| Plan Review Stops For Permit 10110283 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-22 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-22 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2010-12-22 15:42:30 | PROVISOS | | | | | | 1. GARAGE DOOR NOA SUBMITTED (09-0604.05), STEEL | | | SECTIONAL GARAGE DOOR, DOES NOT MATCH THE BROCHURE | | | SUBMITTED TO HISTORIC (BOB TIMBERLAKE WOOD CARRIAGE | | | DOOR). SEPARATE PERMIT REQUIRED FOR THE GARAGE DOOR. | | | THE GARAGE DOOR IS NOT INCLUDED IN THE SCOPE OF THIS | | | PERMIT. | | | | | | 2. SUBJECT TO FIELD INSPECTOR'S DISCRETION, A DETAIL | | | MAY BE REQUIRED FOR SIDING REPAIR (SUBMIT AS REVISION). | | | | | | 3. A MISCELLANEOUS INSPECTION IS REQUIRED PRIOR TO | | | SIDING REPAIR TO VERIFY SUBSTRATE CONDITION. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-12-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-09 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-09 |
Time |
09:33 |
Sent To |
E |
|
| Notes |
| 2010-12-09 13:24:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. VALUE IS TOO LOW. EITHER REVISE APPLICATION VALUE TO | | | INCLUDE THE FULL VALUE ($30,000 FOR IMPACT | | | WINDOWS/DOORS, $20,000 FOR ELECTRIC REWIRE, PLUS | | | ADDITIONAL AMOUNT FOR GARAGE DOOR AND SIDING REPAIRS). | | | ALTERNATIVELY, APPLY FOR THE FOLLOWING PERMITS: | | | | | | WINDOWS/DOORS, REISSUE PERMIT (WITH PARTIAL CREDIT FOR | | | EXPIRED PERMIT 07070245) | | | ELECTRIC, REISSUE PERMIT (WITH PARTIAL CREDIT FOR | | | 08020377) | | | GARAGE DOOR & SIDING REPAIRS, NEW PERMIT (INCLUDE FULL | | | VALUE) | | | | | | 2. REVISE EXPOSURE CATEGORY TO EXPOSURE C OR PROVIDE | | | CALCULATIONS FOR PRESSURES IN THE TRANSITION ZONE. | | | FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED | | | EFFECTIVE MARCH 1, 2009. | | | | | | 3. PRODUCT APPROVALS REQUIRED FOR ALL COMPONENTS & | | | CLADDING SUCH AS WINDOWS, DOORS, MULLIONS, FAC9B72. | | | | | | 4. PROVIDE A PLAN WHICH SHOWS LOCATION AND SCOPE OF THE | | | SIDING REPAIR. | | | | | | 5. PROVIDE A DETAIL FOR THE PROPOSED SIDING | | | REPLACEMENT. PRODUCT APPROVALS MAY BE REQUIRED, SEE | | | FAC9B72. | | | | | | 6. ADVISORY ONLY, AN INSPECTION WILL BE REQUIRED TO | | | VERIFY INTEGRITY OF SUBSTRATE PRIOR TO SIDING | | | INSTALLATION. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2010-12-10 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-10 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2010-12-10 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2010-12-10 09:27:48 | DISREGARD PREVIOUS APPROVAL, NO ELECTRICAL WORK | | | ASSOCIATED WITH THIS APPLICATION. | | | | | | L.MARTINEZ |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-12-10 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-10 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2010-12-10 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2010-12-10 09:04:06 | SEPERATE ELECTRICAL PERMIT REQUIRED. RL |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-12-14 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2010-12-14 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2010-12-14 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2010-12-13 16:56:20 | WINDOWS APPROVED ACCORDING ORIGINAL PERMIT #07070245. | | | | | | JILLIAN PAPA | | | HISTORIC PRESERVATION PLANNER | | | 561-822-1454 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-11-09 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2010-11-09 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2010-11-09 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2010-11-09 15:34:18 | ***FAILED*** | | | | | | 11/9/2010 | | | | | | 1. INSUFFIECIENT INFORMATION. NO PRODUCT INFORMATION | | | WAS SUBMITTED REGARDING THE GARAGE DOOR REPLACEMENT. | | | | | | JILLIAN PAPA | | | HISTORIC PRESERVATION PLANNER | | | 561-822-1454 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-22 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-13 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2010-12-13 13:57:41 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-10 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2010-12-10 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2010-11-12 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2010-11-12 15:43:16 | SENT TO MISC. BOX #1. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-11-09 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2010-11-09 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2010-11-09 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2010-11-09 15:38:38 | 11/9/2010 | | | | | | FURTHER ZONING REVIEW NOT REQUIRED. 50% OF APPRAISED | | | VALUE THRESHOLD NOT TRIGGERED BY SCOPE OF WORK. | | | | | | JILLIAN PAPA | | | HISTORIC PRESERVATION PLANNER | | | 561-822-1454 |
|
|