| 2010-10-05 15:55:30 | BUILDING PLAN REVIEW |
| | PERMIT: 10090080 |
| | ADD: 926 SUNSET RD |
| | CONT: O/B MARIA GEORGE |
| | TEL: (561)718-4600 |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | SHED PERMIT: 2578J 18???X18??? 11-1-84 ORIGINAL PERMIT |
| | FOR SHED. |
| | |
| | THIS REVIEW WILL USE THE 2007 EXISTING BUILDING CODE |
| | CHAPTER 9 CHANGE IN OCCUPANCY FOR THE BASIS OF THIS |
| | REVIEW. EX. BLDG CODE 901.3 CHANGE OF OCCUPANCY |
| | CLASSIFICATION. WHERE THE OCCUPANCY CLASSIFICATION OF A |
| | BUILDING CHANGES, THE PROVISIONS OF SECTIONS 902 |
| | THROUGH 912 SHALL APPLY. THIS INCLUDES A CHANGE OF |
| | OCCUPANCY CLASSIFICATION WITHIN A GROUP AS WELL AS A |
| | CHANGE OF OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A |
| | DIFFERENT GROUP. |
| | |
| | EX. BLDG CODE 903.1 GENERAL. BUILDING ELEMENTS AND |
| | MATERIALS IN PORTIONS OF BUILDINGS UNDERGOING A CHANGE |
| | OF OCCUPANCY CLASSIFICATION SHALL COMPLY WITH SECTION |
| | 912. |
| | |
| | EX. BLDG CODE 905.1 GENERAL. MEANS OF EGRESS IN |
| | PORTIONS OF BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY |
| | CLASSIFICATION SHALL COMPLY WITH SECTION 912. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1 INDICATES THE SHED WAS BUILT IN THE |
| | 1980???S AND COMPLIANT TO THE SBCCI WIND PROVISIONS. |
| | PLEASE VISIT EX. BLDG CODE 907.2 WIND LOADS. BUILDINGS |
| | AND STRUCTURES SUBJECT TO A CHANGE OF OCCUPANCY WHERE |
| | SUCH CHANGE IN THE NATURE OF OCCUPANCY RESULTS IN |
| | HIGHER WIND IMPORTANCE FACTORS BASED ON THE FLORIDA |
| | BUILDING CODE, BUILDING TABLE 1604.5, SHALL BE ANALYZED |
| | AND SHALL COMPLY WITH THE APPLICABLE WIND LOAD |
| | PROVISIONS OF THE FLORIDA BUILDING CODE, BUILDING . |
| | SINCE THE ORIGINAL SHED WAS BUILT AS A NON-HABITUAL |
| | STRUCTURE THE IMPORTANCE FACTOR OF 0.77 WOULD HAVE BEEN |
| | USED, NOW THE BUILDING CLASSIFICATION OR CATEGORY IS |
| | NOW II AND A 1.00. PLEASE PROVIDE WIND DESIGN CRITERIA |
| | WITH PRESSURES FOR WINDOWS AND DOORS. FBC-R TABLE |
| | 301.2(2) |
| | |
| | 2) EXISTING BUILDING CODE SECTION 912.1.1 COMPLIANCE |
| | WITH CHAPTER 8. THE REQUIREMENTS OF CHAPTER 8 SHALL BE |
| | APPLICABLE THROUGHOUT THE BUILDING FOR THE NEW |
| | OCCUPANCY CLASSIFICATION BASED ON THE SEPARATION |
| | CONDITIONS SET FORTH IN SECTIONS 912.1.1.1 AND |
| | 912.1.1.2. |
| | |
| | 801.2 COMPLIANCE. IN ADDITION TO THE PROVISIONS OF THIS |
| | CHAPTER, WORK SHALL COMPLY WITH ALL OF THE REQUIREMENTS |
| | OF CHAPTERS 6 AND 7. |
| | |
| | 2007EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING/ RESIDENTIAL. |
| | |
| | 3) EX. BLDG CODE 912.1.2 FIRE PROTECTION AND INTERIOR |
| | FINISH. THE PROVISIONS OF SECTIONS 912.2 AND 912.3 FOR |
| | FIRE PROTECTION AND INTERIOR FINISH, RESPECTIVELY, |
| | SHALL APPLY TO ALL BUILDINGS UNDERGOING A CHANGE OF |
| | OCCUPANCY CLASSIFICATION. PLEASE REVIEW FBC- R 315. |
| | |
| | 3A) EX. BUILDING CODE 912.2.2 FIRE ALARM AND DETECTION |
| | SYSTEM. WHERE A CHANGE IN OCCUPANCY CLASSIFICATION |
| | OCCURS THAT REQUIRES A FIRE ALARM AND DETECTION SYSTEM |
| | TO BE PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE |
| | WITH CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING , |
| | SUCH SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE |
| | THE CHANGE OF OCCUPANCY OCCURS. PLANS FAIL TO INDICATE |
| | SMOKE DETECTORS WITHIN THE BEDROOM AND OUTSIDE OF THE |
| | BEDROOM. |
| | |
| | R313.1 SMOKE DETECTION AND NOTIFICATION. ALL SMOKE |
| | ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 217 AND |
| | INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS |
| | CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT |
| | PROVISIONS OF NFPA 72. |
| | R313.2 LOCATION. SMOKE ALARMS SHALL BE INSTALLED IN THE |
| | FOLLOWING LOCATIONS: |
| | 1. IN EACH SLEEPING ROOM. |
| | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE |
| | VICINITY OF THE BEDROOMS. |
| | |
| | 3B) EX. BLDG CODE 912.3 INTERIOR FINISH. IN AREAS OF |
| | THE BUILDING UNDERGOING THE CHANGE OF OCCUPANCY |
| | CLASSIFICATION, THE INTERIOR FINISH OF WALLS AND |
| | CEILINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING , FOR THE NEW OCCUPANCY |
| | CLASSIFICATION. |
| | |
| | 4) EX. BLDG CODE 912.4.1 MEANS OF EGRESS FOR CHANGE TO |
| | HIGHER HAZARD CATEGORY. WHEN A CHANGE OF OCCUPANCY |
| | GROUP IS MADE TO A HIGHER HAZARD CATEGORY (LOWER |
| | NUMBER) AS SHOWN IN TABLE 912.4, THE MEANS OF EGRESS |
| | SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 10 OF THE |
| | FLORIDA BUILDING CODE, BUILDING . UTILITY 5 LOWEST |
| | HAZARD TO A 4 R-3 OCCUPANCY. |
| | |
| | EXCEPTIONS:7 . WHERE EMERGENCY ESCAPE AND RESCUE |
| | OPENINGS ARE REQUIRED, AN EXISTING OPERABLE WINDOW WITH |
| | CLEAR OPENING AREA NO LESS THAN 4 SQUARE FEET (0.38 M2) |
| | AND WITH MINIMUM OPENING HEIGHT AND WIDTH OF 22 INCHES |
| | (559 MM) AND 20 INCHES (508 MM), RESPECTIVELY, WITH |
| | MAXIMUM SILL HEIGHT AT 44 INCHES (1118 MM) ABOVE THE |
| | FLOOR OR APPROVED PERMANENT ELEVATED AREA, SHALL BE |
| | ACCEPTED AS AN EMERGENCY ESCAPE AND RESCUE OPENING. |
| | PHOTOGRAPHS TAKEN BY THE ZONING DEPARTMENT INDICATE TWO |
| | A/C UNITS WITHIN THE WINDOWS, THE BEDROOM UNIT BLOCKS |
| | THE CLEAR OPENING REQUIRED BY EX BLDG CODE 912.4.1 EX # |
| | 7. |
| | |
| | 5) EX. BLDG CODE SEE COMMENT# 2 CHANGE OF OCCUPANCY AND |
| | COMPLIANCE WITH CHAPTERS 6,7 & 8. EX BLDG CODE 606.4 |
| | REPLACEMENT OF WINDOWS AND DOORS. THE REPLACEMENT OF |
| | GARAGE DOORS, EXTERIOR DOORS, SKYLIGHTS, OPERATIVE AND |
| | INOPERATIVE WINDOWS SHALL BE DESIGNED AND CONSTRUCTED |
| | TO COMPLY WITH CHAPT FBC- R613.5 |
| | FBC-R 613.5 WIND-BORNE DEBRIS PROTECTION. PROTECTION OF |
| | EXTERIOR WINDOWS, GLASS DOORS AND OTHER GLAZED AREAS |
| | SHALL BE IN ACCORDANCE WITH SECTION FBC-R301.2.1.2. |
| | |
| | FBC-R301.2.1.2 PROTECTION OF OPENINGS. WINDOWS IN |
| | BUILDINGS LOCATED IN WIND-BORNE DEBRIS REGIONS SHALL |
| | HAVE GLAZED OPENINGS PROTECTED FROM WIND-BORNE DEBRIS. |
| | GLAZED OPENING PROTECTION FOR WIND-BORNE DEBRIS SHALL |
| | MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST OF AN |
| | APPROVED IMPACT RESISTING STANDARD OR ASTM E 1996 AND |
| | ASTM E 1886, SSTD 12, ANSI/DASMA 115 (FOR GARAGE DOORS) |
| | OR TAS 201, 202 AND 203 OR AAMA 506 REFERENCED THEREIN. |
| | |
| | PRODUCT APPROVALS SUBMITTED ARE FOR A NON-IMPACT |
| | GLAZING, PLEASE SUBMIT OPENING PROTECTION PRODUCT |
| | APPROVALS. PROVIDE STORM PANEL INFORMATION WITH |
| | INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| | GLAZING. FBC 1609.1.4. |
| | |
| | FL BLD CODE 2004 SECTION 106.3.3, |
| | 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3. |
| | PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| | SCHEDULE SUMMARIZING & IDENTIFYING OPENING SIZES, STORY |
| | HEIGHTS, UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT |
| | STORM |
| | BAR REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT |
| | TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT |
| | APPLICATION |
| | TO FACILITATE PLAN REVIEW AND PERMIT ISSUANCE. |
| | |
| | 6) PLEASE PROVIDE A SURVEY OR SITE PLAN INDICATING THE |
| | LOCATION OF THE STRUCTURE???S BACK WALL AND DISTANCE TO |
| | THE PROPERTY LINE. EX. BUILD CODE 912.6 EXTERIOR WALL |
| | FIRE-RESISTANCE RATINGS. HAZARD CATEGORIES IN REGARD TO |
| | FIRE-RESISTANCE RATINGS OF EXTERIOR WALLS SHALL BE IN |
| | ACCORDANCE WITH TABLE 912.6. UTILITY # 4 LOWEST HAZARD |
| | TO A R-3 HAZARD LEVEL 3. |
| | 912.6.1 EXTERIOR WALL RATING FOR CHANGE OF OCCUPANCY |
| | CLASSIFICATION TO A HIGHER HAZARD CATEGORY. WHEN A |
| | CHANGE OF OCCUPANCY GROUP IS MADE TO A HIGHER HAZARD |
| | CATEGORY AS SHOWN IN TABLE 912.6, EXTERIOR WALLS SHALL |
| | HAVE FIRE RESISTANCE AND EXTERIOR OPENING PROTECTIVES |
| | AS REQUIRED BY THE FLORIDA BUILDING CODE, BUILDING . |
| | PLEASE REVIEW FBC-R |
| | TABLE 302.1. |
| | |
| | 7) EX BLDG CODE 808.1. MINIMUM REQUIREMENTS, |
| | ALTERATIONS MADE TO THIS CHAPTER SHALL |
| | COMPLY WITH THE REQUIREMENTS OF CHAPTER 13 OF THE |
| | FBC-B/ R. |
| | |
| | 8) PLEASE NOTE ZONINGS REQUIREMENTS TO OBTAIN THE |
| | PROPER MECHANICAL, PLUMBING & ELECTRICAL PERMITS FOR |
| | THE BACK BUILDING THAT IS UNDERGOING A CHANGE IN |
| | OCCUPANCY. |
| | CURRENTLY APPLIED FOR ARE A PLUMBING PERMIT 10090078 TO |
| | RESURFACE A SHOWER, REPLACE A SINK & TOILET IN SAME |
| | LOCATION, THIS APPLICATION DOES NOT INDICATE IF IT IS |
| | FOR THE FRONT OR REAR BUILDING NOR DOES IT PROVIDE ANY |
| | INFORMATION AS TO MAKE THE BACK UNIT CODE COMPLIANT. |
| | |
| | THE SECOND PERMIT APPLIED FOR IS A SEPARATE ELECTRICAL |
| | PERMIT TO COTTAGE IN REAR, 10090805. |
| | NO ELECTRICAL PERMIT HAS BEEN APPLIED FOR IN REGARDS TO |
| | THE CHANGE OF OCCUPANCY. |
| | |
| | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |
| | |
| | |
| | |
| | |