| Plan Review Stops For Permit 10110288 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-01-14 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2011-01-14 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2011-01-14 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2011-01-14 12:01:28 | INITIAL PERMIT APPLICATION WAS SUBMITTED AS CONTRACTOR | | | "TBD". PREVIOUS REVIEW WAS DEEMED CODE COMPLIANT AND | | | JUST AWAITING A CONTRACTOR TO SUBMIT A PERMIT | | | APPLICATION FORM. A LICENSED CONTRACTOR HAS NOW | | | SUBMITTED A SIGNED PERMIT APPLICATION FORM FOR THIS | | | SCOPE OF WORK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-01-11 |
Time |
11:28 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2011-01-11 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2011-01-11 11:29:01 | PLANS ARE CODE COMPLIANT AND STAMPED , REQUIRES A | | | PROPERLY LICENSED CONTRACTOR TO BE SIGNED ON NEED TO | | | VERIFY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-11-23 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-11-23 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2010-11-23 08:46:32 | PLANS ARE CODE COMPLIANT AND STAMPED , REQUIRES A | | | PROPERLY LICENSED CONTRACTOR TO BE SIGNED ON NEED TO | | | VERIFY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-12-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-08 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2010-12-08 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2011-01-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-01-12 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-01-12 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2011-01-12 13:05:28 | 525 OKEECHOBEE BOULEVARD, SUITE #750 | | | PERMIT #10110288 | | | REVIEW COMMENTS - FIRE | | | | | | *****APPROVED WITH PROVISIOINS***** | | | | | | PROVIDE 90-MINUTE FIRE-RATED DOORS FOR OPENING | | | PROTECTION IN NEW 2-HOUR FIRE-RATED WALL ASSEMBLY. THE | | | DOORS AFFECTED ARE 701 AND 714. THE PROPOSED SPRINKLER | | | WATER CURTAIN AT THE MAIN ENTRY PROVIDES ONLY A 1-HOUR | | | SEPARATION EQUIVALENT AND IS ONLY APPLICABLE TO ATRIUM | | | GLAZING CURTAIN WALLS. TYCO MODEL WS WINDOW SPRINKLERS | | | ARE THE ONLY UL-LISTED SPRINKLERS THAT CAN PROVIDE AN | | | EQUIVALENT TWO-HOUR FIRE SEPARATION; HOWEVER,THESE | | | SPRINKLERS ARE ONLY LISTED TO PROTECT WINDOWS, NOT | | | DOORS. | | | | | | THE 2007 EDITION OF THE FLORIDA FIRE PREVENTION CODE | | | USES THE 2006 EDITION OF THE LIFE SAFETY CODE - NFPA | | | 101 WITH FLORIDA AMENDMENTS. THE COVER SHEET REFERENCES | | | THE 2003 EDITION OF NFPA 101. | | | | | | CONSTRUCTION DOCUMENTS ARE NEEDED FOR THE MODIFICATION | | | OF THE FIRE ALARM AND AUTOMATIC SPRINKLER SYSTEMS. | | | ADDITIONALLY, SEPARATE PLANS AND PERMITS WILL BE NEEDED | | | FOR THE FIRE ALARM AND SPRINKLER SYSTEM SHOP DRAWINGS. | | | | | | THE ACCESS-CONTROLLED EGRESS SYSTEM SHALL BE INTEGRATED | | | WITH THE BUILDING FIRE ALARM SYSTEM AND FIRE SPRINKLER | | | SYSTEM. | | | | | | PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2011-01-06 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-01-06 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-01-06 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2011-01-06 10:33:36 | 525 OKEECHOBEE BOULEVARD, SUITE #750 | | | PERMIT #10110288 | | | REVIEW COMMENTS - FIRE | | | | | | REPEAT COMMENT: THE 2007 EDITION OF THE FLORIDA FIRE | | | PREVENTION CODE USES THE 2006 EDITION OF THE LIFE | | | SAFETY CODE - NFPA 101 WITH FLORIDA AMENDMENTS. THE | | | COVER SHEET REFERENCES THE 2003 EDITION OF NFPA 101. | | | | | | REPEAT COMMENT: TO OBTAIN A BUILDING PERMIT, | | | CONSTRUCTION DOCUMENTS ARE NEEDED FOR THE MODIFICATION | | | OF THE FIRE ALARM AND AUTOMATIC SPRINKLER SYSTEMS. | | | ADDITIONALLY, SEPARATE PLANS AND PERMITS WILL BE NEEDED | | | FOR THE FIRE ALARM AND SPRINKLER SYSTEM SHOP DRAWINGS. | | | | | | REPEAT COMMENT: THE ACCESS-CONTROLLED EGRESS SYSTEM | | | SHALL BE INTEGRATED WITH THE BUILDING FIRE ALARM SYSTEM | | | AND FIRE SPRINKLER SYSTEM. | | | | | | NEW COMMENT: PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | NOTE: THE CURRENT EXIT ACCESS CONFIGURATION CREATES A | | | COMMON PATH OF TRAVEL GREATER THAN 100 FEET. THE TWO | | | DOORS (701 & 714) FROM THE TENANT SUITE ARE STILL | | | CONSIDERED EXIT ACCESS AND NOT EXIT. | | | | | | THE DESIGN TEAM HAS PROPOSED THE INSTALLATION OF A | | | TWO-HOUR FIRE-RATED WALL SEPARATION BETWEEN TENANT | | | SUITE #750 AND THE EXIT ACCESS CORRIDOR. THIS | | | ALTERNATIVE METHOD IS SUBMITTED AS A REQUEST FOR | | | EQUIVALENCY. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-11-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-11-30 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-11-30 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2010-11-30 17:04:14 | 525 OKEECHOBEE BOULEVARD, SUITE #750 | | | PERMIT #10110288 | | | REVIEW COMMENTS - FIRE | | | | | | THE 2007 EDITION OF THE FLORIDA FIRE PREVENTION CODE | | | USES THE 2006 EDITION OF THE LIFE SAFETY CODE - NFPA | | | 101 WITH FLORIDA AMENDMENTS. THE COVER SHEET REFERENCES | | | THE 2003 EDITION OF NFPA 101. | | | | | | THE CURRENT EXIT ACCESS CONFIGURATION CREATES A COMMON | | | PATH OF TRAVEL GREATER THAN 100 FEET. THE TWO DOORS | | | (701 & 714) FROM THE TENANT SUITE ARE STILL CONSIDERED | | | EXIT ACCESS AND NOT EXITS. OCCUPANTS EXITING THROUGH | | | DOOR 714 WILL CONVERGE WITH THE OCCUPANTS EXITING | | | THROUGH DOOR 701. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHER LOCATIONS ON THE | | | FLOOR PLAN. | | | | | | TO OBTAIN A BUILDING PERMIT, CONSTRUCTION DOCUMENTS ARE | | | NEEDED FOR THE MODIFICATION OF THE FIRE ALARM AND | | | AUTOMATIC SPRINKLER SYSTEMS. ADDITIONALLY, SEPARATE | | | PLANS AND PERMITS WILL BE NEEDED FOR THE FIRE ALARM AND | | | SPRINKLER SYSTEM SHOP DRAWINGS. | | | | | | THE COLUMNS AND FURNITURE LAYOUT CREATE AN AISLE THAT | | | IS LESS THAN 36 INCHES IN WIDTH ON SHEET A-1.1. | | | | | | THE ACCESS-CONTROLLED EGRESS SYSTEM SHALL BE INTEGRATED | | | WITH THE BUILDING FIRE ALARM AND FIRE SPRINKLER SYSTEM. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | (561) 805-6730 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-01-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-01-12 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-01-12 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-01-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-01-03 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-01-03 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-08 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2010-11-10 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-11-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-11-16 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-11-16 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-01-07 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-01-07 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-01-06 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-11-16 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-11-16 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-11-15 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2010-11-16 08:52:09 | FBC PLUMBING 2007 REVIEW #1 | | | DENIED: | | | | | | 1. AAV SHOWN IS NOT WITHIN THE TOP 4 FLOOR BRANCH | | | INTERVALS. | | | 917.3.1 LOCATION OF BRANCH. THE HORIZONTAL BRANCH DRAIN | | | SHALL CONNECT TO THE DRAINAGE STACK OR BUILDING DRAIN A | | | MAXIMUM OF FOUR BRANCH INTERVALS FROM THE TOP OF THE | | | STACK. | | | | | | 2. DISH WASHER WILL REQUIRE A SHOCK ARRESTOR. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-11-30 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-11-30 |
Time |
13:41 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2010-11-30 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2010-11-30 13:42:08 | INTERIOR ONLY |
|
|