Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-10-18 Cont ID  
Sent By shill Date 2010-10-18 Time 08:46 Rev Time 0.00
Received By shill Date 2010-10-18 Time 08:46 Sent To  
Notes
2010-10-18 08:49:04****PROVISO****
 ***REVISION REQUIRED***
 ***ISSUED AT CONTRACTOR'S RISK****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 REVISE PLAN TO EXPOSURE C WIND DESIGN OR PROVIDE AN
 ENGINEERING ANALYSIS TO JUSTIFY EXPOSURE B DESIGN.
  
 FBC1609, FBC R301.2.1.4, ASCE 7-05.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-10-18 Cont ID  
Sent By shill Date 2010-10-18 Time 09:32 Rev Time 0.00
Received By shill Date 2010-09-20 Time 16:20 Sent To  
Notes
2010-09-20 16:20:26ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2010-09-30 Cont ID  
Sent By jroach Date 2010-09-30 Time 12:29 Rev Time 0.00
Received By jroach Date 2010-09-24 Time 14:40 Sent To B
Notes
***NONE***