| 2010-09-13 11:43:53 | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | GYPSUM BOARDS IN SHOWERS & WATER CLOSETS |
| | 2509.1 WET AREAS. SHOWERS AND PUBLIC TOLIET WALLS SHALL |
| | CONFORM TO SECTION 1210.2 AND 1210.3. |
| | 2509.2 BASE FOR TILE. CEMENT, FIBER-CEMENT OR GLASS MAT |
| | GYPSUM BACKERS IN COMPLIANCE WITH |
| | ASTM C 1178-08 STANDARD SPECIFICATION |
| | FOR COATED GLASS MAT WATER-RESISTANT GYPSUM |
| | ASTM C 1288-99 STANDARD SPECIFICATION |
| | FOR DISCRETE NON- ASBESTOS FIBER-CEMENT INTERIOR |
| | SUBSTRATE SHEETS |
| | ASTM C 1325-08 STANDARD SPECIFICATION |
| | FOR NON-ASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS |
| | BACKER UNITS |
| | AND INSTALLED IN ACCORDANCE WITH MANUFACTURER |
| | RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE |
| | IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN |
| | SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD |
| | SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET |
| | COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH |
| | GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS. |
| | REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR |
| | WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN |
| | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840. |
| | |
| | |