| Plan Review Stops For Permit 10090585 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-12-21 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-12-21 |
Time |
11:33 |
Sent To |
PC |
|
| Notes |
| 2010-12-21 13:32:07 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- PROVIDE COMPLETE INFORMATION FOR FLAT ROOF UNDER A | | | SEPARATE ROOFING PERMIT. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS PRIOR | | | TO SUBMITTAL TO THIS OFFICE AS REQUIRED BY SEC. 106.3.3 | | | CITY AMENDMENTS TO FBC. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-07 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-07 |
Time |
14:38 |
Sent To |
PC |
|
| Notes |
| 2010-10-07 15:31:49 | RESIDENTIAL (R3) REPAIRS/RENOVATION/ALTERATION BUILDING | | | REVIEW CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- PROVIDE THE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | N1100.3 OF 2007 FLORIDA RESIDENTIAL CODE. | | | ***NOTE: PLEASE MAKE SURE CORRECT UPDATED FORM IS USED | | | AND FILL ALL THE INFORMATION ON THE FORM. | | | | | | 3- PROVIDE PRODUCT APPROVALS AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | | | | A) WINDOW MULLIONS. AND CLEARLY MARK ON MULLION | | | DRAWINGS SPECIFIC MULLION SIZE AND FASTENERS TO VERIFY | | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF | | | 2007 FLORIDA RESIDENTIAL CODE. | | | | | | B) ARCHED WINDOWS AS SHOWN ON PLANS. NOA 08-0917.08 | | | SUBMITTED IS FOR RECTANGULAR WINDOWS ONLY. AND PROVIDE | | | 2 COPIES. | | | | | | C) SINGLE HUNG WINDOWS. ONLY ONE NOA WAS SUBMITTED. | | | NEED TWO COPIES. | | | | | | D) FLAT ROOF ASSEMBLY: AND (1) CLEARLY MARK WHICH | | | APPROVED ASSEMBLY IS GOING TO BE INSTALLED. (2) PROVIDE | | | RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER | | | AND CORNER AREAS. (3) RAS 117 CALCULATIONS TO BE SIGNED | | | AND SEALED IF GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | REQUIRES THEM TO BE SIGNED AND SEALED. ***NOTE: | | | ASSEMBLIES WITH GENERAL LIMITATION #9 CAN'T BE USED IN | | | THIS BUILDING. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS PRIOR | | | TO SUBMITTAL TO THIS OFFICE AS REQUIRED BY SEC. 106.3.3 | | | CITY AMENDMENTS TO FBC. | | | | | | 5- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO | | | CHECK IF IMPACT FEES ARE DUE WHEN CONVERTING THE PORCH | | | TO LIVING SPACE. BRING BACK STAMPED PLANS AND COPY OF | | | PAID RECEIPT IF FEES ARE DUE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-12-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-12-10 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-12-10 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-10-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-10-04 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-10-04 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2010-10-04 09:19:33 | PLAN SHOWS NO OUTLETS OR LIGHTS | | | | | | BOTH ARE REQUIRED BY THE NEC 210.52, 210.70 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-12-21 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2010-12-21 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2010-12-21 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2010-12-21 14:40:03 | ****APPROVED WITH PROVISO**** | | | | | | 1. THE WIDTH OF THE ARCHED, STUCCO BANDING ON THE FRONT | | | ELEVATION SHALL BE REDUCED TO REFLECT THE COLUMN WIDTH, | | | RATHER THAN THE CAPITOL WIDTH. CONTACT JILLIAN PAPA FOR | | | MORE INFORMATION. | | | | | | JILLIAN PAPA | | | HISTORIC PRESERVATION PLANNER | | | 561.822.1454 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-09-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2010-09-22 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2010-09-22 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-12-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-12-09 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-12-09 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2010-12-10 19:53:44 | 12/10 TO JG DESK | | 2010-12-09 16:53:13 | GAVE TO JAKE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-07 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-09-23 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2010-09-23 10:50:36 | SENT TO R2. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2010-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-12-21 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-12-21 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2010-12-21 11:46:48 | CHANGED TO OPEN PORCH. NO SUNROOM. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-07 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-07 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2010-10-07 14:41:56 | RESIDENTIAL (R3) CONVERSION FROM PORCH TO SUN ROOM: | | | | | | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO | | | VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS | | | AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-07 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-07 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2010-10-07 15:35:25 | NO MECHANICAL WORK SHOWN ON PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-07 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-07 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2010-10-07 15:36:03 | NO PLUMBING WORK SHOWN ON PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-09-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2010-09-22 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2010-09-22 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|