Plan Review Details - Permit 10110291
Plan Review Stops For Permit 10110291
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-12-27 Cont ID  
Sent By jwitmer Date 2010-12-27 Time 15:13 Rev Time 0.33
Received By jwitmer Date 2010-12-27 Time 15:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-11-19 Cont ID  
Sent By jwitmer Date 2010-11-19 Time 10:50 Rev Time 0.77
Received By jwitmer Date 2010-11-19 Time 10:50 Sent To  
Notes
2010-11-19 10:58:46BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 PLANS DO NOT INDICATE ANY INFORMATION ON THE NEW FRAMED
 METAL STUD WALL. PLEASE PROVIDE THE SIZE (WIDTH) OF
 STEEL STUD, GUAGE OF STUD, AND SPACING OF STEEL STUDS
 AND THE DESIGN CRITERIA, MINIMUM DESIGN LOAD, AND
 MAXIMUM ALLOWABLE DEFECTION.
 2007 FBC- BUILDING/ 2009 REVISIONS SECTION 2508.1,
 TABLE 2508.1 & ASME C754-04 STEEL FRAMING FOR STEEL
 STUDS.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-12-28 Cont ID  
Sent By rlecky Date 2010-12-28 Time 14:23 Rev Time 0.00
Received By rlecky Date 2010-12-28 Time 14:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-12-03 Cont ID  
Sent By rlecky Date 2010-12-03 Time 14:07 Rev Time 0.00
Received By rlecky Date 2010-12-03 Time 09:33 Sent To  
Notes
2010-12-03 14:09:081. LOCATE ELECTRICAL PANEL ON PLANS. ACCESS TO THE
 ELECTRICAL PANEL SHALL PROVIDE SAFE WORKING CLEARANCE
 PER NEC, 110-26.
 2. PROVIDE DETAILS REGARDING THE SIZE OF THE EXISTING
 ELECTRICAL SERVICE INCLUDING FEEDERS. NEC, ARTICLE 220
 3. PROVIDE AN ELECTRICAL PANEL SCHEDULE SHOWING THE
 SIZE OF WIRING AND OVER CURRENT PROTECTION FOR ALL
 BRANCH CIRCUITS. NEC, 210-7(C)
 R. LECKY, ELECTRICAL PLANS EXAMINER, WPB CONSTRUCTION
 SERVICES . PHONE 561-805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-12-29 Cont ID  
Sent By wjolin Date 2010-12-29 Time 10:46 Rev Time 0.00
Received By wjolin Date 2010-12-29 Time 10:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-12-08 Cont ID  
Sent By wjolin Date 2010-12-08 Time 10:12 Rev Time 0.00
Received By wjolin Date 2010-12-08 Time 10:02 Sent To  
Notes
2010-12-08 10:12:101801 SOUTH FLAGLER DRIVE, #602
 PERMIT #10110291
 REVIEW COMMENTS - FIRE
  
 ALL DEMOLITION WORK TO CONFORM TO THE REQUIREMENTS OF
 NFPA 241.
  
 PROVIDE INFORMATION ON THE DRAWING DESCRIBING HOW THE
 FIRE SPRINKLERS WILL BE AFFECTED BY THE LOWERING OF THE
 KITCHEN CEILING AND THE NEW WALL LOCATIONS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
 (561) 805-6730

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-12-29 Cont ID  
Sent By wjolin Date 2010-12-29 Time 10:46 Rev Time 0.00
Received By wjolin Date 2010-12-14 Time 11:39 Sent To  
Notes
2010-12-27 11:42:06INCOMING SENT TO B-13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-12-09 Cont ID  
Sent By shill Date 2010-12-08 Time 15:42 Rev Time 0.00
Received By shill Date 2010-11-10 Time 17:02 Sent To  
Notes
2010-11-10 17:02:21B13
  

Review Stop Z ZONING
Rev No 1 Status N Date 2010-11-15 Cont ID  
Sent By eschneid Date 2010-11-15 Time 15:20 Rev Time 0.25
Received By eschneid Date 2010-11-15 Time 15:20 Sent To  
Notes
2010-11-15 15:20:26WORK LESS THAN 50% VALUE OF UNIT.