| Plan Review Stops For Permit 10110181 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-06-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-06-08 |
Time |
15:15 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2011-06-08 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-11-23 |
Time |
07:38 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-11-23 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2010-11-23 07:52:53 | BUILDING PLAN REVIEW | | | PERMIT: 10110181 | | | ADD: 1920 WEKIVA WAY | | | CONT: J CROMPTON ELECTRIC, INC. | | | TEL: (561)588-6559 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET T1 INDICATES THE WIND DESIGN CRITERIA AS A | | | NORMAL DESIGN 3 SECOND GUST WIND VELOCITY 140 MPH. THE | | | PLANS ARE LACKING THE WIND DESIGN CRITERIA AS TO: | | | | | | 1609.6.2 WIND DESIGN PROCEDURES | | | 1.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN | | | ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE | | | ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. | | | | | | 1.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN | | | ACCORDANCE WITH SECTION1609.5. | | | | | | 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4. PLEASE NOTE THIS IS A "C" | | | EXPOSURE. | | | | | | 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4) | | | | | | 1.5) DESIGNED AS OPEN, SEMI- ENCLOSED OR ENCLOSED. | | | | | | 1.6 PRESSURES FOR DOOR OPENINGS. | | | | | | 2) PLEASE PROVIDE THE LOCATION AND TYPE OF ANCHORS TO | | | BE INSTALLED TO COUNTER THE MOMENT OF OVERTURNING AND | | | SLIPPAGE, FBC-B 1604.4. | | | | | | 3) MISSING PRODUCT APPROVALS FOR DOOR OPENINGS, | | | REQUIRED BY RULE 9B-72. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-12-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-12-23 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-12-23 |
Time |
19:05 |
Sent To |
|
|
| Notes |
| 2010-12-24 19:23:28 | PLAN PASSED | | | | | | NEEDED BEFORE FIRST ROUGH INSPECTION | | | | | | DETAIL OF THE GROUNDING AT THE GENERATOR AND TRANSFER | | | SWITCH 250.32 B,D | | | | | | DETAIL OF THE GROUNDING AT THE EXISTING BUILDING 250.32 | | | B,D | | | | | | THIS IS NOT NEEDED FOR UNDERGROUND PIPE INSPECTIONS | | | | | | QUESTIONS 561-644-7291 JAKE LEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-05-27 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-05-27 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-05-27 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2011-05-27 12:45:38 | 1920 WEKIVA WAY | | | PERMIT #10110181 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****PROVISO***** | | | | | | PER NFPA 1 (FLORIDA EDITION) CHAPTER 66 SECTION | | | 66.2.3.2.3: MEANS TO CONTROL SPILLS FROM ABOVEGROUND | | | STORAGE TANKS SHALL BE PROVIDED IN ACCORDANCE NFPA 30. | | | SUBMIT INFORMATION DETAILING HOW SPILL CONTROL WILL BE | | | ACHIEVED. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-11-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-11-17 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-11-17 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2010-11-17 10:49:50 | 1920 WEKIVA WAY | | | PERMIT NUMBER 10110181 | | | GENERATOR INSTALLATION | | | | | | 1. ALL ELECTRICAL WORK TO COMPLY WITH NFPA 70, THE | | | NATIONAL ELECTRICAL CODE. | | | | | | 2. ENTIRE GENERATOR INSTALLATION TO COMPLY WITH NFPA | | | 110. | | | | | | 3. PLANS DO NOT CONTAIN ANY STAMPS FROM THE DEPARTMENT | | | OF ENVIRONMENTAL RESOURCE MANAGEMENT (DERM). | | | | | | 4. PLEASE PROVIDE AN APPROVED SURVEY OF THE PROPOSED | | | PROPERTY WHERE THE GENERATOR IS TO BE INSTALLED. | | | | | | 5. APPROPRIATE SIGNAGE IS REQUIRED TO BE ON THE PLANS. | | | THIS SIGNAGE SHALL INCLUDE THE NFPA 704 DIAMONDS, "NO | | | SMOKING" SIGNS, PRODUCT NAME AND QUANTITY OF THE DIESEL | | | FUEL. | | | | | | 6. PLEASE INDICATE ON THE PLANS WHAT EQUIPMENT THE | | | GENERATOR IS EXPECTED TO RUN. IS IT LIFE SAFETY | | | EQUIPMENT ONLY OR GENERAL LOADS OR BOTH AND PLEASE | | | INDICATE DURATION. | | | | | | DENIED | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION | | | | | | | | | |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
P |
Date |
2011-06-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-06-21 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-06-21 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2011-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-05-17 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2011-05-20 13:36:34 | 5/19/11 SUBMITTAL FOR IRRAGATION AND LANDSCAPING. | | 2011-05-17 12:30:58 | C14 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-12-23 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-11-05 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
N |
Date |
2011-05-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2011-05-20 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2011-05-20 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2011-05-20 16:05:52 | ***LANDSCAPE NOT REQUIRED*** | | | | | | PLEASE REFER TO PERMIT #11050583 FOR LANDSCAPE PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2010-12-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-12-20 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-12-20 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2010-12-20 16:46:53 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT. | | | | | | 1. PLEASE APPLY FOR A SEPARATE LANDSCAPE PERMIT FOR THE | | | REQUIRED LANDSCAPING FOR THIS PROJECT. TWO (2) COPIES | | | OF A LANDSCAPE PLAN WILL BE REQUIRED WITH THE | | | APPLICATION. | | | | | | 2. AN IRRIGATION PERMIT WILL BE REQUIRED. | | | | | | 3 PURSUANT TO SECTION 94-444 (B), WALLS INSTALLED FOR | | | SCREENING OF EQUIPMENT SHALL BE LANDSCAPED WITH SHRUBS | | | AND HEDGES PLANTED AT TWO-FOOT INTERVALS. BECAUSE THIS | | | WALL WILL BE NINE (9) FEET IN HEIGHT, THE PLANT | | | MATERIAL SHALL BE TALL ENOUGH AT PLANTING TO ADEQUATELY | | | SCREEN THE WALL. IF THE PLANT MATERIAL IS LARGER, THE | | | SPACING BETWEEN PLANTS CAN BE EXPANDED BEYOND THE 24 | | | INCHES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-06-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-06-21 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-06-21 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-11-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-11-16 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-11-16 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2010-11-16 12:17:52 | PLANS MUST BE SUBMITTED TO DERM. | | | PLANREVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-06-08 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-06-08 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2011-06-08 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2011-06-08 18:48:30 | PLANNING AND ZONING: ***** PASSED WITH PROVISO: COMPLY | | | WITH LANDSCAPING PERMIT COMMENTS PRIOR TO FINAL | | | APPROVAL BY ZONING. **** | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-12-21 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-12-10 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-12-10 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2010-12-10 13:53:13 | PLANNING AND ZONING: ***** FAILED**** | | | | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. A MINOR AMENDMENT TO THE INFORMAL SITE PLAN REVIEW | | | APPROVAL ("ISPR 05-09") IS REQUIRED. AN APPLICATION | | | WILL NEED TO BE FILED TO THE PLANNING AND ZONING | | | DEPARTMENT AND APPROVED PRIOR TO SIGN-OFF OF BUILDING | | | PERMIT. YOU CAN DOWNLOAD AN APPLICATION AT THE LINK | | | BELOW: | | | | | | HTTP://WWW.WPB.ORG/PLAN/INDEX.PHP?PAGE=PB, SCROLL TO | | | THE MIDDLE OF THE PAGE AND DOWNLOAD THE DEVELOPMENT | | | APPLICATION (SEE PAGE 2, SITE PLAN AMENDMENT (MINOR - | | | LEVEL 1) FOR APPLICATION REQUIREMENTS. | | | | | | THE COMMENTS BELOW REFLECT THE INFORMATION NEEDED ON | | | SITE PLAN, PRIOR TO SUBMITTAL OF THE MINOR AMENDMENT TO | | | THE ISPR 05-09. | | | | | | 3. ON SHEET C4, "GENERATOR COMPOUND CROSS SECTION," | | | INCLUDE THE GENERATOR PROFILE WITHIN THE ENCLOSURE TO | | | ASSURE THAT THE ENTIRE GENERATOR WILL BE SCREENED. ALSO | | | SHOW DETAIL OF LANDSCAPING AND CURBING WITH THE CROSS | | | SECTION. | | | | | | THE SITE PLAN SHALL INCLUDE THE FOLLOWING: | | | | | | A. SCREENING AND ELEVATION OF WALL/HEDGES AROUND | | | GENERATOR/ FUEL TANK, AND SETBACK DISTANCE FROM | | | PROPERTY LINES. | | | | | | B. SHOW AMENDED SITE DATA TABLE THAT DEPICTS THE TOTAL | | | PARKING SPACES THAT WERE REQUIRED/PROVIDED AND INCLUDE | | | THE DELETION (MINUS) OF THE PARKING SPACES THAT WILL BE | | | TAKEN UP BY THE NEW GENERATOR. A TERMINAL LANDSCAPE | | | ISLAND WILL BE REQUIRED ON BOTH SIDES OF THE GENERATOR | | | ENCLOSURE, SO ADDITIONAL PARKING WILL BE TAKEN UP. | | | THERE SEEMS TO BE EXCESS PARKING FROM THE APPROVED | | | PLANS, BUT THE REVISIONS SHOWING WHAT WAS REQUIRED AND | | | PROVIDED NEED TO ALSO BE SHOWN. A COPY OF THE APPROVED | | | PLANS CAN BE PROVIDED AT YOUR REQUEST FOR REFERENCE. | | | | | | NOTE: IS IT POSSIBLE TO MOVE THE GENERATOR OUT OF THE | | | GENERAL PARKING AREA TO A MORE CONSPICUOUS AREA SUCH AS | | | THE SOUTHEASTERN CORNER OF THE PROPERTY (WHERE THERE | | | ARE SIX (6) PARKING SPACES)? THERE ARE TWO EXISTING | | | LANDSCAPE TERMINAL ISLANDS IN PLACE THAT CAN | | | ACCOMMODATE THE PROPOSED GENERATOR WITH LESS | | | CURBING/LANDSCAPING ISLANDS REQUIRED. | | | | | | 4. PURSUANT TO SECTION 94-444(B) OPEN SPACE | | | STANDARDS: | | | | | | (B) FUEL OR OIL OR PROPANE TANKS, GENERATORS SHALL NOT | | | BE PERMITTED UNLESS APPROPRIATE SCREENING IS PROVIDED. | | | SCREENING SHALL BE CONSTRUCTED OF BRICK, DECORATIVE | | | CONCRETE, OTHER | | | DECORATIVE MASONRY, OR COMPARABLY, DURABLE WOOD AND | | | STEEL. | | | | | | WALLS SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES | | | PLANTED AT TWO-FOOT INTERVALS. A FOUR-SIDED ENCLOSURE | | | WITH MASONRY, OR COMPARABLY DURABLE WOOD AND STEEL, AN | | | OBSCURING GATE IS REQUIRED AS A CONDITION FOR SITE PLAN | | | APPROVAL. | | | | | | THE SCREENING SHALL ENCLOSE BOTH FUEL TANK AND ROOFTOP | | | EXHAUST. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | | | | |
|
|