Plan Review Details - Permit 10100654
| Plan Review Stops For Permit 10100654 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-24 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-24 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-11-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-09 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-09 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2010-11-09 10:28:19 | ****PROVISO**** | | | ****REVISION REQUIRED**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PER ARCHITECT, CASEMENT WINDOWS WILL BE INSTALLED IN | | | LOCATIONS MARKED "EGRESS". REVISE WINDOW SCHEDULE. | | | | | | 2. REVISE PLAN TO SHOW BOND BREAK FOR STUCCO, FBC | | | R703.6.3, DETAILS 2 AND 3 A3.1. | | | | | | 3. DETAILS 2 AND 3, SHEET A3.1, 4D NAILS SPECIFIED FOR | | | LATH ATTACHMENT. SEE FBC R703.6.2, A MINIMUM OF 1 3/4" | | | PENETRATION REQUIRED INTO STRUCTURAL MEMBER PER ASTM | | | C1063. PLEASE REVISE ALL AFFECTED DETAILS. | | | | | | 4. S1.1, OUTDATED ASCE7 REFERENCE, FBC R 43, PLEASE | | | REVISE. | | | | | | 5. PRODUCT APPROVAL 05-0311.01 (AWP SERIES 1700), FL474 | | | (SIMPSON CONNECTORS) AND FL 3341 (FLEMING DOOR) ARE | | | EXPIRED AND HAVE BEEN REMOVED. SUBMIT CURRENT PRODUCT | | | APPROVALS WITH THE REVISION AS NECESSARY. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-11-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-04 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-04 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2010-11-04 09:18:55 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. ONLY ONE COMPLETE SET OF PLANS SUBMITTED. UPON | | | ISSUANCE, CONTRACTOR IS TO REQUEST INSPECTION SETS FROM | | | CSD RECORDS. | | | | | | 2. ARCHITECT'S RESPONSE LETTER STATES THAT CASEMENT | | | WINDOWS WILL BE INSTALLED, BUT PLANS SHOW ONLY SINGLE | | | HUNG. SEE FBC EXISTING BUILDING 604.1 REGARDING WINDOW | | | REPLACEMENT, BEDROOM EGRESS REQUIREMENTS AND EXCEPTION. | | | | | | 3. BOND BREAK REQUIRED, FBC R703.6.3, DETAILS 2 AND 3 | | | A3.1. PLANS WERE REVISED TO SHOW 30# PAPER OVER | | | SHEATHING, BUT ONE LAYER OF 30# OVER PLYWOOD DOES NOT | | | COMPLY WITH THE BOND BREAK REQUIREMENT. PLEASE REVISE | | | AND CHECK ALL DETAILS. | | | | | | 4. DETAILS 2 AND 3, SHEET A3.1, 4D NAILS SPECIFIED FOR | | | LATH ATTACHMENT. SEE FBC R703.6.2, A MINIMUM OF 1 3/4" | | | PENETRATION REQUIRED INTO STRUCTURAL MEMBER PER ASTM | | | C1063. PLEASE REVISE AND CHECK ALL DETAILS. | | | | | | 5. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | DOORS, WINDOWS, AND MULLIONS FAC9B72. | | | TRANSMITTAL/RESPONSE LETTER MAKES REFERENCE TO VARIOUS | | | PRODUCT APPROVALS BUT THE PRODUCT APPROVALS WERE NOT | | | SUBMITTED. | | | | | | 6. S1.1, OUTDATED ASCE7 REFERENCE, FBC R 43, PLEASE | | | REVISE. | | | | | | 7. ISSUANCE WITH PROVISO CAN BE CONSIDERED UPON | | | ARCHITECT'S REQUEST. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-18 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-18 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2011-01-18 08:56:40 | ELECTRICAL PROVISO | | | | | | 1) FBC R313.2.1 SMOKE ALARMS SHALL COMPLY WITH CURRENT | | | CODE. | | | | | | 2) NEC 406.11 TAMPER-RESISTANT RECEPTACLES TYPICAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-11-02 |
|
|
Cont ID |
|
| Sent By |
jdickins |
Date |
2010-11-02 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
jdickins |
Date |
2010-11-02 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2010-11-02 18:46:06 | OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE | | | NUMBER PX3182 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-01-24 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-01-14 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2011-01-18 07:22:18 | 1/18 TO RM DESK | | | | | 2011-01-14 11:24:18 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-11-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-04 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-28 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2010-10-28 11:04:37 | TO ELECTRIC | | | | | | |
|
|
|