Plan Review Details - Permit 10100116
Plan Review Stops For Permit 10100116
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-11-18 Cont ID  
Sent By rmcdouga Date 2010-11-18 Time 16:16 Rev Time 0.00
Received By rmcdouga Date 2010-11-18 Time 16:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-11-09 Cont ID  
Sent By rmcdouga Date 2010-11-09 Time 08:50 Rev Time 0.00
Received By rmcdouga Date 2010-11-09 Time 08:50 Sent To  
Notes
2010-11-09 08:51:052007 FBC W/2009 REVISIONS
  
 COMMENTS FROM FIRST REVIEW WERE NOT ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-10-21 Cont ID  
Sent By rmcdouga Date 2010-10-21 Time 12:12 Rev Time 0.00
Received By rmcdouga Date 2010-10-21 Time 12:12 Sent To  
Notes
2010-10-21 12:19:542007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE POOL DOES NOT COMPLY WITH FBC R4101.18. IN
 PRIVATE POOLS WHERE WATER DEPTH EXCEEDS 5 FEET, THERE
 SHALL BE LADDERS, STAIRS OR UNDERWATER BENCHES/SWIMOUTS
 IN THE DEEP END. THE 4" DEEP SUN SHELF AT THE DEEP END
 DOES NOT FULFILL THIS REQUIREMENT.
  
 2) THE VALUE FOR THE POOL SPECIFIED ON THE PERMIT
 APPLICATION APPEARS TO BE LOW. PLEASE SUBMIT A COPY OF
 THE SIGNED CONTRACT FOR VERIFICATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-10-21 Cont ID  
Sent By rmcdouga Date 2010-10-21 Time 12:03 Rev Time 0.00
Received By rmcdouga Date 2010-10-21 Time 12:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-11-01 Cont ID  
Sent By jgomez Date 2010-11-01 Time 15:59 Rev Time 0.00
Received By jgomez Date 2010-11-01 Time 15:59 Sent To  
Notes
2010-11-01 15:59:58SENT TO R. MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-10-21 Cont ID  
Sent By rmcdouga Date 2010-10-21 Time 13:20 Rev Time 0.00
Received By rmcdouga Date 2010-10-06 Time 16:15 Sent To  
Notes
2010-10-06 16:15:25INCOMING SENT TO ZONING BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2010-11-18 Cont ID  
Sent By rmcdouga Date 2010-11-18 Time 16:16 Rev Time 0.00
Received By rmcdouga Date 2010-11-18 Time 16:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2010-11-09 Cont ID  
Sent By rmcdouga Date 2010-11-09 Time 08:48 Rev Time 0.00
Received By rmcdouga Date 2010-11-09 Time 08:48 Sent To  
Notes
2010-11-09 08:50:352007 FBC W/2009 REVISIONS
  
 COMMENTS FROM FIRST REVIEW WERE NOT ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-10-21 Cont ID  
Sent By rmcdouga Date 2010-10-21 Time 13:04 Rev Time 0.00
Received By rmcdouga Date 2010-10-21 Time 13:04 Sent To  
Notes
2010-10-21 13:15:42DENIED BY PLUMBING
  
 1) THE PLANS SPECIFY A JANDY MODEL MHPM 1.0 POOL PUMP
 WITH A FLOW RATE OF 70 GPM WITH A TDH OF 50. PLEASE
 SUBMIT 2 COPIES OF THE TDH CALCULATIONS THAT WERE USED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2010-10-13 Cont ID  
Sent By astelly Date 2010-10-13 Time 18:08 Rev Time 0.00
Received By astelly Date 2010-10-13 Time 18:08 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy