Plan Review Details - Permit 10100397
| Plan Review Stops For Permit 10100397 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2010-11-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-19 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-19 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2010-11-19 14:49:58 | CHANGED SCOPE OF WORK TO REROOF ONLY (ADDITION PORTION | | | NOT INCLUDED UNTIL ENGINEER ADDRESSES COMMENT) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2010-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-15 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-15 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2010-11-15 13:41:53 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. ADDRESSED. | | | | | | 2. SEE BUILDING PROVISO #2, FAC9B72, PRODUCT APPROVALS | | | REVIEWED BY DESIGNER OF RECORD REQUIRED FOR ALL | | | COMPONENTS AND CLADDING. PLEASE HAVE THE ROOF PRODUCT | | | APPROVALS REVIEWED PRIOR TO SUBMISSION. | | | | | | 2ND REVIEW, PLEASE HAVE DESIGNER OF RECORD REVIEW | | | PRODUCT APPROVAL. | | | | | | 3. PRIOR TO INSTALLATION, INVESTIGATE AND ADDRESS ANY | | | POTENTIAL ISSUES WHICH MAY ARISE FROM DISSIMILAR METALS | | | ON THE ROOF (METAL ROOF, COPPER FLASHING, ALUMINUM | | | GUTTERS), R904.2. | | | | | | 4. BUILDING PROVISO #6, ENGINEER TO PROVIDE A LETTER OR | | | REVISE THE PLAN TO CONFIRM THAT THE DESIGN CONFORMS TO | | | THE REQUIREMENT OF FBC R301.2.1.4.3(2), "ROOF SHEATHING | | | UPLIFT AND ROOF-TO-WALL UPLIFT LOADS SHALL BE INCREASED | | | BY 20 PERCENT." PLEASE NOTE THAT SOME OF THE UPLIFT | | | ANCHORS DO NOT APPEAR TO BE INCREASED ON THE PLAN | | | SUBMITTED. THIS ITEM MUST BE ADDRESSED PRIOR TO | | | INSTALLATION OF ROOF FRAMING COMPONENTS AND PRIOR TO | | | ISSUANCE OF ROOF PERMIT. | | | | | | 5. UNDERLAYMENT PRODUCT APPROVAL SUBMITTED DOES NOT | | | INCLUDE THE INSTALLATION INSTRUCTIONS/EVALUATION | | | REPORT, FAC9B72. | | | | | | 6. ADDRESSED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-08 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-08 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2010-11-08 10:14:04 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THE METAL ROOF PRODUCT SUBMITTED HAS A DESIGN | | | PRESSURE LIMITATION OF -30PSF. SEE SHEET S-5, -56.5 | | | REQUIRED FOR ZONE 3, -48.4 REQUIRED FOR ZONE 2. | | | | | | 2. SEE BUILDING PROVISO #2, FAC9B72, PRODUCT APPROVALS | | | REVIEWED BY DESIGNER OF RECORD REQUIRED FOR ALL | | | COMPONENTS AND CLADDING. PLEASE HAVE THE ROOF PRODUCT | | | APPROVALS REVIEWED PRIOR TO SUBMISSION. | | | | | | 3. PRIOR TO INSTALLATION, INVESTIGATE AND ADDRESS ANY | | | POTENTIAL ISSUES WHICH MAY ARISE FROM DISSIMILAR METALS | | | ON THE ROOF (METAL ROOF, COPPER FLASHING, ALUMINUM | | | GUTTERS), R904.2. | | | | | | 4. BUILDING PROVISO #6, ENGINEER TO PROVIDE A LETTER OR | | | REVISE THE PLAN TO CONFIRM THAT THE DESIGN CONFORMS TO | | | THE REQUIREMENT OF FBC R301.2.1.4.3(2), "ROOF SHEATHING | | | UPLIFT AND ROOF-TO-WALL UPLIFT LOADS SHALL BE INCREASED | | | BY 20 PERCENT." PLEASE NOTE THAT SOME OF THE UPLIFT | | | ANCHORS DO NOT APPEAR TO BE INCREASED ON THE PLAN | | | SUBMITTED. THIS ITEM MUST BE ADDRESSED PRIOR TO | | | INSTALLATION OF ROOF FRAMING COMPONENTS AND PRIOR TO | | | ISSUANCE OF ROOF PERMIT. | | | | | | 5. UNDERLAYMENT PRODUCT APPROVAL SUBMITTED DOES NOT | | | INCLUDE THE INSTALLATION INSTRUCTIONS/EVALUATION | | | REPORT, FAC9B72. | | | | | | 6. THE ROOF METAL PRODUCT APPROVAL PROVIDED IS | | | "VALIDATED," SHOULD BE "APPROVED." PLEASE PROVIDE | | | CURRENT COVER SHEETS FOR ANY FLORIDA STATE PRODUCT | | | APPROVALS SUBMITTED, FAC9B72, WWW.FLORIDABUILDING.ORG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-11-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-11-10 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2010-11-12 09:38:03 | TO S HILL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-08 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-19 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2010-10-19 08:33:30 | SENT TO S. HILL'S DESK. |
|
|
|