Plan Review Details - Permit 10100237
Plan Review Stops For Permit 10100237
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-12-27 Cont ID  
Sent By jwitmer Date 2010-12-27 Time 08:14 Rev Time 1.55
Received By jwitmer Date 2010-12-15 Time 13:03 Sent To  
Notes
2010-12-27 08:16:22PASSED PER MEETING HELD WITH VALCOM & DESIGN TEAM,
 QUESTIONS FOR ZONING ANSWERED, NEW PLANS TO BE ENTERED
 INTO SET THIS WEEK.
 JW

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-01-24 Cont ID  
Sent By rlecky Date 2011-01-24 Time 08:38 Rev Time 0.00
Received By rlecky Date 2011-01-24 Time 08:16 Sent To  
Notes
2011-01-24 08:38:24PROVISO:
 THE SMOKE DETECTORS MUST BE INTERCONNECTED. FBC R313.2
  
 ROBERT LECKY, ELECTRICAL PLANS REVIEW, 561-805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-12-09 Cont ID  
Sent By rlecky Date 2010-12-09 Time 09:58 Rev Time 0.00
Received By rlecky Date 2010-12-08 Time 12:13 Sent To  
Notes
2010-12-08 14:54:59CLOTHES WASHERS APPEAR TO BE LOCATED WITHIN THE SAFE
 WORKING ACCESS TO THE EXISTING ELECTRICAL PANELBOARDS.
 NEC 110-26
 VERIFY THE EXISTING ELECTRICAL SERVICE , FEEDERS,
 DISCONNECTS , AND GROUNDING SYSTEM ARE SUITABLE FOR
 REUSE. NEC 230.2, 230.23, 230.42, 230.71, 250.20,
 250.53, 250.66
 HEATING OR COOLING LOADS HAVE NOT BEEN APPLIED TO THE
 EXISTING ELECTRICAL CAPACITY. WILL HEATING OR COOLING
 BE UTILIZED WITHIN THESE DWELLINGS? NEC 230-23
  
 R. LECKY, PLANS EXAMINER, 561-805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2011-02-17 Cont ID  
Sent By wjolin Date 2011-02-17 Time 09:07 Rev Time 0.00
Received By wjolin Date 2011-02-17 Time 09:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2011-02-08 Cont ID  
Sent By wjolin Date 2011-02-08 Time 16:23 Rev Time 0.00
Received By wjolin Date 2011-02-08 Time 15:16 Sent To  
Notes
2011-02-08 16:23:17PERMIT #10100237
 REVIEW COMMENTS - FIRE
 2ND REVIEW
  
  
 REPEAT COMMENT: FIRE AND LIFE SAFETY REQUIREMENTS TO
 CONFORM TO THE FLORIDA FIRE PREVENTION CODE 2007
 EDITION. A NOTE COULD NOT BE LOCATED ON THE TITLE
 SHEET.
  
 REPEAT COMMENT: ALL DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. A NOTE COULD NOT BE
 LOCATED ON THE TITLE SHEET.
  
 REPEAT COMMENT: FIRE EXTINGUISHERS SHALL BE SERVICED
 AND TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. A
 NOTE COULD NOT BE LOCATED ON THE TITLE SHEET.
  
 SMOKE DETECTORS ARE REFERENCED ON SEVERAL SHEETS.
 VERIFY IT IS THE DESIGN INTENT TO INSTALL SMOKE ALARMS
 IN LIEU OF SMOKE DETECTORS.
  
 CONSTRUCTION TYPE LISTED AST TYPE IV ON COVER SHEET.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-11-16 Cont ID  
Sent By wjolin Date 2010-11-16 Time 10:35 Rev Time 0.00
Received By wjolin Date 2010-11-12 Time 12:24 Sent To  
Notes
2010-11-12 13:33:26PERMIT #10100237
 REVIEW COMMENTS - FIRE
  
  
 FIRE AND LIFE SAFETY REQUIREMENTS TO CONFORM TO THE
 FLORIDA FIRE PREVENTION CODE 2007 EDITION.
  
 ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS
 OF NFPA 241.
  
 SMOKE ALARM INSTALLATION TO CONFORM TO THE REQUIREMENTS
 OF NFPA 72.
  
 FIRE EXTINGUISHERS SHALL BE SERVICED AND TAGGED BY A
 LICENSED FIRE EXTINGUISHER COMPANY.
  
 CARBON MONOXIDE ALARMS REQUIRED TO BE INSTALLED WITHIN
 10 FEET OF SLEEPING ROOMS FOR APARTMENTS UTILIZING GAS
 RANGES OR GAS WATER HEATERS (FS553.885).
  
 MANY OF THE NEW BATHROOM DOORS HAVE A DOOR SWING THAT
 OBSTRUCTS MORE THAN 50 PERCENT OF THE EGRESS PATH FOR
 THE OCCUPANTS IN ADJACENT BEDROOMS (FFPC: NFPA 101
 SECTION 7.2.1.4.4).
  
 STAIRS EXCEEDING 30-INCHES ABOVE THE GROUND REQUIRE
 GUARDS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
 (561) 805-6730

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2010-12-14 Cont ID  
Sent By lwagner Date 2010-12-14 Time 07:39 Rev Time 0.00
Received By lwagner Date 2010-12-14 Time 07:39 Sent To  
Notes
2010-12-14 07:40:33GAS PERMIT REQUIRED

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-02-17 Cont ID  
Sent By wjolin Date 2011-02-17 Time 09:05 Rev Time 0.00
Received By wjolin Date 2011-02-17 Time 09:05 Sent To FIRE
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-01-21 Cont ID  
Sent By lmartine Date 2011-01-21 Time 16:09 Rev Time 0.00
Received By lmartine Date 2011-01-21 Time 16:09 Sent To  
Notes
2011-01-21 16:09:41C--6

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-10-29 Cont ID  
Sent By jwitmer Date 2010-10-29 Time 16:12 Rev Time 0.00
Received By jwitmer Date 2010-10-29 Time 16:11 Sent To  
Notes
2010-10-29 16:11:42INCOMING SENT TO C-9. JW

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2010-12-21 Cont ID  
Sent By rkussner Date 2010-12-21 Time 08:43 Rev Time 0.00
Received By rkussner Date 2010-12-21 Time 08:43 Sent To  
Notes
2010-12-21 08:46:15***LANDSCAPE REVIEW NOT REQUIRED***
  
 THE COST OF IMPROVEMENTS DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE WHICH WOULD TRIGGER A FULL SITE
 UPGRADE. SHOULD ANY OF THE IMPROVEMENTS CONFLICT WITH
 ANY EXITIING TREES OR LANDSCAPING, A FURTHER LANDSCAPE
 REVIEW WILL BE REQUIRED---RAK

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-12-13 Cont ID  
Sent By lwagner Date 2010-12-13 Time 14:39 Rev Time 0.00
Received By lwagner Date 2010-12-10 Time 15:32 Sent To  
Notes
2010-12-13 10:30:29*****PROVISO*****
 1. THE BRANCH AND STACK FOR THE WASHING MACHINE IS
 REQUIRED TO BE 3" FBC PLUMBING 406.3
  

Review Stop Z ZONING
Rev No 2 Status P Date 2011-02-07 Cont ID  
Sent By jroach Date 2011-02-07 Time 15:22 Rev Time 0.00
Received By jroach Date 2011-02-07 Time 15:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-12-06 Cont ID  
Sent By jroach Date 2010-12-06 Time 14:14 Rev Time 0.00
Received By jroach Date 2010-12-06 Time 14:13 Sent To  
Notes
2010-12-06 14:14:13ZONING PLAN REVIEW
  
 DATE OF REVIEW: 12/06/2010
 PERMIT NO.: 10100237
 ADDRESS: 3949 GEORGIA AVENUE
 CONTRACTOR/CONTACT: LUIS R. VALDERRAMA
 TELEPHONE NO.: 561.586.2844
 SCOPE OF REVIEW: MODIFICATION TO INTERIOR OF 73 UNITS
 TO COMPLY WITH UFA AND ALTERATION TO EXTERIOR SIDEWALK
 FOR CONFORMANCE WITH UFA.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) IT APPEARS THAT PERMIT APPLICATIONS HAVE BEEN
 SUBMITTED FOR EACH BUILDING THAT IS HAVING WORK
 PERFORMED, BUT NO PERMIT WAS APPLIED FOR THE SITE WORK.
 A SEPARATE BUILDING PERMIT APPLICATION SHOULD BE
 SUBMITTED FOR THE SITE WORK TO BE PERFORMED FOR THE
 COMMON AREAS (OUTSIDE OF THE EXTERIOR BUILDING WALLS)
 (I.E. SIDEWALKS, RAMPS, PORCHES/PATIOS, ETC.).
  
 2) FOR EACH BUILDING PERMIT APPLICATION, THE PROJECT
 DESCRIPTION SHOULD ACCURATELY REFLECT THE WORK THAT IS
 BEING DONE SOLELY WITHIN THAT BUILDING. IT APPEARS THAT
 THE PERMIT APPLICATION WAS DUPLICATED TO REFLECT ALL
 WORK BEING DONE, AND IS NOT AN ACCURATE DESCRIPTION OF
 THE WORK BEING DONE WITHIN THAT SPECIFIC BUILDING.
  
 3) IT IS UNCLEAR ON THE SITE PLANS AS TO WHAT IS
 EXISTING AND WHAT IS BEING PROPOSED. PLEASE DISTINGUISH
 WHAT WORK IS BEING PROPOSED IN RELATION TO WHAT
 IMPROVEMENTS ARE EXISTING.
  
 4) NUMEROUS RAMPS, STAIRS, RAILINGS, ETC. APPEAR TO
 ENCROACH INTO THE FRONT SETBACKS ALONG SOUTHERN
 BOULEVARD AND ROSELAND DRIVE. PURSUANT TO SECTION
 94-305(B)(7) OF THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS, STEPS, OPEN UNCOVERED PORCHES
 OR STOOPS, ETC. THAT ARE THREE (3) FEET OR LESS ABOVE
 GRADE MAY ENCROACH INTO ANY REQUIRED SETBACK TO A POINT
 NOT CLOSER THAN TWO (2) FEET TO THE PROPERTY LINE.
 PLEASE PROVIDE THE DIMENSION FROM GRADE TO THE TOP OF
 THE STEPS/PORCH/STOOP FOR EACH BUILDING. IF THE GRADE
 DIFFERENTIAL IS GREATER THAN THREE (3) FEET, THEY SHALL
 MEET SETBACK REQUIREMENTS FOR PRIMARY STRUCTURES. NOTE:
 THE CURRENT STAIR RAILINGS DETAIL ON SHEET A1.6 REFERS
 TO THE RISER SCHEDULE ON THE QUADRANT PLANS; HOWEVER,
 THE RISER SCHEDULE DOES NOT PROVIDE THE INFORMATION FOR
 ALL OF THE BUILDINGS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved