Plan Review Details - Permit 10100238
Plan Review Stops For Permit 10100238
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-11-12 Cont ID  
Sent By jgomez Date 2010-11-12 Time 13:30 Rev Time 0.00
Received By jgomez Date 2010-11-12 Time 12:58 Sent To PC
Notes
2010-11-12 13:41:36BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- FLORIDA PRODUCT APPROVAL FL4904-R3 SUBMITTED IS
 MISSING THE DRAWINGS FOR THE DOOR TO BE INSTALLED.
 PROVIDE THE DRAWINGS SHOWING THE SELECTED DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-10-20 Cont ID  
Sent By jgomez Date 2010-10-20 Time 15:50 Rev Time 0.00
Received By jgomez Date 2010-10-20 Time 15:48 Sent To  
Notes
2010-10-20 16:02:04RESIDENTIAL (R3) ADDITION/RENOVATION, BUILDING REVIEW
 CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- CONTRACTOR'S LICENSE U-18134 SHOWN ON THE PERMIT
 APPLICATION IS FOR ROOFING CONTRACTOR. NEED TO PROVIDE
 CURRENT GENERAL/BUILDING OR RESIDENTIAL CONTRACTOR
 LICENSE TO DO THE WORK .
  
 2- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) GARAGE AND UTILITY ROOM EXTERIOR SWING DOORS.
 DRAWINGS SUBMITTED ARE FOR 8'-0" HIGH DOORS. NEED TO
 PROVIDE DRAWINGS FOR 6'-8" HIGH DOORS. SEE PLANS.
  
 B) ENTRY DOOR AS SHOWN ON PLANS.
  
 C) SLIDING GLASS DOORS WITH SIZE OF DOORS SPECIFIED ON
 PLANS.
  
 D) SINGLE HUNG IMPACT WINDOWS. IF USING IMPACT WINDOWS.
 PERMIT APPLICATION CALLS FOR IMPACT WINDOWS. PRODUCT
 APPROVAL SUBMITTED IS FOR NON IMPACT WINDOWS.
  
 E) STORM SHUTTERS IF NOT ISSUING IMPACT WINDOWS. AND
 PROVIDE COMPLETE INSTALLATION SCHEDULE.
 ***NOTE: SHUTERS INSTALLATION REQUIRES HISTORIC
 APPROVAL BEFORE SUBMITTING TO THIS OFFICE.
  
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 4- DOOR LEADING TO THE KITCHEN FROM THE GARAGE NEEDS TO
 BE FIRE RATED AS REQUIRED BY SEC. R309.1 OF 2007
 FLORIDA RESIDENTIAL CODE. PROVIDE SPECIFICATIONS ON
 PLANS FOR TYPE OF DOOR TO BE INSTALLED.
  
 5- NEED TO SPECIFY CARBON MONOXIDE ALARMS ON PLANS AS
 REQUIRED BY SEC. R313.4 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-10-28 Cont ID  
Sent By jdickins Date 2010-10-28 Time 20:08 Rev Time 0.00
Received By jdickins Date 2010-10-28 Time 20:08 Sent To  
Notes
2010-10-28 20:21:22***APPROVED WITH THE FOLLOWING PROVISOS****
 1. ALL BRANCH CIRCUITS MUST BE PROTECTED WITH ARC FAULT
 PROTECTION PURSUANT TO ARTICLE 210-12 (B)
 2. BOTH SMOKE AND CARBON MONOXIDE DETECTION SHALL BE
 PROVIDED. HARD WIRED BATTERY BACKUP COMBINATION UNITS
 MAY BE UTILIZED WITHIN 10 FEET OF ALL SLEEPING ROOMS
 PURSUANT TO FBC-R AND NFPA-72.
 3. TAMPER RESISTANT RECEPTACLES ARE REQUIRED PURSUANT
 TO ARTICLE 406.11
 4. GFI PROTECTED WEATHER RESISTANT RECEPTACLES ARE
 REQUIRED OUTSIDE THE STRUCTURE AT BOTH THE FRONT AND
 REAR PURSUANT TO ARTICLE 210-52(E)(1)

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2010-10-12 Cont ID  
Sent By jpapa Date 2010-10-12 Time   Rev Time 0.00
Received By jpapa Date 2010-10-12 Time 16:26 Sent To  
Notes
2010-10-12 16:27:30*****PROVISOS*********
  
 1. THE PROPOSED WINDOWS AND DOORS SHALL HAVE WHITE
 FRAME AND CLEAR GLAZING (NO ADDITIONAL TINT).
 2. SECURITY BARS SHALL NOT BE INSTALLED ON WINDOW AND
 DOOR OPENINGS.
  
  
 JILLIAN PAPA
 HISTORIC PRESERVATION PLANNER
 561-822-1454

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-11-09 Cont ID  
Sent By jgomez Date 2010-11-09 Time 15:39 Rev Time 0.00
Received By jgomez Date 2010-11-09 Time 15:39 Sent To B
Notes
2010-11-09 15:40:08SENT TO JULIO'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-10-29 Cont ID  
Sent By lmartine Date 2010-10-28 Time 09:34 Rev Time 0.00
Received By lmartine Date 2010-10-14 Time 15:28 Sent To  
Notes
2010-10-14 15:34:30R9

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2010-11-10 Cont ID  
Sent By jgomez Date 2010-11-10 Time 14:38 Rev Time 0.00
Received By jgomez Date 2010-11-10 Time 14:38 Sent To  
Notes
2010-11-10 14:39:36ZERO FEES DUE. PLANS ESTAMPED BY M. BONNANI ON
 10/29/10.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2010-10-20 Cont ID  
Sent By jgomez Date 2010-10-20 Time 15:46 Rev Time 0.00
Received By jgomez Date 2010-10-20 Time 15:46 Sent To  
Notes
2010-10-20 15:47:581- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2010-10-21 Cont ID  
Sent By jgomez Date 2010-10-21 Time 08:58 Rev Time 0.00
Received By jgomez Date 2010-10-21 Time 08:58 Sent To  
Notes
2010-10-21 08:58:56NO MECHANICAL WORK SHOWN ON PLANS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-10-21 Cont ID  
Sent By jgomez Date 2010-10-21 Time 09:00 Rev Time 0.00
Received By jgomez Date 2010-10-21 Time 09:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2010-10-12 Time   Rev Time  
Received By   Date 2010-10-12 Time   Sent To  
Notes
***NONE***