Plan Review Details - Permit 10080842
| Plan Review Stops For Permit 10080842 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2010-09-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-09-13 |
Time |
08:46 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2010-09-13 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2010-09-13 08:47:53 | BUILDING PLAN REVIEW | | | PERMIT: 10080842 | | | ADD: 2475 MERCER AVE | | | CONT: NYC CONSTRUCTION | | | TEL: (561)282-8418 | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). | | | | | | SHEET A-2 DOOR SCHEDULE, DOOR# 5: 11-4.13.5 DOORWAY MIN | | | CLEAR WIDTH . DOORWAYS SHALL HAVE A MINIMUM CLEAR WIDTH | | | OF 32" WITH THE DOOR OPEN 90-DEGREES, MEASURED BETWEEN | | | THE FACE OF THE DOOR AND OPPOSITE STOP. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-09-07 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2010-09-07 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2010-09-07 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2010-09-07 16:19:08 | OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE | | | NUMBER PX3182 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2010-09-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-09-17 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-09-17 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2010-09-17 15:21:50 | 2475 MERCER AVENUE | | | PERMIT NUMBER 10080842 | | | OFFICE BUILD-OUT | | | | | | | | | 1. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER SYSTEM AND FIRE ALARM SYSTEM REMODELS. | | | | | | 2. TACTILE SIGNAGE REQUIRED AT EXIT DOOR. | | | | | | 3. THE INSTALLATION OF ANY SOFFITS SHALL NOT INTERFERE | | | WITH THE OPERATION OF ANY FIRE SPRINKLER HEADS. | | | | | | | | | APPROVED | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-09-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-09-17 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-09-01 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2010-09-01 08:34:01 | SENT TO B-9. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-09-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-09-10 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-09-10 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-09-13 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-09-13 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-09-13 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-09-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2010-09-15 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2010-09-15 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
|