Plan Review Details - Permit 10100341
Plan Review Stops For Permit 10100341
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-10-26 Cont ID  
Sent By jwitmer Date 2010-10-26 Time 10:40 Rev Time 0.55
Received By jwitmer Date 2010-10-26 Time 10:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-10-19 Cont ID  
Sent By shill Date 2010-10-19 Time 18:34 Rev Time 0.00
Received By shill Date 2010-10-19 Time 18:34 Sent To  
Notes
2010-10-19 18:36:22OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER PX3182

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-10-22 Cont ID  
Sent By mcarsill Date 2010-10-22 Time 13:04 Rev Time 0.00
Received By mcarsill Date 2010-10-22 Time 12:56 Sent To  
Notes
2010-10-22 13:04:381525 NORTH FLAGLER DRIVE
 PERMIT NUMBER 10100341
 "INTERIOR IMPROVEMENT"
  
  
 1. WRONG TELEPHONE NUMBER LISTED IN THE AUTHORITIES
 HAVING JURISDICTION BOX. THE TELEPHONE NUMBER FOR THE
 INSPECTIONS DEPARTMENT OF THE FIRE DEPARTMENT IS
 804-4724.(T1.0)
  
 2. WRONG LIFE SAFETY CODE REFERENCED. IT SHOULD READ
 2006 EDITION NOT THE 2003 EDITION. (T1.0)
  
 3. NFPA 72 IS THE NATIONAL FIRE ALARM CODE NOT THE
 UNIFORM FIRE CODE. (T1.0)
  
 4. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS.
  
  
 APPROVED PROVISO
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-11-01 Cont ID  
Sent By hmoser Date 2010-11-01 Time 13:59 Rev Time 0.00
Received By hmoser Date 2010-10-18 Time 13:49 Sent To  
Notes
2010-10-18 13:49:14B-13

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-11-01 Cont ID  
Sent By hmoser Date 2010-11-01 Time 13:57 Rev Time 0.00
Received By hmoser Date 2010-11-01 Time 13:31 Sent To  
Notes
2010-11-01 13:59:32REFER TO SECTION 606.3 FMC 2007 INSTALLATION.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-10-22 Cont ID  
Sent By lwagner Date 2010-10-22 Time 15:50 Rev Time 0.00
Received By lwagner Date 2010-10-22 Time 14:43 Sent To  
Notes
2010-10-22 15:15:03SEPARATE MED GAS PERMIT REQUIRED
  
 *****PROVISO*****
  
 713.7 CENTRAL VACUUM OR DISPOSAL SYSTEMS. WHERE THE
 WASTE
 FROM A CENTRAL VACUUM (FLUID SUCTION) SYSTEM OF THE
 BAROMETRIC-LAG,
 COLLECTION-TANK OR BOTTLE-DISPOSAL TYPE IS CONNECTED TO
 THE
 DRAINAGE SYSTEM, THE WASTE SHALL BE DIRECTLY CONNECTED
 TO THE
 SANITARY DRAINAGE SYSTEM THROUGH A TRAPPED WASTE.
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2010-11-02 Cont ID  
Sent By lfranco Date 2010-11-02 Time 18:06 Rev Time 0.00
Received By lfranco Date 2010-11-02 Time 18:06 Sent To  
Notes
2010-11-02 18:08:14PLANNING AND ZONING: *** *ZONING REVIEW NOT REQUIRED:
 INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES
 NOT EXCEED 50% OF THE IMPROVEMENT VALUE. ****
  
  