| 2010-09-15 13:55:22 | BUILDING PLAN REVIEW |
| | PERMIT: 10090234 |
| | ADD: 477 ROSEMARY AVE SUITE# 205/207/209/211/213/215) |
| | CONT: TBD |
| | CONTACT MIKE STELLINO |
| | TEL: (561)650-0900 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW: DENIED |
| | |
| | 1) CONTRACTOR WILL NEED TO BE SIGNED ONTO THE PROJECT |
| | AND LICENSURE REVIEWED. |
| | |
| | 2) PLANS WILL NEED TO BE REVIEWED BY CITY PLACE AND |
| | THEIR STAMP AFFIXED. |
| | |
| | 3) PLANS WILL NEED TO BE REVIEWED BY PALM BEACH COUNTY |
| | IMPACT FEE OFFICE FOR ASSESSMENT. IT APPEARS THAT NONE |
| | OF THESE SPACES HAVE BEEN REVIEWED BY P B COUNTY |
| | FOR CHANGE OF OCCUPANCY. OUR RECORDS INDICATE: |
| | 07060304 UNIT# 207 -EXPIRED NEVER ISSUED |
| | 08080246 UNIT# 209 -EXPIRED NEVER ISSUED |
| | 03110332 UNITS 213& 215, ISSUED BUT NO IMPACT FEE STAMP |
| | ON PLANS NOR COUNTY RECEIPT |
| | |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | GYPSUM BOARDS IN SHOWERS & WATER CLOSETS |
| | |
| | 2509.1 WET AREAS. SHOWERS AND PUBLIC TOLIET WALLS SHALL |
| | CONFORM TO SECTION 1210.2 AND 1210.3. |
| | |
| | 2509.2 BASE FOR TILE. CEMENT, FIBER-CEMENT OR GLASS MAT |
| | GYPSUM BACKERS IN COMPLIANCE WITH |
| | |
| | ASTM C 1178-08 STANDARD SPECIFICATION |
| | FOR COATED GLASS MAT WATER-RESISTANT GYPSUM |
| | |
| | ASTM C 1288-99 STANDARD SPECIFICATION |
| | FOR DISCRETE NON- ASBESTOS FIBER-CEMENT INTERIOR |
| | SUBSTRATE SHEETS |
| | |
| | ASTM C 1325-08 STANDARD SPECIFICATION |
| | FOR NON-ASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS |
| | BACKER UNITS |
| | |
| | AND INSTALLED IN ACCORDANCE WITH MANUFACTURER |
| | RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE |
| | IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN |
| | SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD |
| | SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET |
| | COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH |
| | GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS. |
| | REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR |
| | WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN |
| | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840. |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC |