Plan Review Details - Permit 10090213
| Plan Review Stops For Permit 10090213 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-10-01 |
Time |
14:47 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2010-10-01 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2010-10-01 15:11:37 | ROOFING: | | | | | | BUILDING PROVISO: | | | 1507.2.8 UNDERLAYMENT APPLICATION. FOR ROOF SLOPES FROM | | | TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT | | | SLOPE) AND UP TO FOUR UNITS VERTICAL IN 12 UNITS | | | HORIZONTAL (33-PERCENT SLOPE), UNDERLAYMENT SHALL BE | | | TWO LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A | | | MINIMUM 19-INCH-WIDE (483 MM) STRIP OF UNDERLAYMENT | | | FELT PARALLEL WITH AND STARTING AT THE EAVES, FASTENED | | | SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, | | | APPLY 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT | | | OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM), BY | | | FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN | | | THE UNDERLAYMENT SHALL NOT INTERFERE WITH THE ABILITY | | | OF THE SHINGLES TO SEAL. FOR ROOF SLOPES OF FOUR UNITS | | | VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE) OR | | | GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE | | | FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE | | | FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND | | | LAPPED 2 INCHES (51 MM), FASTENED SUFFICIENTLY TO HOLD | | | IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT | | | INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL. | | | | | | FL-10124-R1 | | | GAF | | | ASPHALT SHINGLES |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-10-01 |
Time |
14:48 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2010-10-01 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-10-01 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-09-10 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-09-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-09-28 |
Time |
16:20 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2010-09-28 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2010-09-28 16:20:43 | ADONIDIA PALM SHALL BE RELOCATED ON-SITE IF NEW ENTRY | | | INTERFERES WITH THE CURRENT PLACEMENT. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |