| Plan Review Stops For Permit 10080852 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-14 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-13 |
Time |
14:23 |
Sent To |
PC |
|
| Notes |
| 2010-10-14 09:04:03 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- REVISE ENERGY CALCULATIONS: | | | A) REVISE WINDOW INFORMATION TO MATCH PLANS. | | | B) REVISE EXTERIOR WALL INSULATION R VALUE TO MATCH | | | PLANS. OR REVISE PLANS TO MATCH THE ENERGY | | | CALCULATIONS. | | | C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | D) REVISE THE ROOF TYPE SHOWN ON SHEET 2 OF 5 TO MATCH | | | PLANS. | | | E) REVISE TYPE OF DOOR TO MATCH SHOWN ON SHEET 3 OF 5 | | | TO MATCH PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-09-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-09-29 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-09-29 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2010-09-29 14:26:26 | RESIDENTIAL (R3) RENOVATION/ALTERATION BUILDING REVIEW | | | CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | N1100.3 OF CHAPTER 11 OF 2007 FLORIDA RESIDENTIAL CODE. | | | ***NOTE: PLEASE MAKE SURE CORRECT UPDATED FORM IS USED. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | | | | A) OVAL WINDOWS AS SHOWN ON PLANS. | | | | | | B) FRENCH DOOR WITH TRANSOM ABOVE AS SHOWN ON PLANS FOR | | | ENTRY DOORS. | | | | | | C) NEW COMPOSITE SHUTTERS. AND PROVIDE COMPLETE | | | INSTALLATION SCHEDULE. | | | | | | D) GARAGE DOOR. NOA 05-0912.11 SUBMITTED DOESN'T MEET | | | THE DESIGN PRESSURES THAT WERE CALCULATED BY THE | | | ENGINEER OF RECORD. AND, THIS NOA IS FOR AN 18'-0" WIDE | | | DOOR. NEED TO PROVIDE PRODUCT APPROVAL THAT MEETS THE | | | CALCULATED DESIGN PRESSURES AND WITH THE SIZE SPECIFIED | | | ON PLANS. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-10-07 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-10-07 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-09-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-09-30 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-09-30 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2010-09-30 15:22:48 | NEED TO HAVE PANEL SCHEDULE. | | | | | | PANEL IN GARAGE CAN NOT BE IN A STORAGE CLOSET | | | | | | REMODELED BEDROOM TO THE RIGHT OF THE FRONT DOOR SHALL | | | SHOW ALL OUTLETS AND SWITCHES FOR COMPLIANCE WITH THE | | | CODE | | | | | | JAKE LEAHY | | | 644-7291 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-14 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-06 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-09-30 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-09-01 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2010-09-01 10:08:19 | SENT TO R-7. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2010-10-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-13 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-13 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2010-10-13 16:55:30 | TALKED TO CHRISTOPHER BICKFORD (OWNER). AGREED THAT A/C | | | CONTRACTOR WILL SUBMIT OWN PLANS AND EQUIPMENT SIZING | | | CALCULATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-09-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-09-29 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-09-29 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-10-14 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-10-14 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-09-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-09-29 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-09-29 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2010-09-29 13:31:41 | RESIDENTIAL (R3) RENOVATION/ALTERATION PLUMBING REVIEW | | | CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- PROVIDE PLUMBING RISER DIAGRAM WITH COMPLETE | | | INFORMATION AS REQUIRED BY SEC. 106.3.5.4 OF CITY | | | AMENDMENTS TO FBC. PLUMBING RISER DIAGRAM SUBMITTED ON | | | SHEET P1 IS MISSING THE PLUMBING FIXTURES DRAINAGE PIPE | | | SIZES AND LOCATION OF CLEANOUTS AS REQUIRED BY SEC. | | | P3005 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-09-13 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-09-13 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-09-13 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|