVIEW COMMENTS - FIRE | | | | | | NO MANUAL RELEASE BUTTON HAS BEEN PROVIDED INSIDE | | | STORAGE ROOM 121. | | | | | | THE ACCESS CONTROL SYSTEM DEVICES ARE NOT PERMITTED | | | INSIDE THE STAIRS. | | | | | | UPON EXITING THE ELEVATORS ON THE SECOND FLOOR, THE | | | DOORS ARE LOCKED IN THE PATH OF EGRESS TO STAIR 1 AND | | | STAIR 2. THIS IS NOT PERMITTED PER THE REQUIRMENTS OF | | | ACCESS-CONTROLLED EGRESS DOORS. | | | | | | NO MANUAL RELEASE BUTTONS HAVE BEEN PROVIDED ON THE | | | SECOND FLOOR. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-01-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-01-14 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-12-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-12-14 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-12-13 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2010-12-13 14:22:47 | TO FIRE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-29 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-18 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2010-11-18 15:15:07 | IN FIRE BOX |
|
|
|