Plan Review Details - Permit 10100127
Plan Review Stops For Permit 10100127
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-17 Time 10:26 Rev Time 0.00
Received By rmcdouga Date 2010-11-17 Time 10:26 Sent To  
Notes
2010-11-17 10:28:36BUILDING PROVISO
  
 1) POOL BARRIER REQUIREMENTS IN COMPLIANCE WITH FBC
 R4101.07 AND FS 515 SHALL BE IN PLACE AT FINAL
 INSPECTION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-17 Time 10:25 Rev Time 0.00
Received By rmcdouga Date 2010-11-17 Time 10:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-11-22 Cont ID  
Sent By lmartine Date 2010-11-22 Time 13:22 Rev Time 0.00
Received By lmartine Date 2010-11-22 Time 13:22 Sent To  
Notes
2010-11-22 13:23:05IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-17 Time 10:26 Rev Time 0.00
Received By rmcdouga Date 2010-10-08 Time 10:56 Sent To  
Notes
2010-10-08 10:57:14SENT TO ZONING BOX.

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-11-30 Cont ID  
Sent By rmcdouga Date 2010-11-30 Time 14:54 Rev Time 0.00
Received By rmcdouga Date 2010-11-30 Time 14:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-17 Time 09:51 Rev Time 0.00
Received By rmcdouga Date 2010-11-16 Time 14:26 Sent To  
Notes
2010-11-17 10:25:532007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) SUBMIT 2 COPIES OF SPECIFICATIONS FOR EACH OF THE
 PUMPS THAT WILL BE INSTALLED. INCLUDE THE PUMP CURVES
 FOR THE PUMPS.
  
 2) SUBMIT 2 COPIES OF TOTAL DYNAMIC HEAD (TDH)
 CALCULATIONS FROM THE DESIGNER OF RECORD FOR EACH OF
 THE PUMPS. OTHERWISE THE MAXIMUM PUMP CAPACITY IN GPM
 WILL BE USED TO DETERMINE THE FLOW RATE.
  
 3) UNDER AUX. POOL SPECS ON DRAWING 1, A SHARED 2.0 HP
 PUMP IS SPECIFIED. THE REST OF THE PLANS SPECIFY A
 1-1/2 HP PUMP FOR THE POOL AND A 1-1/2 HP PUMP FOR THE
 VANISHING EDGE. PLEASE CLARIFY.
  
 4) THE VANISHING EDGE DETAIL ON DRAWING 3 SPECIFIES TWO
 8" DRAINS AND THE OTHER DRAWINGS SHOW A CHANNEL DRAIN.
 PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2010-11-30 Cont ID  
Sent By ajones Date 2010-11-30 Time 11:42 Rev Time 0.00
Received By ajones Date 2010-11-29 Time 16:39 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-10-26 Cont ID  
Sent By lfranco Date 2010-10-26 Time 18:29 Rev Time 0.00
Received By lfranco Date 2010-10-14 Time 18:20 Sent To B
Notes
2010-10-26 18:35:03PLANNING AND ZONING: **** FAILED ******
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PROVIDE DIMENSIONS TO ALL PROPERTY LINES OF POOL
 (EQUIPMENT) ON BOTH THE SURVEY AND SITE PLAN. PURSUANT
 TO SECTION 94-305(B)(4) OF THE ZLDR: MECHANICAL
 EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A
 REQUIRED SETBACK.
  
 3. THE SURVEY SHOWS A NEW PERMANENT FENCE TO SURROUND
 THE POOL, HOWEVER, AN APPLICATION FOR A SEPARATE FENCE
 PERMIT SHALL BE APPLIED FOR CONCURRENTLY WITH THIS
 PERMIT AND SHALL CONFORM TO THE MINIMUM STANDARDS
 PROVIDED BELOW:
 NOTE, VERY IMPORTANT: REFERENCE THIS PERMIT AS THE
 MASTER PERMIT WHEN SUBMITTING FOR THE FENCE PERMIT AND
 PROVIDE LOCATION OF POOL. ADD NOTATION ON THE FENCE
 PERMIT THAT THE APPLICATION OF THE FENCE PERMIT IS TO
 COMPLY WITH THE COMMENTS OF THE POOL PERMIT.
  
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND
 (C):
 B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT
 LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN
 ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH
 AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL
 BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT,
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  