Plan Review Details - Permit 10100734
| Plan Review Stops For Permit 10100734 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-01-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-28 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-28 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2011-01-28 14:02:21 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SHOW ACCESSIBLE ROUTE FROM THE ACCESSIBLE PARKING | | | SPACE(S) TO THE ACCESSIBLE ENTRANCE(S), FBC11-4.6.2(1). | | | SHOW SIDEWALK WIDTH (44" MINIMUM). | | | | | | 2. SHOW ACCESSIBLE ROUTE FROM THE PUBLIC WAY WHICH | | | CONNECTS ACCESSIBLE ELEMENTS, FBC11-4.1.3(1). | | | | | | 3. ONE ACCESSIBLE PARKING SPACE LACKS AN ACCESS AISLE, | | | SEE FBC 11-4.6.2. NOTE THAT FOUR ACCESSIBLE SPACES ARE | | | REQUIRED FOR 85 SPACES, FIVE ARE SHOWN. IT IS | | | ACCEPTABLE TO EXCEED CODE COMPLIANCE, HOWEVER, IF | | | ADDITIONAL ACCESSIBLE SPACES ARE PROVIDED, THEY MUST | | | COMPLY WITH ALL REQUIREMENTS. | | | | | | 4. HOW IS THE SIDEWALK ACCESSED? NO RAMP SHOWN. | | | | | | 5. HAVE THE DESIGNER LICENSED TO DESIGN AND TAKE | | | RESPONSIBILITY FOR THIS SCOPE OF WORK PROVIDE HIS OR | | | HER PRINTED NAME, LICENSE NUMBER, SEAL (IF APPLICABLE) | | | AND SIGNATURE ON THE PLAN, FS471, 481, 489. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2011-01-03 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2011-01-03 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2011-01-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2011-01-03 10:16:52 | PLEASE RESPOND TO PREVIOUS COMMENTS IN WRITING. | | | | | | MANUEL JULIAN GONZALEZ | | | CSD ENGINEERING REVIEW | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2010-11-08 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2010-11-08 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2010-11-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2010-11-08 15:38:31 | NOT PASSED: | | | | | | 1. PROVIDE PARKING SURFACE CALCULATIONS. PERVIOUS / | | | IMPERVOUS / TOTAL SITE IN S.F. / AC. | | | | | | 2. APPLICANT SHALL PROVIDE A WRITTEN SUMMARY PROVIDING | | | REASONABLE ASSURANCES THAT THE SURFACE WATER MANAGEMENT | | | SYSTEM WILL NOT CAUSE ADVERSE WATER QUALITY AND | | | QUANTITY IMPACTS ON RECEIVING WATER AND ADJACENT LANDS | | | REGULATED PURSUANT TO CHAPTER 373, F.S. | | | CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA, | | | CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22, | | | 2008. (SUPPLEMENT NO. 18), CHAPTER 90 UTILITIES, | | | ARTICLE V. STORMWATER POLLUTION PREVENTION | | | SEC. 90-203. PROHIBITED DISCHARGES; ILLICIT | | | CONNECTIONS. | | | (A) GENERAL PROHIBITION. EXCEPT AS PROVIDED IN SECTION | | | 90-205, AND EXCEPT PURSUANT TO A VALID NPDES | | | PERMIT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE, SPILL, OR | | | DUMP INTO | | | ANY OF THE PUBLIC WATERS OR MUNICIPAL SEPARATE STORM | | | SEWER SYSTEM WITHIN THE CITY, ANY SUBSTANCE OTHER | | | THAN THAT COMPOSED ENTIRELY OF STORMWATER. | | | | | | 3. FBC, SECTION 11-4.29.5. (DETECTABLE WARNINGS) | | | TRUNCATED DOMES REQUIRED ON TWO WAY TRAFFIC | | | INGRESS/EGRESS AREAS. | | | | | | MANUEL JULIAN GONZALEZ | | | CSD ENGINEERING REVIEW | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-12-16 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-12-16 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2011-01-10 10:09:56 | 1/10 TO MISC 3 | | 2010-12-16 17:36:38 | IN ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-11-08 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-10-28 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2010-10-28 16:35:45 | IN ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2010-12-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-12-27 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2010-12-27 |
Time |
13:59 |
Sent To |
ENG |
|
| Notes |
| 2010-12-27 14:56:22 | FAILED | | | | | | 1) THE SCOPE OF WORK WAS CHANGED TO SEAL COATING THE | | | PARKING LOT WITH THE RE-STRIPE TO MATCH EXISTING. THE | | | PARKING LAYOUT PLAN SHOWS THE LANDSCAPE AT THE ENTRANCE | | | OF THE BUILDING (NORTHEAST SIDE) BEING REMOVED AND | | | REPLACED WITH THREE (3) HANDICAP PARKING SPACES. THIS | | | MAY NOT BE ACCOMPLISHED AS PART OF A SEAL COATING | | | PERMIT. IF IT IS TO BE DONE, IT WILL REQUIRE LANDSCAPE | | | UPGRADES TO THE SITE AND A DEMOLITION PERMITTING TO | | | REMOVE THE CURBING. NEW PLAN DOES NOT MATCH PREVIOUSLY | | | APPROVED PLAN OR THE 2009 AERIAL OF THE SITE. | | | | | | 2) THE PARKING LAYOUT PLAN SHOWS THE LANDSCAPE ISLAND | | | AT THE ENTRANCE TO THE SITE, ADJACENT TO THE FIRST | | | NON-HANDICAP PARKING SPACE, IN A DIFFERENT | | | CONFIGURATION THAN THE EXISTING ENTRANCE CONDITION. THE | | | PROPOSED PLAN SHOWS THE LANDSCAPE AREA ENLARGED WHICH | | | WOULD REQUIRE THE DEMOLITION AND ADDITION OF CURBING | | | AND THE ADDITION OF SODDED AREA. SITE PERMITTING IS | | | REQUIRED FOR THIS WORK. NEW PLAN DOES NOT MATCH | | | PREVIOUSLY APPROVED PLAN OR THE 2009 AERIAL OF THE | | | SITE. | | | | | | 3) THERE IS A DISCREPANCY WITH PREVIOUSLY APPROVED PLAN | | | AND THE CONFIGURATION OF THE END OF THE PARKING ROW | | | ALONG THE SOUTHWESTERN PROPERTY LINE ADJACENT TO THE | | | PARKING SPACE CLOSEST TO THE BUILDING. THE PROPOSED | | | PLAN SHOWS AN ISLAND, THE EXISTING PLAN DOES NOT. THE | | | SEAL COAT PERMIT AS SUBMITTED WILL NOT COVER THIS WORK. | | | | | | 4) DUE TO THE SUBMITTED PLANS SHOWING INACCURATE | | | INFORMATION AND NOT MATCHING EXISTING CONDITIONS (2009 | | | AERIAL) OR PREVIOUSLY APPROVED PLANS FOR THE SECOND | | | SUBMITTAL, A SURVEY OF THE SITE, LESS THAN ONE YEAR | | | OLD, SHALL BE PROVIDED WITH THE NEXT SUBMITTAL. ALL | | | PLANS SHALL BE BASED UPON THE DIMENSIONS AND | | | CONFIGURATION SHOWN ON THE SURVEY. | | | | | | 5) REPEAT COMMENT - THE CITY REQUIRES PARKING SPACES TO | | | BE DOUBLE STRIPED AND WHEEL STOPS TO BE LOCATED TWO (2) | | | FEET FROM THE END OF THE PARKING SPACE.. THE CITY'S | | | STANDARD PARKING DETAIL SHALL BE INCLUDED ON THE | | | RESUBMITTAL. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-11-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-11-05 |
Time |
16:16 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2010-10-29 |
Time |
10:51 |
Sent To |
ENG |
|
| Notes |
| 2010-11-05 16:30:40 | FAILED | | | | | | 1) THE PERMIT IS TO RE-PAVE THE PARKING LOT. THE CITY | | | CONSIDERS RE-PAVING OF A PARKING LOT AS A NEW PARKING | | | LOT. IF THE PARKING DOES NOT MEET CURRENT CODES, THEN | | | THE PARKING SHALL BE BROUGHT INTO CONFORMITY WITH THE | | | CURRENT PARKING REGULATIONS, INCLUDING THE INSTALLATION | | | OF INTERIOR AND PERIMETER LANDSCAPE. THE PARKING LOT | | | DOES NOT CONFORM TO ARTICLES XIV AND XV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS. | | | | | | 2) THE SUBMITTED PLANS DO NOT MATCH THE ON-SITE | | | CONDITIONS. IS THE PERMIT INTENDED TO RE-STRIPE THE | | | PARKING LOT ACCORDING TO THE SUBMITTED PLANS OR THE | | | EXISTING CONDITIONS? | | | | | | 3) THE SUBMITTED PLANS ARE ILLEGIBLE FOR PLACEMENT OF | | | THE HANDICAP PARKING SPACES. THE PLANS NEED TO CLEARLY | | | SHOW DIMENSIONS OF THE HANDICAP PARKING SPACES AND | | | ACCESS AISLES. | | | | | | 4) SOME OF THE DIMENSIONS ARE INCORRECTLY CALLED OUT ON | | | THE PLANS. | | | | | | 5) PROVIDE PARKING DETAILS MEETING CITY OF WEST PALM | | | BEACH STANDARDS FOR ALL OF THE VARIOUS PARKING ANGLES. | | | THESE SHALL INCLUDE DIMENSIONS AND STRIPING | | | SPECIFICATIONS AND CORRECT WHEEL STOP PLACEMENT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |