Plan Review Details - Permit 10100056
| Plan Review Stops For Permit 10100056 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-12-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-28 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-28 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-11-02 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-11-02 |
Time |
09:27 |
Sent To |
FIRE |
|
| Notes |
| 2010-11-02 09:51:15 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE A SITE PLAN SHOWING PROPOSED IMPROVEMENT | | | LOCATION, FBC106. | | | | | | 2. PLEASE REVISE PLAN TO SHOW HOW THE PROPOSED | | | IMPROVEMENT WILL AFFECT EXITING, FBC CH. 10, FBC CH. | | | 11. STAIRS SHOWN, BUT NO INFORMATION PROVIDED REGARDING | | | AREA SERVED, AND NO INFORMATION SHOWN REGARDING DEMO OR | | | INSTALLATION OF NEW DOORS. INCLUDE ENOUGH INFORMATION | | | REQUIRED TO DEMONSTRATE CODE COMPLIANCE. | | | | | | 3. SHOW DISTANCE FROM PROPOSED LANDING TO FINISHED | | | FLOOR OF AREA WHICH THE PROPOSED STAIR WILL SERVE. | | | | | | 4. PROIVDE A DETAIL FOR THE GUARD/HAND RAIL, FBC 1012, | | | 1012.5, 1013, 11-4.8.5. | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-12-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-12-20 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-12-20 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-11-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-11-03 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-11-03 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2010-11-03 10:07:20 | 2406 FLORIDA AVENUE | | | PERMIT #10100056 | | | | | | REVIEW COMMENTS - FIRE | | | | | | 1) PROVIDE NEW STAIR PER CHAPTER 7 OF THE FLORIDA FIRE | | | PREVENTION CODE 2007 EDITION (NFPA 101- LIFE SAFETY | | | CODE 2006 EDITION WITH FLORIDA AMENDMENTS). | | | | | | 2) STAIRS SHALL HAVE HANDRAILS ON BOTH SIDES PER | | | 7.2.2.4.1.1 (FFPC - NFPA 101). | | | | | | 3) NEW HANDRAIL ENDS SHALL BE RETURNED TO THE WALL OR | | | FLOOR OR SHALL TERMINATE AT NEWEL POSTS PER 7.2.2.4.4.9 | | | (FFPC - NFPA 101). | | | | | | 4) OUTSIDE STAIRS AND LANDINGS SHALL BE DESIGNED TO | | | MINIMIZE WATER ACCUMULATION OF THEIR SURFACES PER | | | 7.2.2.6.5 (FFPC - NFPA 101). | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | 561-805-6730 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-12-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-12-09 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-12-09 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-11-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-11-03 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-11-03 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2010-10-06 11:11:28 | SENT TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-12-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2010-12-22 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2010-12-22 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-10-12 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2010-10-12 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2010-10-06 |
Time |
17:12 |
Sent To |
B |
|
| Notes |
| 2010-10-12 11:49:15 | ZONING PLAN REVIEW | | | | | | DATE OF REVIEW: 10/12/2010 | | | PERMIT NO.: 10100056 | | | ADDRESS: 2406 FLORIDA AVENUE | | | CONTRACTOR/CONTACT: J. RICHARD MCDONALD | | | TELEPHONE NO.: 561.795.4055 | | | SCOPE OF REVIEW: CONSTRUCT 2 NEW CONCRETE STAIRS AND | | | REPAIR 1 SET OF CONCRETE STAIRS AND INSTALL NEW | | | HANDRAIL SYSTEMS. | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1) PLEASE PROVIDE TWO (2) COPIES OF CURRENT AND | | | ACCURATE SURVEY. THE SURVEY SHALL INDICATE THE LOCATION | | | OF THE NEW AND REPAIRED STAIRS. BE SURE TO PROVIDE | | | DIMENSIONS FROM EACH PROPERTY LINE TO THE CLOSEST POINT | | | OF EACH STAIR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
|